Clinical Trials Logo

Clinical Trial Summary

Non-Contrast Computed Tomography (NCCT) of the head is the most common imaging method used to assess patients attending the Emergency Department (ED) with a wide range of significant neurological presentations including trauma, stroke, seizure and reduced consciousness. Rapid review of the images supports clinical decision-making including treatment and onward referral. Radiologists, those reporting scans, often have significant backlogs and are unable to prioritise abnormal images of patients with time critical abnormalities. Similarly, identification of normal scans would support patient turnover in ED with significant waits and pressure on resources. To address this problem, Qure.AI has worked to develop the market approved qER algorithm, which is a software program that can analyse CT head to identify presence of abnormalities supporting workflow prioritisation. This study will trial the software in 4 NHS hospitals across the UK to evaluate the ability of the software to reduce the turnaround time of reporting scans with abnormalities that need to be prioritised.


Clinical Trial Description

Study background: Emergency Departments (ED) across the UK are overburdened with increasing patient demand, radiology staff shortages and rising patient wait times. Head injuries are a frequent cause of emergency attendance in the UK with computed tomography(CT) scans usually the first imaging tests to diagnose head injuries and strokes. A report issued by National Institute of Health and Care Excellence (NICE), confirms that each year 1.4 million people attend emergency departments in England and Wales with head injury. Among the 200,000 patients admitted annually, one-fifth of them suffer from a Traumatic Brain Injury with skull fracture or evidence of brain damage. Head injury is the most common cause of death and disability in people up to the age of 40. Early detection and prompt treatment is vital to save lives and minimise risk of disability, according to the NICE guidelines of Head injury: assessment and early management. Head CT scans are the gold standard for diagnosing these and it is critical that these are performed and reported by Radiologists in line with NICE guidelines. The potential applications of AI in radiology go well beyond image analysis for diagnostic and prognostic opportunities. It is becoming increasingly clear that AI algorithms have the potential to improve productivity, operational efficiency, and accuracy in diagnostic radiology. AI tools are being developed to aide diagnosis and enhance processes at multiple point in the radiology workflow including: (a) protocolling the prioritised scan,(b) clinical decision support systems for detection of critical findings, (c) worklist priority adjustment via AI results, and (d) reducing turnaround time through worklist prioritisation and semiautomated structures reporting. The adoption of AI tools is dependent on the demonstration of a tangible effect on patient care and improvement in radiologist workflow. Thus, in this study, we aim to assess whether real-world implementation of an AI tool which augments (b), (c) and (d) of the imaging life cycle would affect turnaround times. qER medical device: qER, a CE Class II approved medical software device, detects, and localizes the presence of six target abnormalities - intracranial haemorrhage, cranial fracture, midline shift, mass effect, atrophy and hypodensities suggestive of infarcts in non-contrast Head-CT scans. A priority status is assigned if any one of the target abnormalities (intracranial haemorrhage, cranial fracture, midline shift or mass effect) is detected by the software, and the user will be able to view a single summary slice listing all the target abnormalities found by qER on the CT scan followed by all slices in scan with the overlay of above abnormalities localization. Alternately, if none of the target abnormalities are detected, the output will indicate that the software has analysed the image and identified no critical findings. qER reports are intended to support certified radiologists and/or licensed medical practitioners for clinical decision making. It is a support tool and, when used with original scans, can assist the clinician to improve efficiency, accuracy, and turnaround time in reading head CTs. It is not to be used to provide medical advice, determine treatment plan, or recommend a course of action to the patient. Study design: A multi-centre stepped wedged cluster randomised study will be conducted in 4 NHS hospitals over a 13-month period. Hospitals will be identified and initiated into the qER solution with a 30-day implementation period. The order in which sites will receive the qER intervention will be determined by computer-based randomisation. The stepped wedge design allows delivery of the intervention at an organisational level with evaluation of outcome measures at a patient level. Structuring the implementation through a staged activation in a random order provides important methodological advantages for both qualitative and quantitative elements of the study. The design allows control of adoption bias and adjust for time-based changes in the background patient characteristics at a patient level. All patients under this pathway would receive an AI reading, and no additional or different tests will be performed as a result of the AI findings. The turnaround time will be the interval between the time the scan was taken to the time when the final scan report becomes available and will be measured in minutes. When qER assistance is used for reporting Head-CT scans and if there is a difference between the output of the qER and the radiologist, the latter will be considered as final for further patient management. Primary objective: The primary objective is to assess if qER based reporting and triage significantly reduce turnaround time (TAT) of critical NCCT head reporting for patients attending the emergency department. Secondary objective(s): - To assess utility of qER to support emergency department pathways for patients requiring NCCT head and radiology reporting workflow. - To assess the safety of qER at identifying patients with critical findings on NCCT heads. - To evaluate the technical performance of qER. - To conduct a Heath Economic, cost utility analysis of qER. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06027411
Study type Observational [Patient Registry]
Source Guy's and St Thomas' NHS Foundation Trust
Contact Haris Shuaib, MSc
Phone 020 7188 7188
Email haris.shuaib@gstt.nhs.uk
Status Recruiting
Phase
Start date March 27, 2024
Completion date August 2024

See also
  Status Clinical Trial Phase
Recruiting NCT03993236 - Study on Rosuvastatin+Ezetimibe and Rosuvastatin for LDL-C Goal in Patients With Recent Ischemic Stroke Phase 4
Completed NCT04069767 - Innovative Physiotherapy in Stroke Rehabilitation N/A
Recruiting NCT06342206 - The Assessment of Acute /Chronic Phase in Patients With Ischemic Cerebral Stroke Using TCM Diagnostic Tools
Recruiting NCT03605381 - MORbidity PRevalence Estimate In StrokE
Enrolling by invitation NCT04956211 - Periodontal Treatment and Ischemic Stroke N/A
Active, not recruiting NCT05098236 - Effect of Visual Retraining on Visual Loss Following Visual Cortical Damage N/A
Completed NCT03942588 - High-intensity Interval Training After Stroke N/A
Recruiting NCT04949334 - Effects of Respiratory Muscle Training in Patients With Acute Ischemic Stroke N/A
Terminated NCT04095767 - Assessing Safety and Performance of the ANA Catheter System, Combined With a Stent Retriever in Acute Ischemic Stroke N/A
Not yet recruiting NCT06352086 - Understanding Visual Processing After Occipital Stroke
Withdrawn NCT04991038 - Clinical Investigation to Compare Safety and Efficacy of DAISE and Stent Retrievers for Thrombectomy In Acute Ischemic Stroke Patients N/A
Completed NCT01937182 - The Efficacy of Citalopram Treatment in Acute Stroke Phase 2
Completed NCT03649295 - Combined Conventional Speech Therapy and Functional Electrical Stimulation in Dysphagia Following Stroke N/A
Recruiting NCT05303649 - Effects of Neuronavigated Theta Burst Stimulation in Therapy of Post-stroke Aphasia N/A
Completed NCT04233515 - Use of Oral Anticoagulants and Symptoms in Patients With Atrial Fibrillation in Örebro County
Completed NCT05102877 - Sensory Versus Motor Level Neuromuscular Electrical Stimulation N/A
Completed NCT04089917 - A Study of the Use of the Q Aspiration Catheter to Remove Clot in Stroke Patients
Completed NCT05221112 - Effects of PNF Patterns Training on Trunk Balance, and Gait in Chronic Stroke Patients N/A
Not yet recruiting NCT05035953 - Thrombolysis Combined With Edaravone Dexborneol on Hemorrhagic Transformation for Acute Ischemic Stroke Phase 2
Completed NCT06326801 - Resistive Diaphragmatic Breathing Exercise With Pursed Lips Breathing Exercise in Sub-acute Stroke Patients N/A