Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT05477940
Other study ID # 2021-R-1
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date September 1, 2022
Est. completion date September 1, 2024

Study information

Verified date July 2022
Source Shandong Branden Med.Device Co.,Ltd
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This trial is a prospective, two center single group registration pilot trial aiming to evaluate the product safety, and provide information for the later confirmatory test design according to the results.


Description:

This trial is a prospective, two center single group registration pilot trial with late lumen loss in stent (LLL), mace event and target lesion failure (TLF) as the main endpoint. Subjects were followed up clinically or by telephone at 1 month, 3 months, 6 months, 9 months and 12 months, and coronary angiography was performed at the target lesion segments for 6 months to calculate lumen loss. Analyze and evaluate the collected data, preliminarily evaluate the product safety, and provide information for the later confirmatory test design according to the results.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 30
Est. completion date September 1, 2024
Est. primary completion date September 1, 2023
Accepts healthy volunteers No
Gender All
Age group 18 Years to 75 Years
Eligibility Inclusion Criteria: - (1) General inclusion criteria - The patient must be 18-75 years old; ? The patient has evidence of ischemia (such as chest pain or functional examination such as stress test, which determines that he has stable or unstable angina pectoris or asymptomatic myocardial ischemia) and is suitable for elective PCI; - The patient must be a qualified candidate for PCI; ? Female patients of childbearing age had no pregnancy plan for up to one year after the starting operation. Women of childbearing age must have a pregnancy test and get negative results according to the regulations of the local test center 14 days before the starting operation. - Female patients were not breast-feeding during the screening visit and had no breast-feeding plan for up to 1 year after the starting operation; ? The patient agrees not to participate in other clinical trials until the end point of this trial is reached; ? The patient / legally authorized representative understands the purpose and procedure of the test and voluntarily signs the informed consent form; Exclusion Criteria: - ? Cardiogenic shock; - It is known that the left ventricular ejection fraction (LVEF) measured by quantitative analysis is less than 30%. For patients with stable coronary heart disease, LVEF measured within 6 months before operation is effective. For patients with acute coronary syndrome (ACS), LVEF must be measured before randomization to determine whether the patients meet the conditions; - The patient has a high risk of bleeding, or has a history of bleeding tendency and coagulation disorder; Major gastrointestinal bleeding within 6 months; Severe hematuria; There are contraindications to antiplatelet preparation and anticoagulant treatment, and antithrombotic treatment cannot be carried out; - Patients have allergic / hypersensitive reactions to aspirin, clopidogrel, heparin and ticlopidine hydrochloride (platelet inhibitor); - Patients have allergies or contraindications that inhibit the device materials and degradation products (rapamycin, polyglycolide and lactide) and cannot be completely cured before treatment. - The patient is allergic to contrast medium and cannot be completely cured before treatment. - Any surgical treatment requiring general anesthesia or interruption of aspirin or P2Y12 inhibitors is planned within 365 days after operation. - The patient received target vessel PCI within 365 days before operation. If the patient has received non target vessel PCI Treatment > 30 days before operation, the patient can still be enrolled in this trial. - Patients expected to require staged PCI of target vessels. - Acute myocardial infarction within one week; A series of clinical symptoms of the patient are consistent with new acute myocardial infarction (AMI). - During screening, the patient was determined to have arrhythmia according to any of the following criteria; Patient a needs coumarin or any other long-term oral anticoagulant; B patient may have hemodynamic instability due to arrhythmia; Patients with C had poor survival and prognosis due to arrhythmia; - The patient had severe peripheral vascular disease and could not be safely inserted with 6F sheath; - Stroke (CVA) or transient ischemic attack (TIA) occurred in the past 6 months; Intracranial hemorrhage, permanent neurological deficit, or any known intracranial lesions (such as aneurysms, arteriovenous malformations, etc.) have occurred in the past ? Major surgery within six weeks; ? Leukocyte count < 4.0 * 109cells / L and platelet count < 100 * 109cells / L; ? Severe renal and liver dysfunction; ? The life expectancy of patients is less than 12 months; ? The patient is receiving immunosuppressive therapy or is known to have immunosuppressive or autoimmune diseases (such as human immunodeficiency virus infection, systemic lupus erythematosus, etc.); Note: immunotherapy does not include hormone therapy; ? Patients who participate in clinical trials of other drugs or devices and fail to reach the main end point of the study; ? Patients who are unable or unwilling to participate in this trial, and the researchers believe that they are not suitable to participate in this trial. 8.2 angiographic exclusion criteria 1. The target lesion is located in the left main trunk and more than one lesion (not a single target lesion); 2. The% ds of visual or quantitative evaluation of target lesions is less than 50%, and the blood flow TIMI is less than grade 1. 3. The Dmax of target lesions measured by online QCA exceeds the range of 2.5mm-3.53.5mm, or the RVD measured by visual inspection exceeds the range of 2.5mm-3.53.5mm. 4. The visual length of target lesion or the length measured by online QCA is not within the range of = 28 = 28mm. 5. The target lesion of the right coronary artery (RCA) at the aortic opening (within 3mm of the aortic junction of RCA); 6. The target lesion is located within 3mm from the starting point of left anterior descending artery (LAD) or left circumflex artery (LCX). 7. The target lesion involves bifurcation and has the following characteristics: A side branch diameter = 2mm; B diameter stenosis = 50%; The C lateral branch needs to use protective guide wire or the lateral branch needs to be pre expanded. 8. Anatomical structures near or within the target lesion hinder the delivery of zinc alloy stents, including: A extreme reverse arch (= 90 °) at the proximal end of the target lesion or within the lesion; B. excessive bending of the proximal end of the target lesion or within the lesion (= two 45 ° angles); C moderate or severe calcification near or inside the target lesion. 9. The target lesion or target vessel involves myocardial bridge; 10. Angiographic images showed that the target vessel contained thrombus; 11. Before the starting operation, the target vessel has been treated with stent, and the zinc alloy stent will need to pass through the stent to reach the target lesion; 12. The target vessel has been treated with stent, and the target lesion is located within 5mm of the proximal end of the treated lesion; 13. The pre dilated balloon could not expand completely at the target lesion. Full expansion is based on the following criteria: A. the stenosis rate (% DS) of participating lesion diameter must be < 40% (visual inspection); B blood flow reaches timi3 (visual inspection); C no angiographic complications (e.g. distal embolization, collateral occlusion); D no interlayer, NHLBI grade, d-f type; E no persistent chest pain (> 5 minutes) and no ST segment depression or elevation lasting > 5 minutes.

Study Design


Intervention

Device:
Absorbable zinc alloy drug eluting coronary stent system
Absorbable zinc alloy drug eluting coronary stent system" (hereinafter referred to as "stent system") consists of "delivery system" and "drug stent (hereinafter referred to as stent)" pressed on the balloon end of the delivery system

Locations

Country Name City State
n/a

Sponsors (2)

Lead Sponsor Collaborator
Shandong Branden Med.Device Co.,Ltd Shandong Rientech Medical Tech Co., Ltd.

Outcome

Type Measure Description Time frame Safety issue
Primary late lumen loss Difference between the minimum lumen diameter immediately after operation and the minimum lumen diameter 6 months after operation 6 months after operation
Primary incidence of target lumen failure(TLF) proportion of the number of patients with cardiac death, target vessel myocardial infarction, or clinical symptom driven target vessel revascularization in the total number 6 months after operation
Primary incidence of major adverse cardiac events(MACE) proportion of the number of patients with cardiac death, myocardial infarction or target lesion revascularization (TLR) in the total number 6 months after operation
Primary incidence of target lumen failure(TLF) proportion of the number of patients with cardiac death, target vessel myocardial infarction, or clinical symptom driven target vessel revascularization in the total number 1 months after operation
Primary incidence of major adverse cardiac events(MACE) proportion of the number of patients with cardiac death, myocardial infarction or target lesion revascularization (TLR) in the total number 1 months after operation
Secondary Device success rate It means that the instrument can be successfully delivered to the target lesion as expected, the stent can be expanded normally, and the catheter can be successfully withdrawn to the outside of the body. in the operation
Secondary Operation Success Rate After stent implantation, stent diameter stenosis < 30% (visual), TIMI flow class 3, and hospitalization MACE events did not happen 0 to 24 hours after intervention
Secondary Thrombotic events incidence According to ARC definition it includes deterministic thrombosis, possible thrombosis and not eliminating thrombosis; point-in-time include acute within 24h, subacute between 2 and 30 d and later period over 30 d 1, 3, 6, 9 and 12 months after operation
Secondary incidence of target lumen failure(TLF) proportion of the number of patients with cardiac death, target vessel myocardial infarction, or clinical symptom driven target vessel revascularization in the total number 3, 9,12 months after operation
Secondary incidence of major adverse cardiac events(MACE) proportion of the number of patients with cardiac death, myocardial infarction or target lesion revascularization (TLR) in the total number 3, 9,12 months after operation
See also
  Status Clinical Trial Phase
Recruiting NCT05196659 - Collaborative Quality Improvement (C-QIP) Study N/A
Completed NCT05088291 - Application of a New X-ray Protective Device in Coronary Interventional Therapy
Completed NCT03076801 - Does Choral Singing Help imprOve Stress in Patients With Ischemic HeaRt Disease? N/A
Completed NCT04584645 - A Digital Flu Intervention for People With Cardiovascular Conditions N/A
Not yet recruiting NCT04995159 - Optimized Antiplatelet Therapy in Patients With CHD After Implantation of NeoVas™ BRS System N/A
Recruiting NCT02967718 - Innovation Research of Differentiation and Treatment Methods Based on CHD Phlegm and Blood Stasis Syndrome N/A
Completed NCT02888652 - Study on the Registration of Coronary Heart Disease Patients Undergoing PCI
Completed NCT02163044 - The Hellenic Postprandial Lipemia Study (HPLS)
Terminated NCT02045134 - Supplementation With Polyphenol-Rich Foods and Atrial Fibrillation After a Cardiac Surgery N/A
Active, not recruiting NCT02244853 - Heart Rate and Cardiovascular Diseases Prognosis in People With Stable Coronary Artery Disease N/A
Completed NCT02440893 - Understanding the Effect of Metformin on Corus CAD (or ASGES)
Completed NCT01826552 - Comparison of the Angiographic Result of the Orsiro Hybrid Stent With Resolute Integrity Stent Phase 4
Completed NCT01920009 - Impact of Motivational Interviews Within Pharmacy Care Upon Adherence to Cardiovascular Medicines N/A
Completed NCT02753829 - Home-based Cardiovascular Rehabilitation, Maintenance Phase, in Subjects With Coronary Artery Disease N/A
Terminated NCT01906957 - Cognition and Exercise Training N/A
Recruiting NCT01689688 - Healing Response to Everolimus-eluting Stent Implantation; Serial Assessment With opticaL Coherence Tomography N/A
Completed NCT01779401 - Clopidogrel Response Evaluation and AnTi-Platelet InterVEntion in High Thrombotic Risk PCI Patients N/A
Recruiting NCT01456364 - Intracoronary Stenting and Antithrombotic Regimen: ADjusting Antiplatelet Treatment in PatienTs Based on Platelet Function Testing Phase 4
Recruiting NCT01462799 - COR-PRIM: Problem-based Learning (PBL) After Coronary Heart Disease (CHD) - Long-term Evaluation in Primary Care of Self-care N/A
Completed NCT01486030 - Effect of Exercise Stress Testing on Peripheral Gene Expression Using Corus CAD (or ASGES) Diagnostic Test