Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01275144
Other study ID # 12596
Secondary ID H9P-EW-LNCG
Status Completed
Phase Phase 1
First received
Last updated
Start date December 2010
Est. completion date February 2011

Study information

Verified date November 2018
Source Eli Lilly and Company
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to determine how much lorazepam gets into the blood and how long it takes the body to get rid of it when given together with LY2216684. Information about any side effects that may occur will also be collected.


Recruitment information / eligibility

Status Completed
Enrollment 28
Est. completion date February 2011
Est. primary completion date February 2011
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years to 65 Years
Eligibility Inclusion Criteria:

- Are overtly healthy, as determined by medical history and physical examination.

- Male participants - Agree to use a reliable method of birth control during the study and for 1 month following the last dose of study drug.

- Female participants - Are women of child-bearing potential who test negative for pregnancy at the time of enrollment, have used a reliable method of birth control for 6 weeks prior to administration of study drug, and agree to use a reliable method of birth control during the study and for 1 month following the last dose of study drug; or Women not of child-bearing potential due to surgical sterilization (hysterectomy or bilateral oophorectomy or tubal ligation) or menopause (at least 1 year without menses or 6 months without menses and a follicle stimulating hormone [FSH] >40 milli-international Units per milliliter [mIU/mL]).

- Have a body weight >50 kilogram (kg).

- Have clinical laboratory test results within normal reference range for the population or investigator site, or results with acceptable deviations that are judged to be not clinically significant by the investigator (potassium, magnesium, and calcium values must be within the normal range).

- Have venous access sufficient to allow blood sampling as per the protocol.

- Have normal blood pressure and pulse rate (sitting position) as determined by the investigator.

- Are reliable and willing to make themselves available for the duration of the study and are willing to follow study procedures.

- Have given written informed consent approved by Lilly and the ethical review board (ERB) governing the site.

Exclusion Criteria:

- Are currently enrolled in, or discontinued within the last 30 days from, a clinical trial involving an investigational drug or device or off-label use of a drug or device other than the study drug, or are concurrently enrolled in any other type of medical research judged not to be scientifically or medically compatible with this study.

- Have known allergies to LY2216684, lorazepam, benzodiazepines, or related compounds.

- Are persons who have previously completed or withdrawn from this study or any other study investigating LY2216684 within 6 months prior to screening.

- Have an abnormality in the 12-lead electrocardiogram (ECG) that, in the opinion of the investigator, increases the risks associated with participating in the study.

- Have a history of or current cardiovascular, respiratory, hepatic, renal, gastrointestinal, endocrine, hematological, or neurological disorders capable of significantly altering the absorption, metabolism, or elimination of drugs; of constituting a risk when taking the study medication; or of interfering with the interpretation of data.

- Have a history or show evidence of significant active neuropsychiatric disease or have a history of suicide attempt or ideation.

- Regularly use known drugs of abuse and/or show positive findings on urinary drug screening.

- Show evidence of human immunodeficiency virus (HIV) and/or positive human HIV antibodies.

- Show evidence of hepatitis C and/or positive hepatitis C antibody.

- Show evidence of hepatitis B and/or positive hepatitis B surface antigen.

- Are women with a positive pregnancy test or women who are lactating.

- Intend to use over-the-counter or prescription medication (including hormonal contraceptives) within 14 days prior to dosing unless deemed acceptable by the investigator and Sponsor's medical monitor, except for influenza vaccinations.

- Use of any drugs or substances that are known to be substrates, inducers, or inhibitors of Uridine 5'-diphospho -glucuronosyltransferase (UGT) within 30 days prior to dosing.

- Have donated blood of more than 500 mL within the last month.

- Have an average weekly alcohol intake that exceeds 14 units per week, or are unwilling to stop alcohol consumption 48 hours prior to each study period and while resident at the clinical research unit (CRU) (1 unit = 12 ounces (oz) or 360 millimeters (mL) of beer; 5 oz or 150 mL of wine; 1.5 oz or 45 mL of distilled spirits).

- Consume 5 or more cups of coffee (or other beverages of comparable caffeine content) per day, on a habitual basis, or any participants unwilling to adhere to study caffeine restrictions.

- Have used any tobacco-containing or nicotine-containing products (including but not limited to cigarettes, pipes, cigars, chewing tobacco, nicotine patches, nicotine lozenges, or nicotine gum) within 6 months prior to enrollment.

- Have consumed grapefruit or grapefruit-containing products 7 days prior to enrollment and during the study.

- Have a documented or suspected history of acute narrow angle glaucoma.

- Have Gilbert's Syndrome

- Participants determined to be unsuitable by the investigator for any reason.

Study Design


Intervention

Drug:
LY2216684
Administered orally
Placebo
Administered orally
Lorazepam
Administered orally

Locations

Country Name City State
United Kingdom For additional information regarding investigative sites for this trial, contact 1-888-545-5972 Mon - Fri, 9 AM to 4 PM or 1-877-CTLILLY (1-877-285-4559, 1-317-615-4559) Mon - Fri, 9 AM to 5 PM Eastern Time or speak with your personal physician. Leeds

Sponsors (1)

Lead Sponsor Collaborator
Eli Lilly and Company

Country where clinical trial is conducted

United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary Pharmacokinetics of Lorazepam, Maximum Plasma Concentration (Cmax) The geometric least squares mean and 90% Confidence Interval are presented. Geometric least squares mean corrected for participant, treatment and random error. Predose, 1, 2, 3, 4, 6, 8, 12, 24, 48, 72 and 96 hours post lorazepam dose
Primary Pharmacokinetics of Lorazepam, Time to Maximum Plasma Concentration (Tmax) Predose, 1, 2, 3, 4, 6, 8, 12, 24, 48, 72 and 96 hours post lorazepam dose
Primary Pharmacokinetics of Lorazepam, Area Under the Plasma Concentration Curve (AUC) From Time 0 to Infinity (8) The geometric least squares mean and 90% Confidence Interval are presented. Geometric least squares mean corrected for participant, treatment and random error. Predose, 1, 2, 3, 4, 6, 8, 12, 24, 48, 72 and 96 hours post lorazepam dose
Secondary Change From Baseline in Cognitive Function-Simple Reaction Time Participants were instructed to press the 'Yes' response button as quickly as possible every time the word 'Yes' was presented on the computer screen. Fifty stimuli were presented with a varying inter-stimulus interval of between 1 and 3.5 seconds. Participant's reaction time to the stimulus was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Digit Vigilance Targets Detected A target digit was pseudo-randomly selected and constantly displayed to the right of the computer screen. A series of 450 digits was then presented in the center of the computer screen at the rate of 150 per minute. The participant was required to press the 'Yes' button as quickly as possible every time a digit in the series matched the target digit. There were 45 targets. Percentage of target digits correctly detected was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Digit Vigilance Speed A target digit was pseudo-randomly selected and constantly displayed to the right of the computer screen. A series of 450 digits was then presented in the center of the computer screen at the rate of 150 per minute. The participant was required to press the 'Yes' button as quickly as possible every time a digit in the series matched the target digit. There were 45 targets. Speed at which a participant detected target digits was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Digit False Alarms A target digit was pseudo-randomly selected and constantly displayed to the right of the computer screen. A series of digits were then presented in the center of the computer screen at the rate of 150 per minute. The participant was required to press the 'Yes' button as quickly as possible every time a digit in the series matched the target digit. There were 45 targets. The number of false alarms (incorrect 'Yes' responses) was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Choice Reaction Time Participants were required to respond to the words 'Yes' and 'No' as they appeared on the computer screen by pressing the corresponding button as quickly as possible. There were 50 trials during which each stimulus word was chosen randomly with equal probability; there was a varying inter-stimulus interval of between 1 and 3.5 seconds. The time required to respond was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Choice Reaction Time Accuracy Participants were required to respond to the words 'Yes' and 'No' as they appeared on the computer screen by pressing the corresponding button as quickly as possible. There were 50 trials during which each stimulus word was chosen randomly with equal probability; there was a varying inter-stimulus interval of between 1 and 3.5 seconds. The percentage of correct responses was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Numeric Working Memory Sensitivity Index (SI) Working memory is a sum of accuracy measures from the numeric and spatial working memory tasks (sensitivity index [SI]). Working Memory SI is based on how fast the participant responds correctly and how many are correct responses. A high score reflects someone able to hold in memory for a prolonged period. A negative change from baseline reflects impairment compared to baseline.
A series of 5 digits were presented on a computer screen, one every 1.15 seconds, for the participant to hold in memory. This was followed by a series of 30 probe digits for each of which the participant had to decide whether it had appeared in the original series of digits and press the corresponding 'Yes' or 'No' response button as quickly as possible. This procedure was repeated 2 times using 2 different series and probes. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time.
Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Numeric Working Memory Speed A series of 5 digits were presented on a computer screen, one every 1.15 seconds, for the participant to hold in memory. This was followed by a series of 30 probe digits for each of which the participant had to decide whether it had appeared in the original series of digits and press the corresponding 'Yes' or 'No' response button as quickly as possible. This procedure was repeated a further 2 times using 2 different series and probes. The time required to press the corresponding 'Yes' or 'No' response button in response to the probe digit is presented. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Immediate Word Recall Accuracy The participant was given a series of words to commit to memory. Immediately after the last word was presented, the participant was given 1 minute to write as many of the words as possible in any order on a sheet of paper. The percentage of words correctly recalled (present on the original list of words) was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Immediate Word Recall Errors The participant was given a series of words to commit to memory. Immediately after the last word was presented, the participant was given 1 minute to write as many of the words as possible in any order on a sheet of paper. The number of words incorrectly recalled (not on the original list of words) was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Delayed Word Recall Accuracy The participant was given a series of words to commit to memory. After a delay of approximately 15-20 minutes, the participant was given 1 minute to write as many of the words as possible in any order on a sheet of paper. The percentage of words correctly recalled (present on the original list of words) was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Delayed Word Recall Errors The participant was given a series of words to commit to memory. After a delay, the participant was given 1 minute to write as many of the words as possible in any order on a sheet of paper. The number of incorrect words was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Word Recognition Sensitivity Index (SI) Word Recognition SI is based on how fast the participant responds correctly and how many are correct responses. SI ranging from zero (chance performance) to one (perfect accuracy). Higher SI indicates better cognitive function. A negative change from baseline reflects impairment compared to baseline.
The original words from Word Presentation plus 15 distractor words were presented one at a time in a randomized order. For each word, the participant was required to indicate whether they recognized it from the original list of words by pressing the corresponding 'Yes' or 'No' button as quickly as possible. Following each response, there was a delay of 1 second before the next word was presented. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time.
Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Word Recognition Speed The original words from Word Presentation plus 15 distractor words were presented one at a time in a randomized order. For each word, the participant was required to indicate whether they recognized it from the original list of words by pressing the corresponding 'Yes' or 'No' button as quickly as possible. Following each response, there was a delay of 1 second before the next word was presented. The time required to press the corresponding 'Yes' or 'No' response button in response to the word was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Picture Recognition Sensitivity Index (SI) Picture Recognition SI is based on how fast the participant responds correctly and how many are correct responses. SI ranging from zero (chance performance) to one (perfect accuracy). Higher SI indicates better cognitive function. A negative change from baseline reflects impairment compared to baseline.
The original pictures from Picture Presentation plus 20 distractor pictures were presented one at a time. For each picture, the participant was required to indicate whether they recognized it from the original series of pictures by pressing the corresponding 'Yes' or 'No' button as quickly as possible. Following the response, there was a delay of 1 second before the next pictures was presented. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time.
Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Picture Recognition Speed The original pictures from Picture Presentation plus 20 distractor pictures were presented one at a time. For each picture, the participant was required to indicate whether they recognized it from the original series of pictures by pressing the corresponding 'Yes' or 'No' button as quickly as possible. Following the response, there was a delay of 1 second before the next pictures was presented. The time required to press the corresponding 'Yes' or 'No' response button in response to the picture was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Tracking Average Distance From Target The participant used a joystick to track a randomly moving target on the computer screen. The distance from the target was measured. Participant's response was measured twice. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Postural Stability The ability to stand upright without moving was assessed using equipment modeled on the Wright Ataxia-meter. To measure movements, a cord was attached to the participant who was required to stand for one minute, as still as possible, with feet apart and eyes closed. The amount of sway is expressed as the total angular movement calibrated in units of one-third degree of angle of sway.
The amount of sway is expressed as the total angular movement in the antero-posterior plane and calibrated in units of one-third degree of angle of sway. Higher result indicates better postural stability. A negative change from baseline reflects impairment compared to baseline. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time.
Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Self-rated Alertness The participant was required to rate how they felt "at this moment" on sixteen 10 centimeter visual analogue scales. The scale endpoints were anchored using polar word pairs such as 'drowsy-alert', 'clumsy-well coordinated', 'mentally slow-quick witted' and 'incompetent-proficient'. Responses from the 16 scales were scored to yield 3 main factors: Self-rated Alertness, Self-rated Contentment, and Self-rated Calmness. The possible range of scores are 0 to 100 for each factor and are represented in millimeters on the 10 centimeter line with higher numbers indicating greater alertness. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Self-rated Contentment The participant was required to rate how they felt "at this moment" on sixteen 10 centimeter visual analogue scales. The scale endpoints were anchored using polar word pairs such as 'drowsy-alert', 'clumsy-well coordinated', 'mentally slow-quick witted' and 'incompetent-proficient'. Responses from the 16 scales were scored to yield 3 main factors: Self-rated Alertness, Self-rated Contentment, and Self-rated Calmness. The possible range of scores are 0 to 100 for each factor and are represented in millimeters on the 10 centimeter line with higher numbers indicating greater contentment. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
Secondary Change From Baseline in Cognitive Function-Self-rated Calmness The participant was required to rate how they felt "at this moment" on sixteen 10 centimeter visual analogue scales. The scale endpoints were anchored using polar word pairs such as 'drowsy-alert', 'clumsy-well coordinated', 'mentally slow-quick witted' and 'incompetent-proficient'. Responses from the 16 scales were scored to yield 3 main factors: Self-rated Alertness, Self-rated Contentment, and Self-rated Calmness. The possible range of scores are 0 to 100 for each factor and are represented in millimeters on the 10 centimeter line with higher numbers indicating greater calmness. Least squares means were adjusted for baseline, period, sequence, time, treatment and treatment*time. Baseline, 2, 4, 8 hours on Day 3
See also
  Status Clinical Trial Phase
Recruiting NCT05537558 - Precision Medicine for the Prediction of Treatment (PROMPT) Response (PROMPT)
Terminated NCT02192099 - Open Label Extension for GLYX13-C-202, NCT01684163 Phase 2
Completed NCT03142919 - Lipopolysaccharide (LPS) Challenge in Depression Phase 2
Recruiting NCT05547035 - Identification of Physiological Data by a Wearable Monitor in Subjects Suffering From Major Depression Disorders N/A
Terminated NCT02940769 - Neurobiological Effects of Light on MDD N/A
Recruiting NCT05892744 - Establishing Multimodal Brain Biomarkers for Treatment Selection in Depression Phase 4
Recruiting NCT05537584 - SMART Trial to Predict Anhedonia Response to Antidepressant Treatment Phase 4
Active, not recruiting NCT05061706 - Multicenter Study of Lumateperone as Adjunctive Therapy in the Treatment of Patients With Major Depressive Disorder Phase 3
Completed NCT04479852 - A Study of the Safety and Efficacy of SP-624 in the Treatment of Adults With Major Depressive Disorder Phase 2
Recruiting NCT04032301 - Repeated Ketamine Infusions for Comorbid PTSD and MDD in Veterans Phase 1
Recruiting NCT05527951 - Enhanced Measurement-Based Care Effectiveness for Depression (EMBED) Study N/A
Completed NCT03511599 - Cycloserine rTMS Plasticity Augmentation in Depression Phase 1
Recruiting NCT04392947 - Treatment of Major Depressive Disorder With Bilateral Theta Burst Stimulation N/A
Recruiting NCT05895747 - 5-HTP and Creatine for Depression R33 Phase Phase 2
Recruiting NCT05273996 - Predictors of Cognitive Outcomes in Geriatric Depression Phase 4
Recruiting NCT05813093 - Interleaved TMS-fMRI in Ultra-treatment Resistant Depression N/A
Recruiting NCT05135897 - The Neurobiological Fundaments of Depression and Its Relief Through Neurostimulation Treatments
Enrolling by invitation NCT04509102 - Psychostimulant Augmentation of Repetitive TMS for the Treatment of Major Depressive Disorder Early Phase 1
Recruiting NCT06145594 - EMA-Guided Maintenance TMS for Depression N/A
Recruiting NCT06026917 - Assessing Dopamine Transporter Occupancy in the Patients With Depression Brain With Toludesvenlafaxine Hydrochloride Extended-Release Tablets Using 11C-CFT Positron Emission Tomography (PET) Phase 4