View clinical trials related to Respiratory Aspiration.
Filter by:Aim and Objectives: The purpose of this study was to determine the effects of breathing exercises and virtual reality applications during pregnancy and labor on labor pain, duration, and birth satisfaction. Background: Conducted studies show that practices such as virtual reality have positive effects on labor. However, there is no study that compares the effects of breathing exercises with virtual reality applications on labor. Design: A randomized controlled experiment was conducted by the CONSORT guidelines. Methods: The study included 114 pregnant women (Breathing Exercise Group:39, Virtual Reality Group:37, Control Group:38). The research was carried out in two stages. In the first stage, for the experimental groups at the 36th-39th weeks of pregnancy, a 10-minute breathing exercise was performed 3 times a week using virtual reality glasses and a breathing exercise device. In the second stage of the study (when the cervical dilatation was 4 cm), the breathing exercise group was made breathing exercises again. The virtual reality group watched a 10-minute video with virtual reality glasses. Once the virtual reality glasses were removed from experimental groups Visual Analogue Scale was applied. Birth satisfaction was evaluated with the Birth Satisfaction Scale within the first 4 hours after the delivery was completed.
This study finds the effectiveness of inspiratory muscle threshold loading training among adults with hypertension. A sample of hypertensive subjects was divided into two groups - inspiratory muscle training (IMT) - group (inspiratory muscle training was prescribed) and sham-group (no load was prescribed during IMT). Both groups had training sessions comprising seven cycles of two minutes bouts of breathing counter to an inspiratory load, each bout parted by one minute of unloaded recovery. Treatment session was performed for three times per week for a total of six weeks. Measurement of each of the variables (blood pressure, resting heart rate (RHR), heart rate variability (HRV)) was taken at baseline and after the six-week intervention.
The investigators aim to determine if the modification of the end inspiratory pause (EIP) during mechanical ventilation adds benefit when applied to patients undergoing robotic surgery and who are ventilated under an individualized open lung approach (iOLA) strategy. The EIP is an adjustable parameter of volume controlled ventilation modes usually set as a percentage of the total inspiratory time. It represents the phase comprised between the moment in which the volume programmed in the ventilator has already been administered (which marks the end of the inspiratory flow), and the opening of the expiratory valve (which marks the beginning of expiration). The investigators will study whether modifications of the EIP produce variations in the "quantity" of the lung that participates in gas exchange (respiratory volume). To do so, the investigators will sequentially apply different EIP to participants (paired study). The investigators´ hypothesis is that increasing the EIP up to a level, may diminish the lung volume that does not participate in breathing (the physiological dead space- VDphys), thereby increasing the respiratory volume. To note: the VDphys includes the "conduction" volume, that represented by trachea, bronchi, et cetera, which is in charge of driving the "air" towards the respiratory zones, and the alveolar dead space (those zones of the respiratory volume that due to different reasons do not directly participate in gas exchange: alveoli ventilated but not perfused, areas of overdistension, etc. The investigators will measure dead volumes by mean of specific non-invasive monitoring (volumetric capnography) coupled to the anesthesia workstation, and the mechanics of lung and the distribution of the gas within it by means of electric impedance tomography, a non-invasive technique showing continuous images of patient's lung. The estimation of the respiratory volume will help the investigators to more precisely adjust the amount of oxygen and anesthetic gases that must be administered in function of patients´ gases consumption, a calculated parameter that is function of the respiratory volume and that will also be tested during the study. The investigators will also accurately measure patient oxygenation by means of arterial blood samples extracted from a radial artery catheter. Apart from sequential modifications in the EIP, the ventilation strategy applied to patients will be that used in the investigators´ usual practice (described below).
In this study, the investigators will evaluate whether the delivered fraction of oxygen (O2) and sevoflurane administered through a a closed circuit and calculated on the basis of the estimations of O2 consumption (VO2) and sevoflurane uptake (SEVOup) through the inspired-expired fraction gradients of both gases once subtracted the physiological dead space (VDphys), adequately fits the real gases consumption. All participants will be ventilated under a tailored open lung approach (tOLA) strategy.
In patients under general anesthesia, the oxygen level (FiO2) used in inspiration is usually adjusted by monitoring the peripheral oxygen saturation level (SpO2). As a non-invasive method, SpO2 monitoring is known as one of the required methods that can be used to adjust FiO2 and detect and treat hypoxemia. While SpO2 approaching 100% matches the value of 128 mmHg in arterial partial oxygen pressure (PaO2), in cases where PaO2 increases more, the investigators cannot follow this situation with SpO2 and cannot prevent hyperoxemia. As stated in the literature, hyperoxemia has positive effects in general anesthesia and intensive care, as well as negative effects such as increased inflammation, oxidative stress and ischemia-reperfusion. In addition, acute lung injury, development of atelectasis, increased mortality, and critical illness rates have been associated with hyperoxemia in many publications. The only way the investigators can use to measure the level of hyperoxemia seems to be arterial blood gas analysis, and this method limits the investigators use because it is invasive. The Oxygen Reserve Index (ORiā¢) (Masimo Corp., Irvine, CA, USA) is a variable related to real-time oxygenation reserve status in the mildly hyperoxemic range (approximately 100 - 200 mmHg PaO2). ORi can be defined as a multi-wavelength, noninvasive pulse co-oximetry sensor. ORi is a dimensionless index ranging from 0.00 (no reserve) to 1.00 (maximum reserve) depending on the oxygenation reserve status. There are very few studies in the literature using ORi to detect hyperoxemia. The investigators thought that if FiO2 levels used in preoxygenation, anesthesia maintenance and recovery stages in day surgeries were correlated with ORi levels, a threshold value could be determined for FiO2 levels during anesthesia stages in cases where invasive arterial blood gas could not be followed. This study aims to determine the relationship between SpO2, FiO2 and ORi during general anesthesia, to investigate the usefulness of ORi in determining the FiO2 threshold value during anesthesia stages as an indicator of hyperoxemia, and to investigate the effects of these values on the hemodynamics, recovery, agitation and nausea-vomiting states of the patients.
This is an open label, multicenter, safety and PK study comparing safety, efficacy, and pharmacokinetic (PK) levels of Tacrolimus Inhalation Powder in lung transplant patients that require reduced tacrolimus blood levels due to kidney toxicity. Part A of the study will consist of a 12 week safety, efficacy, and PK study. Part B of the study will be an optional safety extension following successful completion of the 12 week safety, efficacy, and PK study. Patients would have the option to continue Tacrolimus Inhalation Powder for up to 1 year, with a possibility to extend to 2 years depending on the results from Part A.
COVID-19 is an infectious disease caused by the SARS-CoV-2 virus, which had its first case identified in December 2019 in Wuhan, China. The disease can cause death and collapse in health systems, in addition to increasingly prevalent sequelae. Among the persistent symptoms presented by patients in the post-COVID-19 phase, we highlight the respiratory ones. The diaphragm - the main muscle of respiration - can also undergo structural and functional changes resulting from SARS-CoV-2 infection. This finding is related to some respiratory sequelae of the disease, such as severe myopathy of the diaphragm with weakness and decreased endurance of the inspiratory muscles, dyspnea, fatigue, and failure in ventilatory weaning. Considering that COVID-19 can affect the respiratory muscles of afflicted individuals, it is reasonable to assume that inspiratory muscle training should improve inspiratory muscle weakness and endurance, and the functional capacity of individuals who had symptomatic COVID-19. Objective: To evaluate the effect of inspiratory muscle training on inspiratory muscle strength and endurance and on the functional capacity of individuals afflicted by COVID-19. Methods: This controlled and randomized clinical trial will be conducted according to the guidelines of the Vila Velha University Ethics Committee (CEP-UVV). The sample will consist of individuals with a positive diagnosis for SARS-CoV-2 infection assessed by means of the reverse transcriptase reaction followed by the polymerase chain reaction (RT-PCR) and who have already undergone the period of active infection. These individuals will be invited to participate in the study as soon as they are evaluated by the cardiopulmonary rehabilitation service. Those who meet all the inclusion criteria, agree to participate, and sign the free and informed consent form (FICF), will be randomly assigned to two groups, the control group (CG, n = 21) and the treatment group (TG, n = 21). The initial evaluation will consist of anamnesis, measurement of indirect blood pressure, heart rate, and peripheral oxygen saturation by portable pulse oximeter, analysis of maximum inspiratory pressure (MIP), dynamic inspiratory muscle strength index (S-Index), and endurance of the inspiratory muscles - which will be collected using a digital training device (PowerBreathe KH2), in addition to functional assessment through the 1-minute sit-to-stand test. The reassessment will take place six weeks after the start of the program and the same data will be collected at the participants' homes. Both groups will undergo the rehabilitation protocol, consisting of muscle strengthening and aerobic training, with individual assessment of exercise intensity. The treated group will undergo inspiratory muscle training through linear pressure load, using the POWERbreathe Classic Medic® device to perform two sets of 30 repetitions daily for six weeks. The same physical therapist will oversee the training sessions of all patients. Statistical analysis: Data normality will be tested using the Shapiro-Wilk test. To analyze the differences between groups, we will use the t-test for parametric data and the Wilcoxon test for non-parametric data. The level of significance will be set at 5% (p < 0.05). Data will be analyzed using the SPSS 8.0 software and the results expressed as mean ± standard deviation or median and interquartile range.
Aim: This study aims to determine the effects of the deep breathing exercise and the 4-7-8 breathing technique applied to patients after bariatric surgery on their anxiety and quality of life. Materials and Methods: The study was conducted between January and June 2022 at Ankara Lokman Hekim Akay Hospital Endocrinology and Metabolic Diseases Clinic. The research was carried out using the pre-test post-test randomized controlled experimental research design with a control group. A total of 90 patients (30 patients in the deep breathing group, 30 patients in the 4-7-8 breathing group, and 30 patients in the control group) who met the research inclusion criteria were included in the study. While routine care was applied to the control group, 1 group was given deep breathing training, and the other group was given 4-7-8 breathing training. Personal Information Form, the Obesity-Specific Quality of Life Questionnaire, Status, and the State-Trait Anxiety Inventory were used for data collection. In the evaluation of the data, number, percentage, mean, standard deviation, Kolmogorov Smirnov test, chi- square, dependent samples t-test, ANOVA, Tukey's test, Pearson Correlation analysis, and Cronbach's alpha Reliability Coefficient were used.
Extubation failure (EF) is independently associated with excess mortality of critically ill patients. To avoid EF, critically ill patients being weaned from invasive mechanical ventilation (IMV) perform spontaneous breathing trial (SBT), which is the litmus test for determining the ability to breathe without a ventilator. Thus, the performance of the SBT during weaning from IMV to predict successful extubation is crucial. The investigators hypothesize that patients with EF increase arterial lactate concentration during SBT due to increased work of breathing and hypoxia. The aim of this study is to evaluate the performance of variation in arterial lactate concentration before and after SBT in predicting successful extubation in critically ill patients.
To measure the impact of a coaching program on the patient's health-related quality of life 15 months post-transplant (M15/R12).