Clinical Trials Logo

Clinical Trial Summary

There has been a shortage of nuclear isotopes, not only in Canada but around the world. New, more sensitive SPECT cameras can obtain better images in shorter scan times. These cameras have also shown the ability to use a smaller dose of radioisotope to obtain the images. New software has been tested on the standard camera, the GE Infinia-Hawkeye SPECT/CT. The Diagnostic Imaging Department of The University of Ottawa Heart Institute has also acquired a new camera, the Discovery NM530c CZT and has been doing heart scans in shorter times. The investigators will now be looking at the quality of images using less isotope during SPECT myocardial perfusion imaging for diagnostic and prognostic purposes.


Clinical Trial Description

SPECT MPI is well accepted as a reliable and cost-effective tool for diagnosis, risk stratification and management of patients with suspected or known coronary artery disease (CAD) (1;2). MPI represents approximately 40% of nuclear medicine patient studies and most of these use 99mTc-sestamibi or 99mTc-tetrofosmin(3). Rest/stress MPI using 99mTc-sestamibi and 99mTc-tetrofosmin uses more tracer doses than many other nuclear medicine tests and thus account for >50% of injected radiotracer activity(3). Thus, interruptions in the supply of 99Mo, the parent isotope of 99mTc, significantly affect stress MPI imaging and associated patient care.

Alternatives to 99mTc-sestamibi and 99mTc-tetrofosmin for perfusion imaging include 201Tl for SPECT imaging and 82Rb or 13NH3 for positron emission tomography (PET) imaging (4;5). MPI using 201Tl has similar diagnostic accuracy but image interpretation is more difficult due to greater scatter and attenuation. Moreover, the patient effective radiation dose for MPI using a standard injected dose of 3.5mCi of 201Tl is ~20 mSv. This radiation dose is twice that of 99mTc tracers which typically deliver an effective dose of ~10 mSv. PET imaging with 82Rb or 13NH3 is another alternative, but is much more expensive and not routinely available in Canada due to a very limited install base of PET scanners and associated cyclotrons. The number of SPECT cameras operational in Canada is more than 40 times the number of PET scanners. ;


Study Design

Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Related Conditions & MeSH terms


NCT number NCT01412827
Study type Interventional
Source Ottawa Heart Institute Research Corporation
Contact
Status Completed
Phase N/A
Start date April 2010
Completion date September 2014

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A