Clinical Trial Summary

The objective of this study is to assess the safety and efficacy of the Orsiro Sirolimus Eluting Coronary Stent System in the treatment of subjects with up to three native de novo or restenotic (standard PTCA only) coronary artery lesions compared to the Xience coronary stent system.


Description:

The BIOTRONIK BIOFLOW-V clinical trial is a prospective, multicenter, randomized, controlled trial combining data on the randomized subjects with data from two historical studies by employing a Bayesian approach. Subjects with CAD that qualify for PCI with stenting will be screened per the protocol inclusion and exclusion criteria to achieve a total of up to 1,400 randomized subjects. Eligible subjects will be randomized in a 2:1 ratio, stratified by study center, to undergo percutaneous coronary revascularization with either the Orsiro Sirolimus Eluting Stent System (treatment group) or the Xience Everolimus Eluting Stent System (control group). Subjects may receive treatment of up to three target lesions, one or two target lesions per target vessel, for a maximum of two target vessels. The target lesion(s) must be de novo or restenotic lesion(s) of ≤ 36 mm in length in native coronary artery(ies), with a reference vessel diameter of 2.25-4.0 mm. Treatment of restenotic lesions is allowed provided that the target lesion was previously treated with PTCA only. All treatment with study stents is to be performed during a single index procedure. Note: Concurrent treatment of non-target lesions during the index procedure is not allowed. Randomized subjects will have clinical follow-up at 1 month, 6 months, 12 months and at 2, 3, 4 and 5 years following the index procedure. To assess the non-inferiority of the Orsiro stent compared to the Xience stent, BIOFLOW-V randomized subjects will be combined with historical subjects from the BIOFLOW-II and BIOFLOW-IV randomized trials employing a Bayesian approach. Only subjects who meet all clinical and angiographic eligibility criteria of the BIOFLOW-V trial will be included in the analysis.


Recruitment information / eligibility

Status Completed
Enrollment 1334
Est. completion date March 2021
Est. primary completion date April 2017
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. Subject is =18 years or the minimum age required for legal adult consent in the country of enrollment. 2. Subject is an acceptable candidate for PCI. 3. Subject is an acceptable candidate for CABG. 4. Subject has clinical evidence of ischemic heart disease, stable or unstable angina pectoris or documented silent ischemia. 5. Subject is eligible for dual anti-platelet therapy treatment with aspirin plus either, clopidogrel, prasugrel, ticagrelor or ticlopidine. 6. Subject has provided written informed consent. 7. Subject is willing to comply with study follow-up requirements. Each target lesion/vessel must meet all of the following angiographic criteria for the subject to be eligible for the trial: 1. Subject has up to three target lesions in up to two separate target vessels (two target lesions in one vessel and one target lesion in a separate vessel). 2. Target lesion must be de novo or restenotic lesion in native coronary artery; restenotic lesion must have been treated with a standard PTCA only. 3. Target lesion must be in major coronary artery or branch (target vessel). 4. Target lesion must have angiographic evidence of = 50% and < 100% stenosis (by operator visual estimate). If the target lesion is < 70% stenosed, clinical evidence of ischemia by positive functional study, CT, electrocardiography, FFR, or post infarct angina. 5. TIMI flow > 1. 6. Target lesion must be = 36 mm in length by operator visual estimate. 7. Target vessel RVD of 2.25-4.0 mm by operator visual estimate. 8. Target lesion must be treatable with a maximum of two overlapping stents. Exclusion Criteria: 1. Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with acute ST elevation myocardial infarction (STEMI) within 72 hours prior to the index procedure. Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment. 2. Subject is hemodynamically unstable. 3. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study. 4. Subject has a known allergy to contrast medium that cannot be adequately pre-medicated, or any known allergy to thienopyridine, aspirin, both heparin and bivalirudin, L-605 cobalt-chromium (Co-Cr) alloy or one of its major elements (cobalt, chromium, tungsten and nickel), acrylic, fluoropolymers, silicon carbide, PLLA, sirolimus or everolimus. 5. Revascularization of any target vessel within 9 months prior to the index procedure or previous PCI of any non-target vessel within 30 days prior to the index procedure. 6. Planned treatment of a lesion not meeting angiographic inclusion and exclusion criteria during the index procedure or after the index procedure. 7. Planned surgery within 6 months of index procedure unless dual antiplatelet therapy can be maintained throughout the peri-surgical period. 8. History of a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure. 9. Subjects with active bleeding disorders, active coagulopathy, or any other reason, who are ineligible for DAPT. 10. Subject will refuse blood transfusions. 11. Subject has documented left ventricular ejection fraction (LVEF) < 30% within 90 days prior to the index procedure. 12. Subject is dialysis-dependent. 13. Subject has impaired renal function (i.e., blood creatinine > 2.5 mg/dL or 221 µmol/L determined within 7 days prior to the index procedure). 14. Subject has leukopenia (i.e. < 3,000 white blood cells/mm3), thrombocytopenia (i.e. < 100,000 platelets/mm3) or thrombocytosis (i.e. > 700,000 platelet/mm3). 15. Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted), or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted). 16. Subject is receiving chronic anticoagulation (e.g. coumadin, dabigatran, apixaban, rivaroxaban or any other agent). 17. Subject has life expectancy of < 1 year. 18. Subject is participating in another investigational (medical device or drug) clinical study. Subjects may be concurrently enrolled in a post-market study, as long as the post-market study device, drug or protocol does not interfere with the investigational treatment or protocol of this study. 19. In the investigator's opinion, subject will not be able to comply with the follow-up requirements. Subjects will be excluded from the trial if any of the target lesions/vessels meets any of the following angiographic criteria: 1. Target lesion is located within a saphenous vein graft or arterial graft. 2. Target lesion is a restenotic lesion that was previously treated with a bare metal or drug eluting stent (in-stent restenosis). 3. Target lesion has any of the following characteristics: 1. Lesion location is within the left main coronary artery, or within 3 mm of the origin of the left anterior descending (LAD) or left circumflex (LCX). 2. Involves a side branch of > 2.0 mm in diameter. Note: Lesions within 3 mm of the origin of the right coronary artery may be treated. 4. Target vessel/lesion is excessively tortuous/angulated or is severely calcified, that would prevent complete inflation of an angioplasty balloon. This assessment should be based on visual estimation. 5. Target vessel has angiographic evidence of thrombus. 6. Target lesion is totally occluded (100% stenosis). 7. Target vessel was treated with brachytherapy any time prior to the index procedure.

Study Design


Intervention

Device:
Orsiro DES
Orsiro is a device/drug combination product composed of two components, a device (coronary stent system including a cobalt chromium stent platform), and a drug product (a formulation of sirolimus) contained in a bioabsorbable polymer coating.
Xience DES


Locations

Country Name City State
n/a

Sponsors (4)

Lead Sponsor Collaborator
Biotronik, Inc. Baim Institute for Clinical Research, Biotronik AG, Medstar Health Research Institute

Countries where clinical trial is conducted

United States,  Australia,  Belgium,  Canada,  Denmark,  Germany,  Hungary,  Israel,  Korea, Republic of,  Netherlands,  New Zealand,  Spain,  Switzerland, 

References & Publications (4)

Doros G, Massaro JM, Kandzari DE, Waksman R, Koolen JJ, Cutlip DE, Mauri L. Rationale of a novel study design for the BIOFLOW V study, a prospective, randomized multicenter study to assess the safety and efficacy of the Orsiro sirolimus-eluting coronary stent system using a Bayesian approach. Am Heart J. 2017 Nov;193:35-45. doi: 10.1016/j.ahj.2017.08.001. Epub 2017 Aug 5. — View Citation

Kandzari DE, Koolen JJ, Doros G, Massaro JJ, Garcia-Garcia HM, Bennett J, Roguin A, Gharib EG, Cutlip DE, Waksman R; BIOFLOW V Investigators. Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents. J — View Citation

Kandzari DE, Mauri L, Koolen JJ, Massaro JM, Doros G, Garcia-Garcia HM, Bennett J, Roguin A, Gharib EG, Cutlip DE, Waksman R; BIOFLOW V Investigators. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-elutin — View Citation

Roguin A, Kandzari DE, Marcusohn E, Koolen JJ, Doros G, Massaro JM, Garcia-Garcia HM, Bennett J, Gharib EG, Cutlip DE, Waksman R. Subgroup Analysis Comparing Ultrathin, Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin, Durable Polymer Everolimus — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Percentage of Participants With Target Lesion Failure (TLF) at 12 Months Post-Index Procedure by Bayesian Estimation TLF is defined as all cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven target lesion revascularization (TLR). 12-Months
Secondary Number of Lesions With Device Success Defined as attainment of < 30% residual stenosis of the target lesion using the assigned study stent only. Hospital Discharge (6-24 hours post-index procedure)
Secondary Number of Lesions With Lesion Success Defined as attainment of < 30% residual stenosis of the target lesion using any percutaneous method. Hospital Discharge (6-24 hours post-index procedure)
Secondary Number of Participants With Procedure Success Defined as attainment of < 30% residual stenosis of the target lesion using the assigned study stent only without occurrence of in-hospital major adverse cardiac events (MACE; composite of all-cause death, Q-wave or non-Q-wave MI, and any clinically-driven TLR). Hospital Discharge (6-24 hours post-index procedure)
Secondary Number of Participants With Myocardial Infarction Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Secondary Number of Participants With Myocardial Infarction or Cardiac Death Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Secondary Number of Participants With MACE and Individual MACE Components MACE events are defined as all-cause death, Q-wave or non-Q-wave MI, or any clinically-driven TLR. The number of participants with any MACE event is provided, as well as number of participants with each of the individual components. Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Secondary Number of Participants With TLF and Individual TLF Components TLF events are defined as cardiac death, target vessel Q-wave or non-Q-wave MI, or any clinically-driven TLR. The number of participants with any TLF event is provided, as well as number of participants with each of the individual components. Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Secondary Number of Participants With Target Vessel Failure (TVF) and Individual TVF Components TVF events are defined as cardiac death, target vessel Q-wave or non-Q-wave MI, or any clinically-driven TVR. The number of participants with any TVF event is provided, as well as number of participants with each of the individual components. Hospital Discharge (6-24 hours post-index procedure), 1, 6, 12 months, 2, 3, 4 and 5 years
Secondary Number of Participants With Stent Thrombosis Stent thrombosis according to the Academic Research Consortium criteria. 24 hours, 30 days, 1 year, and 5 years post-index procedure
See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A