Coronary Artery Disease Clinical Trial
— xSPECT MPIOfficial title:
xSPECT-based Myocardial Perfusion Scintigraphy: Consistency of Functional Values and Feasibility of Myocardial Uptake Quantitation in Patients With Suspected Coronary Artery Disease (xSPECT MPI Study)
This study is to evaluate the feasibility of myocardial Standardized Uptake Volume (SUV) assessment by means of X- (Single photon emission tomography) SPECT/Computed tomography (CT), to assess normal reference value under rest and stress in a homogeneous population without Coronary Artery Disease (CAD) and to assess the variation of absolute quantitative SUV measurements under rest and stress. The values will be evaluated in comparison with perfusion Positron Emission Tomography (PET)/CT (using 82Rb as perfusion tracer) and CT coronary angiography (CTCA) with contrast medium.).
| Status | Recruiting |
| Enrollment | 50 |
| Est. completion date | February 2024 |
| Est. primary completion date | February 2024 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 18 Years and older |
| Eligibility | Inclusion Criteria: - Referral to non-invasive nuclear ischemia test as part of clinical care - Suspected coronary artery disease based on clinical symptoms - Informed Consent as documented by signature Exclusion Criteria: - Pregnancy - Allergy against adenosine - Allergy against iodinated contrast medium - Recent myocardial infarction (<1 month) - Previous history of coronary revascularization - Severe asthma - Thyroid hyperfunction - atrioventricular block (AV) Block > I grade - Arrhythmic cardiopathy - Weight >101 Kg. - Acute or chronic renal impairment defined as Serum-Creatinine: above 1.5x upper limit of normal (ULN) and/or glomerular filtration rate (GFR) < 30 ml/min - Inability to follow the procedures of the study, e.g. due to language problems, psychological disorders, dementia, etc. of the participant, - Participation in another study with investigational drug within the 30 days preceding and during the present study, - Enrolment of the investigator, his/her family members, employees and other dependent persons, - Claustrophobia - Intake of caffeine <24 Hours before the first day of examination - Enrolment into another study using ionizing radiation within the previous 12 months. |
| Country | Name | City | State |
|---|---|---|---|
| Switzerland | Clinic of Radiology & Nuclear Medicine, University Hospital of Basel | Basel |
| Lead Sponsor | Collaborator |
|---|---|
| University Hospital, Basel, Switzerland | Siemens Corporation, Corporate Technology |
Switzerland,
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | Absolute flow quantification (assessed by PET/CT) | Consistency of quantitative parameters assessed by xSPECT compared to the "gold standard" which includes absolute flow quantification (assessed by PET/CT). The feasibility of myocardial SUV assessment by means of X-SPECT/CT will be tested by correlating the automatically calculated values with automatically calculated, PET-derived absolute blood flows. Rationale: values of quantified myocardial uptake are expected to be reliable the more they correlate with absolutely quantified myocardial blood flow in the myocardium, given the expected proportionality between uptake and subtending coronary blood flow. | 60 minutes at Day 1 | |
| Primary | presence of significant coronary stenoses (CTCA) | Consistency of quantitative parameters assessed by xSPECT compared to the "gold standard" which includes the presence of significant coronary stenoses (CTCA). Normal reference values under rest and stress in a homogeneous population without CAD will be evaluated in comparison with perfusion 82Rb-PET/CT and CT coronary angiography (CTCA) with contrast medium. Rationale: a coronary artery disease can be ruled out in patients with normal 82Rb-PET and without detectable stenoses on CTCA, thus identifying a subpopulation of normal patients, wherein reference normal values can be provided. | 120 minutes at Day 2 | |
| Secondary | Determination of uptake patterns that are suggestive for CAD | Values of quantified myocardial uptake (SUV) will be identified and correlated to pathological perfusion patterns as determined by 82Rb-PET/CT.
Rationale: it is expected that patients with pathological PET imaging and reduced flow rates also present with reduced myocardial uptake of 99mTc-sestamibi. |
one point assessment after interventions at day 2 | |
| Secondary | Quantitative 99mTC-sestamibi uptake values of the whole myocardium | Quantitative 99mTC-sestamibi uptake values of the whole myocardium, analysis of the diagnostic accuracy. Values will be correlated to image-driven diagnosis of CAD Rationale: it is foreseen that a diagnosis can be provided by finding reduced myocardial uptake of 99mTc-sestamibi | one point assessment after interventions at day 2 | |
| Secondary | Comparison of PET/CT, standard Myocardial perfusion SPECT (MPS) and new quantitative 99mTc-sestamibi xSPECT/quantitative computerized tomography (QCT) in the same patient | Comparison of sensitivity, specificity and accuracy of PET/CT, standard MPS and new quantitative 99mTc-sestamibi xSPECT/QCT in the same patient. Using the final clinical diagnosis of CAD, the diagnostic accuracy of each methodology will be tested by means of receiver operating characteristic (ROC) curves.
Rationale: it is expected that a quantitative approach can increase the diagnostic accuracy of SPECT by enhancing its sensitivity in case of globally reduced myocardial perfusion, similarly to what gained by quantitative PET |
one point assessment after interventions at day 2 | |
| Secondary | Interobserver variability of all imaging modalities | Interobserver variability of all imaging modalities. A kappa- correlation coefficient will be calculated for all three modalities.
Rationale: the quantitative data should provide higher interobserver consistency in the evaluation of patients with suspected CAD with SPECT, thus allowing for similar variability compared to quantitative PET. |
one point assessment after interventions at day 2 | |
| Secondary | Interobserver variability of qualitative and quantitative assessments | Interobserver variability of qualitative and quantitative assessments: a kappa correlation coefficient will be evaluated.
Rationale: the quantitative data should provide higher interobserver consistency in the evaluation of patients with suspected CAD |
one point assessment after interventions at day 2 |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |