Coronary Artery Disease Clinical Trial
To evaluate the clinical values of using dose reduction techniques in 64-row multi-slice CT coronary artery imaging.
Five hundred patients will be recruited over one and half years from our institution and
other hospitals for suspected coronary artery disease. All patients will give informed
consent and our Institutional Review Board approved the study. To obtain relatively
consistent image noise, patients will be limited to body height and weight of 160 cm to 175
cm,and 55 kg to 75 kg, respectively. Patients with acute heart failure, severe arrhythmia
and severe renal dysfunction will be excluded from the cardiac studies.
All patients underwent CT coronary artery scans using a 64-row multi-detector CT (MDCT)
scanner (Light Speed VCT, GE Healthcare)in supine position. The five hundred patients were
divided into conventional (C)and low dose (L) scan groups with 250 patients in each group.
The patient distributions in terms of height, weight, body mass index (BMI)and heart rate
were similar for the two groups with no statistically significant difference. Patients will
be given bocker of about 25-50 mg orally when necessary one-hour before the cardiac scans to
control heart rates and reduce their variations. Patient heart rates during CT scans were 43
to 81. A single scout scan shall be performed on every patient to cover the whole heart
area, which is about 12cm. CT calcification scoring scan was performed for every patient
before the CT angiography (CTA) according to the standard protocols at our institution.
Timing bolus scans were performed before CTA to determine the scan start delay time: A total
of 15 ml contrast agent was injected intravenously. Cine scans were used to monitor the
contrast enhancement in the aorta. An ROI was placed on the ascending aorta and contrast
enhancement curve as function of time was measured to determine the blood circulation time
between vein of the elbow and aorta. This time was then used to determine the optimal scan
delay time for CTA. The retrospective ECG-gated helical CTA scan will be then performed with
predetermined scan delay time and with minimum scan range to just cover the whole heart. 70
ml contrast agent will be injected at 4.5 ml/s injection rate intravenously followed by 30ml
of saline at the same injection rate.Standard scan technique shall be used for the CTA scans
for the C group including: 120kV,640mA,0.35s rotation speed, 0.625 mm slice thickness, body
bowtie, and 0.20-0.26 pitch selected automatically by the scanner based on the patient heart
rates. For patients in L group combinations of dose reduction techniques will be applied
including the use of application-specific cardiac bowtie,and adaptive post-processing filter
C2,and ECG mA modulation with full tube current of 450mA for cardiac phases of 40-80%and
90mA for the rest of the cardiac phases. Cardiac bowtie provides more x-rays near the center
and less x-rays towards the edge compared to a typical body bowtie to optimize x-ray
distribution for cardiac applications. Our previous studies have demonstrated its advantages
of image noise reduction for the heart as well as overall dose (CTDI)reduction. The lower
tube current selection for the patients in L group shall be based on previous studies which
indicated that the noise reduction advantage of the adaptive post-processing filter C2 might
be converted into the use of lower mA to achieve similar image noise as with higher mA in
clinical applications.
All images will be reconstructed with standard segment reconstruction algorithm. For the L
group with lower tube current, we will apply the adaptive post-processing filter C2 to
reduce image noise. Two experienced radiologists quantitatively evaluated the image quality
blindly in terms of the number of coronary arteries and smaller branches identified, the
sharpness of vessel edges and contrast agent clarity in the vessels using scores of 1-4 with
4 being the highest. Score 4 would indicate that at least 13 coronary artery segments could
be identified,and up to the 3rd branch. Also, all identified vessels have sharp edge and
clear delineations of contrast agent in the vessels. If any one of the above parameters is
not satisfactory, then the quality score would be 3 and 2 if any two parameters are not as
good. Image noises will be measured for the two sets with ROI placed at the center of the
ascending aorta in the same place for both groups. CTDI values will be recorded for each
group and converted into effective dose (ED) using European DLP method. We shall perform
statistical analyses on the quality scores,the noise measurements and the effective dose
measurements from the two sets using t-test with the spss10.0 software.
;
Observational Model: Case Control, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |