There are about 9403 clinical studies being (or have been) conducted in Switzerland. The country of the clinical trial is determined by the location of where the clinical research is being studied. Most studies are often held in multiple locations & countries.
Background: In patients with severe sepsis and septic shock early aggressive volume replacement reduced mortality. Standard infusion therapy consists of crystalloid infusions. The role of modern, low molecular weight, starch preparations and their influence on the course of disease is not determined yet. Hypothesis: The purpose of this study is to determine wether initial infusion therapy with Hydroxyethylstarch and Ringer's lactate reduces in septic patients reduces Intensive Care Unit and hospital length of stay without impairment of renal function Design: Double-blind, randomized, controlled monocentric study Setting: Intensive Care Units of a University Hospital Patients: 240 consecutive patients with sepsis, severe sepsis and septic shock Intervention: Volume therapy with Ringer's lactate and saline or hydroxy-ethyl starch (MW 130, substitution 0.4) in the first five days of intensive care treatment. Parameter: - Intensive Care length of stay - Hospital length of stay - Mortality - Kidney function Statistics: Mann-Whitney test for non-parametric data like intensive care length of stay. Unpaired t-Test for kidney function parameters. Study withdrawal: Significant impairment of kidney function parameters in the hydroxy-ethyl starch group
People who have a dangerously fast heart beat, or whose heart is at risk of stopping beating, may be in need of an electronic device called an implantable cardioverter defibrillator (ICD). An ICD is implanted surgically just under the skin in the upper chest area and it sends a strong electrical impulse, or shock, to the heart to return it to a normal rhythm. The purpose of this study was to evaluate the safety and efficacy of the EnTrust ICD device. A feature of this device allows it to send small, painless electrical impulses (Anti-tachycardia pacing or ATP) to the heart instead of shocking it out of a rhythm that is too fast. Stopping a dangerous heart rhythm this way does not cause any pain whereas a shock to the heart can feel like a punch in the chest. This device also allows the heart to beat on its own when it can and helping it (by pacing, or sending it electrical signals) when it needs help. This feature is important because previously studies have shown that pacing the heart too often can increase the risk for heart failure or for atrial fibrillation (having too rapid of heart beats in the atrium). This study is now complete and the device has since been approved by the FDA.
The aim of this trial is to evaluate whether the prophylactic use of Defibrotide (DF) in pediatric patients (age less than 18 years) undergoing stem cell transplantation and who are at high risk of developing hepatic Veno-occlusive Disease (VOD) will have an impact on the incidence and severity of the disease. Patients will be randomly assigned to one of two treatment arms: Those allocated to the Prophylactic Arm will receive the study drug (Defibrotide) from the day of conditioning onwards. Patients allocated to the Control Arm will receive the study drug (Defibrotide) from the day that VOD is diagnosed.
The primary objective of the study is to assess the activity of fulvestrant in postmenopausal women with advanced breast cancer failing treatment with non-steroidal or steroidal aromatase inhibitors by estimating the Clinical Benefit Rate
Since the first placement of a totally implantable venous access port (TIVAP) by Niederhuber et al in 1982 its application to provide long-term central venous access has dramatically increased. These systems have dramatically simplified the administration of chemotherapy and parenteral nutrition as well as the repetitive collection of blood samples. Initial retrospective studies have focused on the complications associated with different implantation techniques. Subsequently, major attention has been payed to the comparison of distinct types of TIVAPs. To date a variety of approved port systems are available. These devices can be either implanted using the Seldinger technique or by venous cut-down of the cephalic vein Despite the global use of these established implantation procedures prospective, randomized trials directly comparing these two approaches are still lacking. So, the choice, which technique to use is left to the surgeon's preference. The aim of this study is to directly compare the Seldinger technique versus cephalic vein cut down for placement of TIVAPs in respect of implantation success rate, operation time and perioperative morbidity.
Eosinophilic Esophagitis (EE) is a chronic, T-helper 2 cell (TH2) - type inflammatory disorder of the esophagus with a rapidly increasing prevalence. Studies analyzing the natural course of EE provide strong evidence, that the chronic inflammation leads to irreversible structural changes in the esophagus with a loss of the mucosal elasticity and a fibrosis of the sub-epithelial esophageal layers with a concomitant risk of impairment in function. Treatment strategies in chronic inflammations have, in general, two main goals: 1) Relief of symptoms and 2) Prevention of long-term damage of the affected organ. Until now, the treatment of EE is still controversial. Standard recommendations for therapy of this chronic eosinophilic inflammation include dilation, systemic or topical corticosteroids and leukotriene antagonists. Several of these reports demonstrate, that topical corticosteroids may be effective for symptom control as well as for down-regulating the local inflammation. Furthermore it has been demonstrated, that treatment with topical corticosteroids is as effective as oral prednisone. However, the majority of therapeutic recommendations are based on clinical observations, case reports or small case series. The purpose of this study is the evaluation of the efficacy and the safety of a monotherapy with a topical corticosteroid as short-term induction-treatment and as long-term, maintenance-treatment compared with placebo, in the treatment of adult patients with active EE.
The main purpose of the Product Performance Report (formerly referred to as System Longevity Study) is to evaluate long-term performance of Medtronic market-released cardiac rhythm products by analyzing product survival probabilities.
IBIS-2 is a study using SB-480848 versus placebo in subjects with angiographically documented coronary heart disease. Endpoints include coronary imaging, endothelial function, biomarkers, safety and tolerability.
The overall aim of this trial, which is called STAMPEDE, is to assess novel approaches for the treatment of men with prostate cancer who are starting long-term ADT for the first time, termed hormone-naïve prostate cancer. This trial aims to see if we can improve the way in which prostate cancer is currently managed, either by adding new treatments to the standard approach or by modifying the type of hormone therapy aiming to improve quality-of-life by reducing the side effects of treatment. Each new treatment approach is compared against a control arm receiving the current standard treatments. We aim to identify treatment strategies that enable men to live longer, or as long but with an improved quality-of-life, as well as offering value for money for the health service. Since opening to accrual in Oct-2005, the trial has tested many ways of treating prostate cancer and some results are now already known. More than 10,000 men will join the trial with answers becoming available throughout the trial. New patients joining the trial from Protocol version 17.0 onwards (activated in December 2018) may be eligible to join one of two treatment comparisons, metformin (treatment group K; the "metformin comparison") and transdermal oestradiol (treatment group L; the "transdermal oestradiol comparison"). A computer program will be used to allocate which treatment each participant receives, using a chance process. Summary of the research arms in STAMPEDE trial platform Summary of research treatment groups currently open to recruitment (June 2017) 1. Metformin (Arm K): This anti-diabetic medication is proposed to have both anti-cancer effects and may help prevent the adverse metabolic effects of long-term ADT. STAMPEDE will investigate whether adding metformin to the current standard-of-care for non-diabetic men can improve all-cause survival. 2. Transdermal oestradiol (Arm L): This is an alternative form of hormone treatment which has been shown to suppress testosterone as effectively as standard ADT and avoid some of the side-effects. It may also help to avoid the adverse metabolic effects and fatigue and therefore improve overall quality of life compared with standard forms of ADT. STAMPEDE will investigate whether transdermal oestradiol can treat the cancer as well as current standard forms of ADT. 3. Control group (Arm A): Patients allocated to this group receive the current standard-of-care ADT +/- RT +/- docetaxel.
Heart failure is a progressive disease that decreases the pumping action of the heart. This may cause a backup of fluid in the heart and may result in heart beat changes. When there are changes in the heart beat sometimes an implantable heart device is used to control the rate and rhythm of the heart beat. In certain heart failure cases, when the two lower chambers of the heart no longer beat in a coordinated manner, cardiac resynchronization therapy may be prescribed. People who have a dangerously fast heart beat, or whose heart is at risk of stopping beating, may be in need of an electronic device called an implantable cardioverter defibrillator (ICD). Atrial tachyarrhythmia (AT) is the name for rapid beats in the upper chambers of the heart. People with AT may experience symptoms such as heart palpitations (a racing or pounding feeling in the chest), shortness of breath, dizziness, fatigue or weakness. The purpose of this study is to study an investigational implantable device containing Cardiac Resynchronization Therapy (CRT) and Implantable Cardioverter Defibrillator (ICD) therapies (CRT+ICD device) in subjects who are at significant risk of developing atrial tachyarrhythmias.