Coronary Artery Disease Clinical Trial
Official title:
Evaluation of Endothelial Progenitor Cell (EPC) Capturing (GENOUS) Stent After Coronary Stenting Utilizing Optical Coherence Tomography (OCT): the EGO Study
All patients who have received GENOUS stent implantation at Queen Mary Hospital for
treatment of ischemic heart disease are eligible for this study. Those with clinical
indications to undergo restudy coronary angiogram or staged procedure PCI will be primarily
recruited into this study.
Optical coherence tomography (OCT) will be performed early after stent implantation to
evaluate vascular healing response and neointimal coverage.
The GENOUS Stent is a bio-engineered 316L stainless steel coronary stent with a
biocompatible circumferential coating of anti-CD34 antibody, and will bind to and therefore
capture the circulatory endothelial progenitor cells (EPC) which have CD34 antigen on the
surface. Immobilization of EPCs on the stent surface will encourage differentiation and
proliferation of the EPCs into endothelial and neointimal layer. This stent has been used
extensively in 180 patients at Queen Mary Hospital with critical coronary stenosis.
Animal model has demonstrated that a functional endothelial layer could be formed as soon as
24 to 48 hours after GENOUS stent implantation (1). The HEALING-FIM registry has shown that
GENOUS stent is clinically safe and effective in the treatment of coronary stenosis (2).
Recent reports have further confirmed its efficacy in patients with acute coronary syndrome
requiring urgent revascularization (3,4).
Intracoronary frequency domain optical coherence tomography (FD-OCT) is a simple
catheter-based imaging technique using optic fibre to achieve very detailed assessment
(resolution down to 10 microns) of the stents, in terms of stent apposition, early
neointimal coverage (enhanced endothelialization) and late stent neointimal growth
(restenosis). It is performed as part of the routine cardiac catheterization procedure and
provides high-resolution cross sectional images of the coronary arteries. OCT has been shown
to be safe in clinical practice (5). The LightLab C7XR OCT System (Frequency Domain OCT) is
a commercially available product with CE Mark and FDA approval, and is being used in our EGO
Study. The Dragonfly OCT catheter used is a non-occlusive optic fibre which is extremely
small and flexible, and will pose absolutely no additional risk to the patient under
treatment, other than those inherent risks of a standard angioplasty procedure.
Despite data in animal model showed a fast and complete endothelization, there is no study
to verify and investigate on such healing benefits in human patients. Therefore, if
endothelization and early neointimal healing benefits of the GENOUS stent can be evaluated
by a reliable imaging technique, further studies can be carried out to extend the benefits
of the EPC capturing capacity.
;
Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |