View clinical trials related to Knee Disease.
Filter by:EQ-5D is one of the most commonly employed patient-reported outcome (PRO) measures. It is included in many of the Swedish National Quality Registers (NQRs). EQ-5D health states are usually summarized using 'values' obtained from healthy members of the general public. However an alternative - which remains to be studied in detail - is the potential to use patients' self-reported overall health on the visual analogue scale as a means of capturing experience-based values. The overall aim of this project is to increase knowledge on the potential applicability of EQ VAS as a health state valuation method through assessment of its variability across and within patient groups and compared with that of the general population in Sweden. Data on nearly 700,000 patients from 12 NQRs covering a variety of diseases/conditions and from the general population will be analysed. Longitudinal studies of PROs among different patient groups will be conducted at baseline/first visit and 1-year follow-up. Descriptive analyses comparing EQ-5D health states and observed self-assessed EQ VAS within and across registers will be performed. Comparisons of the change in health state and observed EQ VAS values over one year will also be made. Regression models will be used to assess whether EQ-5D dimensions predict observed EQ VAS values to investigate patient value sets in each NQR. These will be compared across the patient groups and with the existing Swedish experience-based VAS and time trade-off (TTO) value sets obtained from the general population. This research project will provide information on the variation among different patient groups in terms of self-reported health status through EQ VAS and comparison with the general population. Knowledge on the relative importance of different dimensions of the EQ-5D to different patient groups as well as the general population will be gained in this project. The possibility of getting value sets based on patients' self-reported EQ VAS values and their comparison with value sets from experience-based general population studies will be discussed.
This is a prospective, randomized, controlled study. The purpose of this study is to assess functional and clinical changes among patients with symptomatic knee OA treated with intra-articular injections of autologous adipose tissue or PRP and to compare the efficacy of both therapeutic methods. We hypothesize that adipose tissue injections will improve patients' quality of life and functional status and will decrease pain level significantly more than PRP injections. In addition to the functional tests and muscle strength measurement, the patient reported outcome measures (PROMs) of the knee joint function and quality of life will be used to assess each participant. The same inclusion criteria have been established for an Experimental Group (subjects treated with autologous fat tissue) and a Control Group (subjects treated with PRP). Those criteria consist of: symptomatic knee OA, age between 45 and 65 y.o., Kellgren- Lawrence grades I - III OA, no or minimal positive effects of previous conservative treatment (rehabilitation, hyaluronic acid injections, steroid injections). Those patients who meet inclusion criteria will be allocated to Fat Tissue Group or PRP Group randomly. Patients will be assessed five times: before treatment and 1, 3, 6 and 12 months after the treatment. The PROMs consist of the four questionnaires: The Knee injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee 2000 (IKDC 2000), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) (21,22), the Health Questionnaire EQ- 5D- 5L. Moreover, three functional tests will be performed to assess patient's functional status: The Timed Up and Go Test (TUG), The 5 Times Sit to Stand Test (5xSTS), The 10m Walk Test (10mWT). To assess strength parameters of the knee flexors and extensors the Maximal Voluntary Isometric Contraction (MVIC) will be measured. Each test will be supervised by the same one physiotherapist to avoid any interexaminer bias and discrepancies during testing.
This study is a post-market clinical follow-up conducted in order to collect long-term data on security and performance of the FHK asymetrique prosthesis, which is intended to be implanted in case of total knee replacement, when used in real life conditions according to the instructions for use.
The ultrasound-guided selective blockade of the saphenous nerve in the adductor canal provides effective analgesia and reduces postoperative pain in patients undergoing arthroscopic medial meniscectomy. Selective blockade of the saphenous nerve in the adductor canal provides effective analgesia without quadriceps muscle weakness. It has been shown that the adductor canal block (ACB) block increases the spread of local anesthetics in a distal and proximal way. Therefore, the proximal spread of local anesthetics may cause possible quadriceps weakness. The distal spread of local anesthetics may increase analgesic effect via sciatic nerve. The different volumes for ACB is a topic of discussion. The aim of this study is to compare the different volumes of US-guided ACB performing for postoperative analgesia management after total knee arthroplasty surgery.
Randomized controlled single blind trial for the evaluation of the treatment of the surgical wound healing process with Platelet-Rich-Fibrin compared to the gold standard (without Platelet-Rich-Fibrin) in patients undergoing knee replacement.
To verify and assess the safety and efficacy of newly developed knee prosthesis (Wuhan Yijiabao Biomaterial Co., Ltd.) in total knee arthroplasty.