Coronary Artery Disease Clinical Trial
Official title:
In-Vivo Vascular Response of Sirolimus-,Paclitaxel- and Zotarolimus-Eluting Stents in Long Lesions Requiring Overlapping. A Prospective, Randomized, Controlled Study Using Optical Coherence Tomography
Increasing lesion complexity in percutaneous coronary interventions (PCI) has warranted the use of overlapping drug-eluting stents. Whether the substantial impairment of arterial healing observed at sites of overlap in preclinical pathologic studies persists in patients undergoing PCI is unknown. Consecutive patients with long lesions in native coronary vessels requiring stents in overlap are prospectively randomized to receive multiple sirolimus-,paclitaxel polymer-or zotarolimus eluting stents versus bare metal stents. The completeness of stent struts coverage and/or late malapposition are evaluated by Optical Coherence Tomography at 6 months follow-up
If overlapping drug-eluting stents provide increased vessel toxicity is not known. Given the
association of delayed healing and incomplete endothelialization observed in animal and
human autopsy studies at overlapping sites it is unclear why most patients do well with
multiple DES implanted. OCT detecs smaller degrees of in-stent neointima more accurately
than IVUS and might be a useful method for identify strut coverage and/or malapposition.
Patients if eligible on the basis of clinical and angiographic criteria, are randomized
(2:2:2:1) to receive multiple TAXUS Libertè™ vs Cypher Select™ vs Endeavor™ vs Libertè BM
stents, in overlap. Stent implantation are done accordingly to the normal interventional
practice. QCA and IVUS are performed at the end of optimal stents placement per visual
judgement (residual stenosis < 10%, TIMI 3 flow). Stent, lumen size and volume as well as
complete stent strut apposal will be determined by IVUS analysis. Clinical follow-up will
take place at 1 month (±1 week), 6 months (±2 weeks) and 1 year (±2 weeks). At 6-months
follow-up all patients will undergo a quantitative coronary angiography (QCA), IVUS and
Optical Coherence Tomography (LightLab OCT Imaging M2, automated pull back and flushing
combination)assessments.
OCT images will be acquired at 15-30 frames per second. Blind corelab quantitative strut by
strut analysis will be performed using a novel dedicated software at each 0.5 mm section.
The following OCT variables will be evaluated:number of visualized strut per section,
mean-max neointimal thickness per section, % struts well apposed with neointima at
overlapping vs non overlapping sites, % struts without neointima, % struts malapposed, rate
of > 30% uncovered struts/total number of struts per section.
;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |