Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01518777
Other study ID # Pro00006818
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date January 2012
Est. completion date December 16, 2016

Study information

Verified date September 2019
Source The Methodist Hospital System
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This is a pilot study to see whether cardiac imaging can be performed using half the standard dose of radioisotope.


Description:

The aim of this study is to compare the image quality of the half radioisotope dose scans obtained using a CZT (cadmium zinc telluride) camera with scans acquired using a standard of care imaging protocol/radioisotope dose performed on a traditional (conventional) camera.

The proposed strategy of a half dose/extended time protocol with the CZT camera should yield a similar count activity and consequently image quality equivalent to that detected by a conventional SPECT system.


Recruitment information / eligibility

Status Completed
Enrollment 74
Est. completion date December 16, 2016
Est. primary completion date December 16, 2016
Accepts healthy volunteers No
Gender All
Age group 18 Years to 90 Years
Eligibility Inclusion Criteria:

- = 18 years of age and referred for a clinically-indicated stress SPECT MPI study

- suspected or known coronary artery disease

- written informed consent

Exclusion Criteria:

- Evidence of a normal baseline scan after at least 50% of the protocol acquired baseline scans have been interpreted as being normal

- Participation in another investigational study within the preceding month

- Pregnant and/or breast-feeding female

- ECG evidence of left bundle branch block or paced rhythm

- Evidence of non-ischemic cardiomyopathy

- Presence of hypertrophic cardiomyopathy and/or severe valvular heart disease

- Severe claustrophobia or inability to lie flat for 20 minutes (the anticipated amount of time to complete the procedure)

- Known allergy to technetium-99m

- Potential contraindications to regadenoson use, due to severe lung disease; severe bradycardia (heart rate < 40 beats/min); second- or third degree atrioventricular heart block; sick sinus syndrome; long QT syndrome; severe hypotension; or decompensated heart failure.

Study Design


Intervention

Other:
Half-dose isotope for NuclearStressTest
Half-dose of tracer or radioisotope will be used for Nuclear stress test of the heart. This is imaging test of the heart to see the function of arteries of the heart.

Locations

Country Name City State
United States Houston Methodist Hospital Houston Texas

Sponsors (2)

Lead Sponsor Collaborator
S.M.Chang, MD The Methodist Hospital System

Country where clinical trial is conducted

United States, 

References & Publications (16)

Buechel RR, Herzog BA, Husmann L, Burger IA, Pazhenkottil AP, Treyer V, Valenta I, von Schulthess P, Nkoulou R, Wyss CA, Kaufmann PA. Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. Eur J Nucl Med Mol Imaging. 2010 Apr;37(4):773-8. doi: 10.1007/s00259-009-1375-7. Epub 2010 Jan 27. Erratum in: Eur J Nucl Med Mol Imaging. 2011 Jun;38(6):1172. — View Citation

Duvall WL, Croft LB, Ginsberg ES, Einstein AJ, Guma KA, George T, Henzlova MJ. Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera. J Nucl Cardiol. 2011 Oct;18(5):847-57. doi: 10.1007/s12350-011-9379-7. Epub 2011 Apr 29. — View Citation

Duvall WL, Sweeny JM, Croft LB, Barghash MH, Kulkarni NK, Guma KA, Henzlova MJ. Comparison of high efficiency CZT SPECT MPI to coronary angiography. J Nucl Cardiol. 2011 Aug;18(4):595-604. doi: 10.1007/s12350-011-9382-z. Epub 2011 Jun 3. — View Citation

Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA. 2007 Jul 18;298(3):317-23. — View Citation

Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ. Radiation dose to patients from cardiac diagnostic imaging. Circulation. 2007 Sep 11;116(11):1290-305. Review. — View Citation

Esteves FP, Raggi P, Folks RD, Keidar Z, Askew JW, Rispler S, O'Connor MK, Verdes L, Garcia EV. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009 Nov-Dec;16(6):927-34. doi: 10.1007/s12350-009-9137-2. Epub 2009 Aug 18. — View Citation

Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, Shah ND, Nasir K, Einstein AJ, Nallamothu BK. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med. 2009 Aug 27;361(9):849-57. doi: 10.1056/NEJMoa0901249. — View Citation

Fazel R, Shaw LJ. Radiation exposure from radionuclide myocardial perfusion imaging: concerns and solutions. J Nucl Cardiol. 2011 Aug;18(4):562-5. doi: 10.1007/s12350-011-9403-y. Review. — View Citation

Gimelli A, Bottai M, Giorgetti A, Genovesi D, Kusch A, Ripoli A, Marzullo P. Comparison between ultrafast and standard single-photon emission CT in patients with coronary artery disease: a pilot study. Circ Cardiovasc Imaging. 2011 Jan;4(1):51-8. doi: 10.1161/CIRCIMAGING.110.957399. Epub 2010 Nov 10. — View Citation

Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS; Quality Assurance Committee of the American Society of Nuclear Cardiology. Stress protocols and tracers. J Nucl Cardiol. 2006 Nov;13(6):e80-90. — View Citation

Herzog BA, Buechel RR, Katz R, Brueckner M, Husmann L, Burger IA, Pazhenkottil AP, Valenta I, Gaemperli O, Treyer V, Kaufmann PA. Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J Nucl Med. 2010 Jan;51(1):46-51. doi: 10.2967/jnumed.109.065532. Epub 2009 Dec 15. — View Citation

ICRP. Radiation dose to patients from radiopharmaceuticals. Addendum 3 to ICRP Publication 53. ICRP Publication 106. Approved by the Commission in October 2007. Ann ICRP. 2008;38(1-2):1-197. doi: 10.1016/j.icrp.2008.08.003. — View Citation

Mahmarian JJ, Shaw LJ, Olszewski GH, Pounds BK, Frias ME, Pratt CM; INSPIRE Investigators. Adenosine sestamibi SPECT post-infarction evaluation (INSPIRE) trial: A randomized, prospective multicenter trial evaluating the role of adenosine Tc-99m sestamibi SPECT for assessing risk and therapeutic outcomes in survivors of acute myocardial infarction. J Nucl Cardiol. 2004 Jul-Aug;11(4):458-69. — View Citation

Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53). Ann ICRP. 1998;28(3):1-126. — View Citation

Shaw LJ, Iskandrian AE. Prognostic value of gated myocardial perfusion SPECT. J Nucl Cardiol. 2004 Mar-Apr;11(2):171-85. Review. — View Citation

The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007;37(2-4):1-332. — View Citation

* Note: There are 16 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Image quality of the half-dose CZT versus full dose scans 1 Week
Secondary Total radiation dose/exposure of the half-dose CZT vs. full dose scans 1 Week
Secondary Total myocardial count activity and count rates obtained during each scan 1 Week
Secondary Agreement between the half-dose CZT vs. full dose scans on the presence and extent of fixed or reversible defects on a per-patient and vessel basis 1 Week
Secondary Agreement between the half-dose vs. full dose scans on gated data such as EF, left ventricular (LV) end-diastolic volume, LV end-systolic volume 1 Week
See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A