Clinical Trials Logo

Sleep Apnea, Obstructive clinical trials

View clinical trials related to Sleep Apnea, Obstructive.

Filter by:

NCT ID: NCT03230877 Completed - Clinical trials for Obstructive Sleep Apnea

The Evaluation of a Full Face Mask Seal for the Treatment of Obstructive Sleep Apnea

Start date: September 2, 2017
Phase:
Study type: Interventional

The investigation is a prospective, randomized, single blinded, crossover study. The investigation is designed to evaluate the performance, comfort and ease of use of the F&P Trial Full Face Mask Seal amongst Obstructive Sleep Apnea (OSA) participants. A total number of 40-45 OSA participants will be recruited for the trial by the investigation site

NCT ID: NCT03230110 Completed - Hypertension Clinical Trials

OSA in Pregnant Women With Chronic HTN

OSA-CHTN
Start date: June 16, 2017
Phase:
Study type: Observational

The purpose of this study is to identify whether pregnant women with chronic hypertension are at significantly higher risk of having undiagnosed OSA and should be routinely screened with home sleep tests. The investigators will recruit 120 pregnant subjects between 10-20 weeks gestation from the Duke High Risk Obstetrics Clinic over a 20-month period. They will be enrolled into one of two groups: 1) chronic hypertension (on medication or hypertensive blood pressures documented at 3 clinic visits); 2) normal blood pressure, and not on any treatment for chronic HTN and no history of chronic HTN, and matched for BMI (+/- 3 kg/m2) with the chronic HTN group. The two groups will be matched for BMI to control for the effect of obesity on OSA diagnosis and cHTN. The primary hypothesis, that OSA prevalence differs between patients with chronic HTN and normotensive controls, will be assessed with a two-group two-sided Fisher's exact test. A Fisher's exact test with a 0.05 two-sided significance level will have 92% power to detect the difference between a normotensive OSA rate of 0.10 and a chronic hypertensive OSA rate of 0.40 when the sample size in each group is 50. There are no risks associated with the use of the home sleep test device, but subjects that have a severe latex allergy should not participate, as the device

NCT ID: NCT03226652 Completed - Heart Failure Clinical Trials

Heart Function in Patients Assessed for Sleep Apnoea

Start date: July 24, 2017
Phase:
Study type: Observational

This study aims to determine the prevalence and prognosis of heart failure with preserved ejection function (HFpEF) among patients being assessed for sleep disordered breathing (SDB).

NCT ID: NCT03223467 Completed - Obesity Clinical Trials

Obstructive Sleep Apnea, Predictors and Bariatric Surgery

Start date: January 4, 2012
Phase: N/A
Study type: Interventional

Obstructive sleep apnea is defined as a repetitive collapse of the pharynx during sleep (Malhotra, et al. 2012) which cases intermittent hypoxia. Snoring, witnessed apnea, fatigue and morning headache are symptoms of the disease which has severe health effect (Malhotra. et al. 2012) including increased mortality risk (Ensrud. et al. 2012) and effects on quality of life (Kuhn. et al. 2017). Obesity, male sex and age are all risk factors for obstructive sleep apnea (Schwartz. et al. 2010, Edwards. et al. 2010) . Bariatric surgery is known to be a good treatment to achieve a sustained weight loss but the long term effects of bariatric treatment of obstructive sleep apnea is not well studied. The aim of this study is therefore to study the long effects of bariatric surgery as a treatment for obstructive sleep apnea and to find predictors that can be used to predict the severity of the disease.

NCT ID: NCT03221205 Completed - Obesity Clinical Trials

Effect of CPAP on Myocardial Dysfunction in Type 2 Diabetes Mellitus and Obstructive Sleep Apnea Patients

Start date: October 15, 2014
Phase: N/A
Study type: Interventional

This study evaluates the effect of the use of nasal CPAP in the cardiac function, measured by strain and TEI index, in patients with type 2 diabetes mellitus, obstructive sleep apnea and obesity. In order to do so, 76 patients will be studied, half will use sham CPAP and half will use therapeutic CPAP for three months, with echocardiogram, laboratory studies, ambulatory monitoring of arterial tension and sleep study before and after CPAP use.

NCT ID: NCT03219749 Completed - Obesity Clinical Trials

Sleep Apnea, Cardiovascular and Exercise Study

Start date: January 15, 2017
Phase: N/A
Study type: Interventional

Obstructive sleep apnea (OSA) results in vascular dysfunction, which increases the risk of cardiovascular disease. In contrast, exercise confers cardioprotection through improvements in vascular health. This proposal evaluates whether the beneficial effects of exercise on vascular function are attenuated in obese individuals suffering from untreated OSA.

NCT ID: NCT03219034 Completed - Clinical trials for Obstructive Sleep Apnea

Trial on Oral Appliance Design for Improving Upper Airway Function and Sleep Quality

Start date: October 10, 2017
Phase: N/A
Study type: Interventional

This study will compare the effectiveness of the two leading oral appliances (OAs) designs for the treatment of severe obstructive sleep apnea in overweight adults. The effectiveness of OAs has come under question since different designs are combined in evaluating treatment efficacy, for example when comparing them to continuous positive airway pressure Due to the wide range of reported efficacy (53 to 90%), it is of great value to identify the most effective design to guide sleep practitioners and patients.

NCT ID: NCT03217383 Completed - Sleep Apnea Clinical Trials

Predictive Accuracy of MATRx Plus in Identifying Favorable Candidates for Oral Appliance Therapy

Start date: July 10, 2017
Phase: N/A
Study type: Interventional

Obstructive sleep apnea (OSA) is a common disease that is largely un-diagnosed and untreated. Standard treatment for obstructive sleep apnea, nasal continuous positive airway pressure (CPAP), entails use of a nose mask to deliver positive pressure which dilates the pharynx and eliminates obstruction. This therapy is highly efficacious and benign but is associated with low adherence, particularly in non-sleepy apneics with disease of mild and moderate severity. The principal alternative to CPAP therapy is oral appliance (OA) therapy in which a custom made mandibular advancement splint (MAS) is used to protrude the mandible during sleep, thereby opening the pharyngeal airway. OA therapy, while preferred and well accepted by most participants, is not uniformly efficacious. Additionally, uncertainty regarding the patient's response to OAT and the effective target mandibular position can lead to a significant time span between diagnosis and initiation of effective treatment. Furthermore, knowledge of the effective target mandibular position supports the use of new OA design and manufacturing processes that can further reduce the time and cost in delivering the therapy. Zephyr Sleep Technologies (the Sponsor) has developed a method of identifying OAT responsive participants and their efficacious mandibular protrusion. Recently, Zephyr Sleep Technologies developed a portable device that avoids this requirement and can be used in a multi-night test in the home. Using a feedback controlled mandibular positioner (FCMP), the device measures and analyzes respiratory airflow and oxygen saturation and makes decisions in real-time about moving the mandible. The FCMP device was tested in a blinded, bi-phase clinical study in which participants with mild-to-severe sleep apnea (n=202) underwent two full-night studies in the home. Data from phase 1 were used to develop a predictive method, and data from phase 2 were used to prospectively test the accuracy of the predictive method. An efficacious mandibular position was also predicted, and each participant was treated with a custom oral appliance set to that position. Data from both phases were used to evaluate the feasibility of use of the device in the home. A random forest machine learning system was used to develop and test the predictive method. The overall oral appliance success rate was 76% for phase 1 and 71% for phase 2. The overall predictive accuracy was 88%. Values for sensitivity and specificity were 85% and 93%, respectively. Positive and negative predictive values were 97% and 72%, respectively. The effective target protrusive position was identified in 86% of cases. The studies were conducted independently by the participants in their homes, though due to limitations in the early prototype design, a clinical coordinator visited the home to set up the equipment prior to each night of study. No significant problems were encountered, and no significant risks were identified. The results of the clinical trial show that the auto-titrating mandibular positioner is suitable for use in the home and accurately predicts OAT outcome as well as target protrusive position. Based on the results of this study, Zephyr developed a commercially available device which has been approved for sale in Canada (Health Canada device license #97614). The device, branded MATRx plus, functions as both a sleep recorder as well as a home-based system to select patients for oral appliance therapy. This commercially available device is currently being used in three separate usability trials to quantify the usability of the device and the benefits of an improved workflow through adoption of the new technology in a dental practice. Evidence has recently appeared to indicate that the change in pharyngeal volume caused by protrusion of the mandible, measured while awake, correlates with the change in apnea-hypopnea index (AHI) achieved by OAT, measured while asleep. This is the first convincing evidence that an awake measurement of the pharyngeal airway correlates with the improvement in respiratory status during sleep induced by an oral appliance. The implication is that a simple conebeam CT of the pharynx can predict outcome with OAT. Accordingly, we shall carry out conebeam CTs in the research protocol, both at rest position of the mandible and at 90% of maximal protrusion. The purpose of this study is to test whether the predictive accuracy of the FCMP in the home environment is improved by the commercial design and whether patients predicted to be suitable for oral appliance therapy have long term adherence.

NCT ID: NCT03215121 Completed - Clinical trials for Obstructive Sleep Apnea

Mask Study: One-handed vs. Two Handed Technique in Children

Start date: April 1, 2018
Phase: N/A
Study type: Interventional

During induction of anesthesia in children, the investigators have observed significant variability in mask holding technique at our institution among different anesthesia practitioners. Some hold the face mask using one hand and others use two hands. The aim of our study is to comparatively evaluate the extent of airway obstruction in children whilst anesthetic mask is held with one hand with jaw thrust versus mask held using two hands with chin lift by anesthesia provider during induction of anesthesia in children.

NCT ID: NCT03210142 Completed - Clinical trials for Sleep Apnea, Obstructive

Minimally Invasive Hypoglossal Nerve Stimulation Study (Lingual Study)

Lingual
Start date: June 23, 2017
Phase: N/A
Study type: Interventional

The purpose of this study is to assess the effect of Transvenous Hypoglossal Nerve Stimulation (tHGNS) on tongue position in the upper airway. Activation of the HGN will cause contraction of the genioglossus muscle, which will move the tongue forward, opening the upper-airway and reducing apnea-hypopnea events in patients with Obstructive Sleep Apnea (OSA). A transvenous approach will be less risky and traumatic than current HGNS systems that require an open surgical approach to wrap a cuff electrode around the HGN.