View clinical trials related to Heart Diseases.
Filter by:This clinical investigation evaluates the feasibility of the Rodeo Micro Mapping Catheter in combination with cryoablation ssystem (sclerotherapy of muscle tissue of the heart by freezing) in patients with atrial fibrillation (permanent atrial fibrillation excepted). Further aims of this study are the evaluation of safety of the device and average procedure and fluoroscopy times.
Investigator-initiated, prospective, non-randomized, open label, non-interventional multicenter registry to evaluate current treatment of three major cardiovascular disease entities in clinical practice using a standardized variable-set of relevant covariates and outcome measures.
Transcatheter aortic valve implantation (TAVI) serves a growing spectrum of patients with symptomatic severe aortic stenosis (AS). Approximately 80% of surgical aortic valve replacements is performed using a bioprosthesis1. Durability of surgical bioprostheses varies based on the patient's age at the moment of implantation, type and size etc2. TAVI has become the preferred treatment for degenerated aortic bioprostheses in elderly patients3. The median time since index surgical aortic valve replacement (SAVR) and for bioprosthetic valve degeneration is typically 8 - 10 years4-6. TAVI in this setting has proven to have equally favorable results as in native aortic valves7. Balloon expandable8 and self-expanding9 transcatheter heart valves (THV) can be used in a degenerated bioprosthesis and each have specific assets and limitations. TAVI in a failed bioprosthesis can cause coronary obstruction, THV migration, paravalvular leakage and prosthesis patient mismatch. The SAPIEN-3 / Ultra and EVOLUT R/Pro are the 2 most commonly used THV platforms in contemporary clinical practice including treatment of failing surgical aortic bioprostheses. Objective: To compare TAVI with EVOLUT R/Pro vs. SAPIEN-3 / Ultra in terms of device success. Study design: International multi-center randomized study with 1:1 randomization to TAVI with SAPIEN-3 / Ultra or Evolut R/Pro. Study population: 440 patients with a failing surgical aortic bioprosthesis (aortic stenosis with or without aortic regurgitation) and selected for transfemoral TAVI by heart-team consensus. Investigational intervention: Transfemoral TAVI with SAPIEN-3 / Ultra or Evolut R/PRO Main study parameters/endpoints: 1. Primary endpoint is device success at 30 days Defined by - Absence of procedural mortality AND - Correct positioning of a single prosthetic heart valve into the proper anatomical location AND - Intended performance of the prosthetic heart valve (no severe prosthesis- patient mismatch and mean aortic valve gradient < 20 mmHg or peak velocity < 3 m/s, AND no moderate or severe prosthetic valve regurgitation). Severe prosthesis patient mismatch is defined by effective orifice area (EOAi) ≤0.65 cm2/m2 2. Safety endpoint at 1 year defined by the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems.
There is existing data in the literature that suggests an additional predictive value of three dimensional ECG with respect to the presence of electrical abnormalities and for an existing cardiac disease. Especially regarding patients who suffered from a myocardial infarction in the past (post MI patients), evidence has been provided for a potential association of 3D repolarisation abnormalities and incidence of sudden cardiac death (SCD). In addition, there is some vague evidence of so called 3D ECG and prediction of coronary artery disease. This 3D ECG device is using the technology of 3D ECG vector loops and is assessing the variability of these ECG vector loops in the 3-dimensional space. Based on these data, the parameters of 3D ECG are suggested to carry certain value to predict or to identify individuals already suffering from a cardiac disease or being at risk experiencing a cardiac event in the future. In this context we performed a preliminary study with 3D-ECG device in healthy volunteers evaluating the robustness of this method with respect to reproducibility, intra- and intra-observer variability which could be confirmed. We thus postulate that the 3D ECG technology might bear the potential to serve as a sufficient screening method for diagnosing cardiomyopathy in patients with an unknown heart failure etiology.
Neurally adjusted ventilatory assist (NAVA) is a new mode of mechanical ventilation that delivers ventilatory assist in proportion to neural effort. The investigators hope to compare the hemodynamic and pulmonary effect in children after surgical repair of congenital heart disease with right ventricular hypertrophic ventilated with Pressure control ventilation (PCV), Pressure support ventilation (PSV), and NAVA by a crossover study.
SOCRATES is part of Boston Scientific's (BSC) Post-market surveillance system. The implementation of such systems is mandatory per local regulations such as the Regulation '(EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on medical devices' or short Medical Device Regulation (MDR). The SOCRATES design is therefore based on the BSC's commitment as well as external regulatory requirements to proactively and systematically gather, record and analyze relevant data on the quality, performance and safety of devices throughout their entire lifetime.
Percutaneous coronary intervention is currently one of the effective methods for the treatment of ACS. Unfortunately, the incidence of ISR is as high as 10%-20% at 3-6 months after PCI. So it is necessary to identify the potential risk factors to provide evidence for the prevention of ISR. Current research shows that anxiety and depression are related to the increased risk of major adverse cardiac events and mortality in patients with acute myocardial infarction. But there remains a relative paucity of evidence for the association between anxiety and depression and in-stent restenosis (ISR) .So a retrospective cohort study was conducted in the first hospital of Qinhuangdao in 2015-2020. The patients who underwent coronary angiography 1 year after PCI in our hospital from January 2015 to September 2020 were selected. Patients were divided into ISR and non-ISR groups depending on the follow-up coronary angiography results. Logistic regression model was utilized for analyzing the association of depression and anxiety with the in-stent restenosis (ISR) after PCI.
Establish a pulmonary hypertension registry and biorepository to lead towards a further understanding of the disease.
The study aims to test whether platelet transfusion or fibrinogen concentrate is the most effective treatment of intraoperative bleeding, when performing open heart surgery with cardiopulmonary bypass on children with congenital heart defects.
This randomized controlled trial will evaluate whether use of the PulsePoint system increases bystander CPR or defibrillator use compared to standard dispatch procedures in patients who suffer non-traumatic, out-of-hospital cardiac arrest in a public location. Half of all suspected cardiac arrest 9-1-1 calls in a public location will receive PulsePoint alerts (treatment arm). The other half of this eligible patient cohort will receive standard dispatch procedures (control arm).