Filter by:This clinical investigation is intended to demonstrate safety and effectiveness of the Volt™ Pulsed Field Ablation (PFA) Catheter Sensor Enabled™, the Volt™ PFA Generator, Agilis™ NxT Steerable Introducer Dual-Reach™, and EnSite™ X EP System EnSite™ Pulsed Field Ablation Module (for simplicity of reference this device collection will hereafter be referred to as the Volt™ PFA system) for the treatment of symptomatic, recurrent, drug-refractory paroxysmal and persistent atrial fibrillation.
This is a prospective safety and feasibility study to evaluate the safety of the FieldForce™ Ablation system in patients with ventricular arrhythmia divided into two groups: VT (VCAS-I) and frequent premature ventricular complex (VCAS-II).
This is a prospective, non-randomized, multi-center, real-world post-market study to collect and evaluate data regarding the performance of the enhanced atrial fibrillation detection algorithm of the Assert-IQTM Implantable Cardiac Monitor (ICM) device.
This study is a first-in-human, prospective, multi-center, pre-market single-arm clinical trial to evaluate the Future Cardia™ ICM.
Cardiology Research Dubrava registry is a prospective, single centre registry including patients with acute coronary syndrome with and without ST segment elevation, patients with heart failure who were prescribed with SGLT-2 inhibitors, patients implanted with TAVI, patients with venous thromboembolism, patients with pulmonary embolism who underwent thromboaspiration procedure, patients implanted with ICD, CRT and conduction system pacing devices, as well as patients with atrial fibrillation who underwent pulmonary vein isolation and are prescribed with long-term anticoagulation therapy.
The goal of this Observational Prospective Multi-center Study is to observe the acute and long-term safety and performance outcomes after spatiotemporal dispersion-based AF/AT ablation utilizing the Volta Medical AI software in "real-life" clinical practice, without any imposed clinical workflow. Moreover, this study will allow to collect medico-economic data related to the tailored ablation strategy guided by the Volta Medical AI software.
The goal of this interventional study is to evaluate the risk of atrial fibrillation (AF) and other cardiac arrhythmias and diseases in breast cancer patients treated with radiation therapy (RT). In addition to regular follow-up of patients by the radiation oncologist for 5 years, cardiovascular screening at the end of follow-up, combining the use of a connected watch and a cardiological check-up, could make it possible to identify precisely the types and frequencies of these sometimes asymptomatic, and probably underestimated, cardiac diseases. The main questions it aims to answer are: - To assess the incidence of AF and other cardiac arrhythmias and diseases occurring within 5 years after RT - To evaluate absorbed doses in the heart and cardiac substructures (chambers, conduction nodes, coronaries, pulmonary veins) based on auto-segmentation models developped with deep learning algorithms - To investigate whether the risk of AF and other cardiac arrhythmias and diseases is associated with cardiac irradiation characterized by these absorbed doses (dose-response relationship) Participants will be included between 2023 and 2025, 5 years after their RT: - Retrospective data collection will be based on a medical questionnaire designed to identify cardiac pathologies present prior to RT and those having occured in the past, between RT and 5 years post-RT. - Cross-sectional data collection will be based on screening for cardiac pathologies using a connected watch worn for 1 month (silent AF screening) and a cardiology consultation (including ECG and echocardiography) to identify cardiac pathologies at 5 years post-RT possibly not identified in the retrospective data collection.
This study will assess the feasibility of performing pre-hospital resuscitative endovascular balloon occlusion of the aorta (REBOA) as an adjunct to conventional Advanced Life Support (ALS) in patients suffering from non-traumatic out of hospital cardiac arrest (OHCA). As well as providing valuable insights into the technical feasibility of performing this procedure as part of a resuscitation attempt, the study will also document the beneficial physiological effects of REBOA in this group of patients.
1. Questionnaire for supraventricular tachycardia: About history and targeted diagnosis of supraventricular tachycardia 2. Extended Signal-averaged ECG for detailed P-Wave analysis and to calculate a virtual atrial electrocardiogram (ECG)
The purpose of the Long term Evaluation of Cardiac Arrhythmias after Transcatheter Aortic Valve Implantation (LOCATE) Registry is to perform long-term ambulatory monitoring of patients with severe aortic stenosis who undergo trans-catheter aortic valve implantation (TAVI) and develop new onset conduction system abnormalities post-procedure that do not require urgent permanent pacemaker (PPM) implantation. The primary objectives of this study are to assess the incidence of late onset heart block necessitating PPM implantation and to evaluate the incidence of new onset atrial fibrillation (AF) following TAVI. This study aims to provide valuable insights into the long-term cardiac health of TAVI patients and inform the development of improved treatment strategies for aortic stenosis patients with conduction system abnormalities.