Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT06271577
Other study ID # PRO-0013
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date March 12, 2024
Est. completion date December 2024

Study information

Verified date March 2024
Source AliveCor
Contact Clinical Research Associate
Phone 855-338-8800
Email kroohi730@alivecor.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

AliveCor (www.alivecor.com) has developed several electrocardiogram (ECG) devices that interface with iOS and Android smartphones and tablets via various Kardia apps. The current Kardia family of devices can measure single lead and six limb-lead ECGs, depending on the device. KardiaMobile, KardiaMobile 6L, and KardiaMobile Card have FDA clearance for ECG rhythm recording. A modified single-lead Kardia smartphone 12-lead ECG was previously validated in the multicenter ST LEUIS study for the diagnosis of ST-Segment Elevation Myocardial Infarction (STEMI) and Non-ST-Elevation Myocardial Infarction (NSTEMI). Recently, AliveCor developed a new device: AliveCor (AC) 12-lead (12L) ECG System to record simultaneously 4 leads of ECG and then generate complete 12-lead ECGs. A previous protocol at the University of Oklahoma involved 200 subjects with early prototypes of the AC 12L device with the specific aim to validate that it accurately generated 12-lead ECGs as compared to simultaneously acquired FDA-cleared 12-lead ECGs. The prototype version of the AliveCor 12L ECG System simultaneously measured four channels of ECG (leads I, II, V2, V4), calculated the remaining limb leads as is standard for 12-lead ECGs (Leads III, aVR, aVL, aVF) and synthesized the remaining 4 precordial ECG leads (V1, V3, V5, V6). This protocol will serve to validate the production version of the system against standard 12-Lead ECGs for the diagnosis of STEMI and NSTEMI in patients admitted to the Emergency Department or directly to the Cardiac Cath Lab for the evaluation of chest pain. It is anticipated that the waveforms for each of the 12 leads from the AC 12L ECG System will be highly correlated with the corresponding leads from the comparator commercially available 12-lead ECG devices used at participating sites. The purpose of this study is to clinically validate that the four-channel AC 12L ECG device can enable the diagnosis of STEMI and NSTEMI in a non-inferior manner to existing 12-lead ECG devices.


Recruitment information / eligibility

Status Recruiting
Enrollment 1000
Est. completion date December 2024
Est. primary completion date November 2024
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Male or female > 18 years of age. - Ability to understand and sign a written informed consent form, which must be obtained prior to initiation of any study procedures. - Symptoms of chest pain upon presentation at the Emergency Department of the participating institution. Exclusion Criteria: - Inability or refusal of the patient and/or the patient's legally acceptable representative to provide written informed consent for any reason. - Other conditions that in the opinion of the Lead Investigator may increase risk to the subject and/or compromise the quality of the clinical trial.

Study Design


Intervention

Device:
AliveCor 12-lead ECG
The primary objective of this study is to determine if the AliveCor 12-lead Smartphone ECG is an acceptable substitute for a standard 12-lead ECG in the identification of STEMI and NSTEMI.

Locations

Country Name City State
United States Mayo Clinic Rochester Minnesota

Sponsors (1)

Lead Sponsor Collaborator
AliveCor

Country where clinical trial is conducted

United States, 

References & Publications (1)

Muhlestein JB, Anderson JL, Bethea CF, Severance HW, Mentz RJ, Barsness GW, Barbagelata A, Albert D, Le VT, Bunch TJ, Yanowitz F, May HT, Chisum B, Ronnow BS, Muhlestein JB; Duke University Cooperative Cardiovascular Society (DUCCS) investigators. Feasibility of combining serial smartphone single-lead electrocardiograms for the diagnosis of ST-elevation myocardial infarction. Am Heart J. 2020 Mar;221:125-135. doi: 10.1016/j.ahj.2019.12.016. Epub 2019 Dec 27. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Inter-rater variability for Standard 12-lead ECG readings 30 seconds
Primary Inter-rater variability for AC 12L ECG readings 30 seconds
Primary Number of standard 12-lead ECG readings requiring a consensus consultation 30 seconds
Primary Number of AC 12L ECG readings requiring a consensus consultation 30 seconds
Primary Sensitivity of AC 12L ECGs requiring consensus consultation, compared to standard 12-lead ECG requiring consensus consultation, for the diagnosis of STEMI 30 seconds
Primary Specificity of AC 12L ECGs requiring consensus consultation, compared to standard 12-lead ECG requiring consensus consultation, for the diagnosis of STEMI 30 seconds
Primary Positive predictive value of AC 12L ECGs requiring consensus consultation, compared to standard 12-lead ECG requiring consensus consultation, for the diagnosis of STEMI 30 seconds
Primary Negative predictive power of the AC 12L ECGs requiring consensus consultation, compared to standard 12-lead ECG requiring consensus consultation, for the diagnosis of STEMI 30 seconds
Primary Mean subjective correlation score for AC 12L ECGs in which the standard 12-lead ECG diagnosis is STEMI 30 seconds
Primary Mean subjective correlation score for AC 12L ECGs in which the standard 12-lead ECG diagnosis is not STEMI 30 seconds
Primary Mean summative ST-segment elevation, summative ST-segment depression and summative ST-segment deviation for AC 12L ECGs compared to standard 12-lead ECGs 30 seconds
See also
  Status Clinical Trial Phase
Recruiting NCT05650307 - CV Imaging of Metabolic Interventions
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Recruiting NCT05654272 - Development of CIRC Technologies
Active, not recruiting NCT05896904 - Clinical Comparison of Patients With Transthyretin Cardiac Amyloidosis and Patients With Heart Failure With Reduced Ejection Fraction N/A
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Recruiting NCT05631275 - The Role of Bioimpedance Analysis in Patients With Chronic Heart Failure and Systolic Ventricular Dysfunction
Enrolling by invitation NCT05564572 - Randomized Implementation of Routine Patient-Reported Health Status Assessment Among Heart Failure Patients in Stanford Cardiology N/A
Enrolling by invitation NCT05009706 - Self-care in Older Frail Persons With Heart Failure Intervention N/A
Recruiting NCT04177199 - What is the Workload Burden Associated With Using the Triage HF+ Care Pathway?
Terminated NCT03615469 - Building Strength Through Rehabilitation for Heart Failure Patients (BISTRO-STUDY) N/A
Recruiting NCT06340048 - Epicardial Injection of hiPSC-CMs to Treat Severe Chronic Ischemic Heart Failure Phase 1/Phase 2
Recruiting NCT05679713 - Next-generation, Integrative, and Personalized Risk Assessment to Prevent Recurrent Heart Failure Events: the ORACLE Study
Completed NCT04254328 - The Effectiveness of Nintendo Wii Fit and Inspiratory Muscle Training in Older Patients With Heart Failure N/A
Completed NCT03549169 - Decision Making for the Management the Symptoms in Adults of Heart Failure N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Enrolling by invitation NCT05538611 - Effect Evaluation of Chain Quality Control Management on Patients With Heart Failure
Recruiting NCT04262830 - Cancer Therapy Effects on the Heart
Completed NCT06026683 - Conduction System Stimulation to Avoid Left Ventricle Dysfunction N/A
Withdrawn NCT03091998 - Subcu Administration of CD-NP in Heart Failure Patients With Left Ventricular Assist Device Support Phase 1
Recruiting NCT05564689 - Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy