Clinical Trials Logo

Clinical Trial Summary

Since Gruntzig successfully performed percutaneous coronary balloon angioplasty in 1977, percutaneous coronary intervention has developed rapidly. From bare metal stents to drug-eluting stents (DES), the symptoms and prognosis of patients with coronary heart disease (CHD) have been greatly improved. Although DES has reduced the probability of in-stent restenosis (ISR) and thrombosis compared with BMS since its clinical application, it can not completely solve this problem. Even if the new generation of DES requires revascularization, the incidence of ISR is still as high as 5%-10%. DES treatment is associated with delayed endothelial healing, late acquired poor stent adherence and new atherosclerosis, which lead to late ISR and thrombosis. In addition, DES is still not ideal for the treatment of small vessel disease, diffuse long lesion and bifurcation lesion. Therefore, drug coated balloon (DCB) has attracted people's attention. Balloon-loaded antiproliferative drugs can fully release the drugs to the vascular wall during balloon dilation, which can inhibit the restenosis process from the beginning of injury, and show good efficacy and safety in some specific lesions. Many clinical studies have shown that DCB has good efficacy and safety in some specific lesions (ISR, small vessel disease, bifurcation disease, in situ lesion). Especially in the treatment of ISR, researchers believe that its efficacy is not inferior to DES, and it has the advantage of non-metal residues. Quantitative flow ratio (QFR) is the second generation FFR detection method based on angiographic images. The diagnostic accuracy of QFR 0.80 for myocardial ischemic stenosis was 92.7%. Compared with QCA, the positive predictive value and negative predictive value of QFR were also significantly better than those of QCA. The latest FAVOR II results also confirm that QFR is more sensitive and specific in diagnosing myocardial ischemia caused by coronary artery stenosis than QCA, and confirm the feasibility of using QFR online in catheter lab to evaluate the functional significance of coronary artery critical lesions. However, there is no report on the treatment of de novo lesions in patients with coronary heart disease by DCB under the guidance of QFR. The aim of this study was to evaluate the safety and efficacy of drug balloon therapy for de novo lesions in patients with CHD under the guidance of QFR compared with DES implantation.


Clinical Trial Description

The current study is designed as a multicenter, randomized and prospective study aiming to evaluate the safety and efficacy of drug balloon therapy for de novo lesions in patients with CHD under the guidance of QFR compared with DES implantation. Based on previous study, the incidence rate of target lesion failure is 5%-10% in patients with CHD undergoing DES implantation. And in the investigators study the expected incidence rate of target lesion failure is up to 5.0 % in patients with CHD after treatment with DCB. Moreover, the investigators estimated 10% loss follow-up of these patients in each arm. As a result, a total of 220 patients with CHD were required, and with 110 patients per group as a ratio of 1:1 randomization. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04104854
Study type Interventional
Source Nanjing First Hospital, Nanjing Medical University
Contact Fei Ye, MD
Phone +86 13327823900
Email doctor_ye@126.com
Status Not yet recruiting
Phase N/A
Start date March 1, 2024
Completion date December 1, 2026

See also
  Status Clinical Trial Phase
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Completed NCT05088291 - Application of a New X-ray Protective Device in Coronary Interventional Therapy
Completed NCT03076801 - Does Choral Singing Help imprOve Stress in Patients With Ischemic HeaRt Disease? N/A
Completed NCT04584645 - A Digital Flu Intervention for People With Cardiovascular Conditions N/A
Not yet recruiting NCT04995159 - Optimized Antiplatelet Therapy in Patients With CHD After Implantation of NeoVas™ BRS System N/A
Recruiting NCT02967718 - Innovation Research of Differentiation and Treatment Methods Based on CHD Phlegm and Blood Stasis Syndrome N/A
Completed NCT02888652 - Study on the Registration of Coronary Heart Disease Patients Undergoing PCI
Completed NCT02163044 - The Hellenic Postprandial Lipemia Study (HPLS)
Terminated NCT02045134 - Supplementation With Polyphenol-Rich Foods and Atrial Fibrillation After a Cardiac Surgery N/A
Active, not recruiting NCT02244853 - Heart Rate and Cardiovascular Diseases Prognosis in People With Stable Coronary Artery Disease N/A
Terminated NCT01906957 - Cognition and Exercise Training N/A
Completed NCT01920009 - Impact of Motivational Interviews Within Pharmacy Care Upon Adherence to Cardiovascular Medicines N/A
Completed NCT02440893 - Understanding the Effect of Metformin on Corus CAD (or ASGES)
Completed NCT02753829 - Home-based Cardiovascular Rehabilitation, Maintenance Phase, in Subjects With Coronary Artery Disease N/A
Completed NCT01826552 - Comparison of the Angiographic Result of the Orsiro Hybrid Stent With Resolute Integrity Stent Phase 4
Recruiting NCT01689688 - Healing Response to Everolimus-eluting Stent Implantation; Serial Assessment With opticaL Coherence Tomography N/A
Completed NCT01779401 - Clopidogrel Response Evaluation and AnTi-Platelet InterVEntion in High Thrombotic Risk PCI Patients N/A
Recruiting NCT01456364 - Intracoronary Stenting and Antithrombotic Regimen: ADjusting Antiplatelet Treatment in PatienTs Based on Platelet Function Testing Phase 4
Recruiting NCT01462799 - COR-PRIM: Problem-based Learning (PBL) After Coronary Heart Disease (CHD) - Long-term Evaluation in Primary Care of Self-care N/A
Completed NCT01486030 - Effect of Exercise Stress Testing on Peripheral Gene Expression Using Corus CAD (or ASGES) Diagnostic Test