Clinical Trials Logo

Clinical Trial Summary

Percutaneous recanalization of total coronary occlusions (TCO) was historically hampered by high rates of restenosis and reocclusion. In the PRISON II and III trial we showed landmark reduction in restenosis with sirolimus-eluting stents (Cypher, Cordis Corporation) compared to conventional bare metal stents in TCO. In the PRISON III trial, we observed similar favourable results with second-generation zotarolimus-eluting stent (Resolute, Medtronic Inc.). Another drugs-eluting stent mounted with everolimus (Xience Prime, Abbott) also demonstrated favourable results in TCO. Recently, drug-eluting stents (DES) with bioresorbable polymer coatings were developed, to address safety concerns regarding the observation of very late stent thrombosis, due to hypersensitivity reactions, and chronic inflammation, on the durable polymer coating of DES. However, none of these DES with bioresorbable polymers were evaluated in patients with TCO. The PRISON IV trial is a prospective, randomized, single-blinded, multi-center trial, designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (ORSIRO, Biotronik Inc.) compared to everolimus-eluting stents with durable polymers (Xience Prime, Abbott) in patients with successfully recanalized TCOs.


Clinical Trial Description

A total of 330 patients are randomized to either hybrid sirolimus-eluting stent or everolimus-eluting stent after successful recanalization of TCO. Clinical follow-up at 1, 6, 12 months, 2, 3, 4, 5 year with angiographic follow-up at 9 months. In 60 patients a optical coherence tomography is performed during the 9 months follow-up angiography. Quantitative coronary and optical coherence tomography analysis is performed by two independent core laboratory. The primary end point is in-segment late luminal loss at 9 month angiographic follow-up. Secondary angiographic end points include the following; in-stent luminal loss, acute recoil, acute gain, net luminal gain, late loss index, minimal lumen diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9 months angiographic follow-up. Secondary clinical endpoints include a composite of major adverse cardiac events (death, MI and clinically driven target lesion revascularization); clinically driven target vessel revascularisation (TVR), target vessel failure (cardiac death, MI, clinically driven TVR) and stent thrombosis up to 5 year clinical follow-up. Tertiary optical coherence tomography end points at 9 months follow-up are the following: Percentage of uncovered stent struts, percentage of malapposed stent struts, tissue strut thickness, absolute and percentage of intimal hyperplasia. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01516723
Study type Interventional
Source R&D Cardiologie
Contact
Status Active, not recruiting
Phase Phase 3
Start date February 2012
Completion date May 2020

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A