Clinical Trials Logo

Clinical Trial Details — Status: Active, not recruiting

Administrative data

NCT number NCT01060657
Other study ID # wgs1996
Secondary ID
Status Active, not recruiting
Phase N/A
First received January 31, 2010
Last updated February 1, 2010
Start date December 2009
Est. completion date December 2011

Study information

Verified date January 2010
Source General Hospital of Chinese Armed Police Forces
Contact n/a
Is FDA regulated No
Health authority China: Ministry of Health
Study type Observational

Clinical Trial Summary

To evaluate the clinical values of using dose reduction techniques in 64-row multi-slice CT coronary artery imaging.


Description:

Five hundred patients will be recruited over one and half years from our institution and other hospitals for suspected coronary artery disease. All patients will give informed consent and our Institutional Review Board approved the study. To obtain relatively consistent image noise, patients will be limited to body height and weight of 160 cm to 175 cm,and 55 kg to 75 kg, respectively. Patients with acute heart failure, severe arrhythmia and severe renal dysfunction will be excluded from the cardiac studies.

All patients underwent CT coronary artery scans using a 64-row multi-detector CT (MDCT) scanner (Light Speed VCT, GE Healthcare)in supine position. The five hundred patients were divided into conventional (C)and low dose (L) scan groups with 250 patients in each group. The patient distributions in terms of height, weight, body mass index (BMI)and heart rate were similar for the two groups with no statistically significant difference. Patients will be given bocker of about 25-50 mg orally when necessary one-hour before the cardiac scans to control heart rates and reduce their variations. Patient heart rates during CT scans were 43 to 81. A single scout scan shall be performed on every patient to cover the whole heart area, which is about 12cm. CT calcification scoring scan was performed for every patient before the CT angiography (CTA) according to the standard protocols at our institution. Timing bolus scans were performed before CTA to determine the scan start delay time: A total of 15 ml contrast agent was injected intravenously. Cine scans were used to monitor the contrast enhancement in the aorta. An ROI was placed on the ascending aorta and contrast enhancement curve as function of time was measured to determine the blood circulation time between vein of the elbow and aorta. This time was then used to determine the optimal scan delay time for CTA. The retrospective ECG-gated helical CTA scan will be then performed with predetermined scan delay time and with minimum scan range to just cover the whole heart. 70 ml contrast agent will be injected at 4.5 ml/s injection rate intravenously followed by 30ml of saline at the same injection rate.Standard scan technique shall be used for the CTA scans for the C group including: 120kV,640mA,0.35s rotation speed, 0.625 mm slice thickness, body bowtie, and 0.20-0.26 pitch selected automatically by the scanner based on the patient heart rates. For patients in L group combinations of dose reduction techniques will be applied including the use of application-specific cardiac bowtie,and adaptive post-processing filter C2,and ECG mA modulation with full tube current of 450mA for cardiac phases of 40-80%and 90mA for the rest of the cardiac phases. Cardiac bowtie provides more x-rays near the center and less x-rays towards the edge compared to a typical body bowtie to optimize x-ray distribution for cardiac applications. Our previous studies have demonstrated its advantages of image noise reduction for the heart as well as overall dose (CTDI)reduction. The lower tube current selection for the patients in L group shall be based on previous studies which indicated that the noise reduction advantage of the adaptive post-processing filter C2 might be converted into the use of lower mA to achieve similar image noise as with higher mA in clinical applications.

All images will be reconstructed with standard segment reconstruction algorithm. For the L group with lower tube current, we will apply the adaptive post-processing filter C2 to reduce image noise. Two experienced radiologists quantitatively evaluated the image quality blindly in terms of the number of coronary arteries and smaller branches identified, the sharpness of vessel edges and contrast agent clarity in the vessels using scores of 1-4 with 4 being the highest. Score 4 would indicate that at least 13 coronary artery segments could be identified,and up to the 3rd branch. Also, all identified vessels have sharp edge and clear delineations of contrast agent in the vessels. If any one of the above parameters is not satisfactory, then the quality score would be 3 and 2 if any two parameters are not as good. Image noises will be measured for the two sets with ROI placed at the center of the ascending aorta in the same place for both groups. CTDI values will be recorded for each group and converted into effective dose (ED) using European DLP method. We shall perform statistical analyses on the quality scores,the noise measurements and the effective dose measurements from the two sets using t-test with the spss10.0 software.


Recruitment information / eligibility

Status Active, not recruiting
Enrollment 500
Est. completion date December 2011
Est. primary completion date May 2011
Accepts healthy volunteers Accepts Healthy Volunteers
Gender Both
Age group 30 Years to 70 Years
Eligibility Inclusion Criteria:

- body height and weight of 160 cm to 175 cm, and 55 kg to 75 kg, respectively.

Exclusion Criteria:

- with acute heart failure, severe arrhythmia and severe renal dysfunction.

Study Design

Observational Model: Case Control, Time Perspective: Prospective


Locations

Country Name City State
China NO.69 Road yongding Beijing haidian

Sponsors (3)

Lead Sponsor Collaborator
General Hospital of Chinese Armed Police Forces 181 Central Hospital of the Chinese PLA, Ningxia Medical University

Country where clinical trial is conducted

China, 

References & Publications (1)

Bischoff B, Hein F, Meyer T, Hadamitzky M, Martinoff S, Schömig A, Hausleiter J. Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I study. JACC Cardiovasc Imaging. 2009 Aug;2(8):940-6. doi: 10.1016/j.jcmg.2009.02.015. — View Citation

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A