Clinical Trials Logo

Aneurysm clinical trials

View clinical trials related to Aneurysm.

Filter by:

NCT ID: NCT05309707 Recruiting - Clinical trials for Cardiovascular Diseases

ENDOBARC-S Study: "Endovascular Branched Stent-grafts for Aortic ARCh Pathologies in Spain"

Start date: January 1, 2022
Phase:
Study type: Observational [Patient Registry]

The ENDOBARC-S post-market clinical follow-up study is undertaken to evaluate the prevention of death related to aortic arch pathologies when treated by branch stent graft systems (Nexus stent-graft system®, Relay Branch® or Zenith arch branch graft®), with proximal landing at zone 0. The secondary objective is to evaluate the safety and clinical performance of the studied devices.

NCT ID: NCT05305378 Not yet recruiting - Clinical trials for Aneurysm, AVM, Dural Arteriovenous Fistula, Glioma, Meningioma, Metastasis, Bypass

Intraoperative Laser Speckle Contrast Imaging of Cerebral Blood Flow

Start date: April 15, 2022
Phase: N/A
Study type: Interventional

The purpose of the proposed study is to investigate the usefulness of laser speckle contrast imaging (LSCI) compared to indocyanine green angiography (ICGA). We will collect data from a wide variety of neurovascular surgical procedures to determine when the technology is the most clinically useful. The intraoperative LSCI system provides high resolution images of blood flow in real-time without tissue contact and without the need for an exogenous contrast agent. Further study is needed to gain a better understanding of the use of the technique during surgery, but initial results suggest that the ability to identify blood flow changes with immediate feedback to the surgeon could be a significant advantage during many procedures.

NCT ID: NCT05304026 Recruiting - Clinical trials for Abdominal Aortic Aneurysm

Optimizing CO2 Injection Technique for EVAR

Start date: January 1, 2021
Phase:
Study type: Observational

Automated carbon dioxide (CO2) angiography is considered a safe diagnostic alternative to standard iodinated contrast medium (ICM) for endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA), especially in patients with preoperative renal function impairment. Recent literature experiences describe the use of automated CO2 angiography in EVAR. One of the main issues of CO2 angiography is the inability to detect the origin of the lowest renal artery (proximal neck visualization) that was estimated up to 38%. In these experiences, the CO2 automated angiography is usually performed by a 5F pigtail catheter placed at renal arteries level. The aim of the study is to evaluate the efficacy of a new automated CO2 injection technique by a 5F introducer (single hole catheter) positioned at the distal level of the proximal neck in detecting both renal arteries in the first diagnostic and completion angiographies.

NCT ID: NCT05287828 Completed - Aortic Aneurysm Clinical Trials

Validation of a Software and the Follow-up of Anteropoterior Migration of Stent

ASMOT
Start date: June 16, 2022
Phase:
Study type: Observational

The treatment of aortic aneurysms is today based on different indicators (diameters, lengths, angles, volumes of the arteries) measured on CT scan images. Several indicators are time consuming and complicatated to measure. They demand training and practice. Nurea is developing a software for automatic measurement of these indicators, PRAEVAorta® 2, to facilitate and assist the physician in his clinical routine. The purpose of this study is to compare the analysis realised by the software PRAEVAorta® 2 with the analysis realised by the healthcare professional on retrospective CT scan images. Contrasted and non-contrasted, pre-operation or post-operation CT scans from 50 patients will be analysed. The main objectif is to validate the accuracy of the software by demonstrating its adequacy to the standard method of analysis. The second objectives are the following: - Evaluate the security of the software PRAEVAorta® 2 - Evaluate the unanticipated risks related to the use of the software - Validate the accessory PRAEVAorta® Web We make the following assumption : 90% of the patients show 90% of adequacy to the healthcare professional analysis

NCT ID: NCT05279274 Not yet recruiting - Clinical trials for Abdominal Aortic Aneurysm Without Rupture

ShorT Stay Aneurysm Repair Study

STAR
Start date: November 1, 2022
Phase:
Study type: Observational

A prospective observational cohort study to assess the eligibility, uptake, viability, acceptability, safety, and cost of a ShorT stay (23-hour) Aneurysm Repair (STAR) pathway. Outcomes will be collected for up to 1 year.

NCT ID: NCT05276934 Recruiting - Clinical trials for Intracranial Aneurysm

Brain Imaging After Non-traumatic Intracranial Hemorrhage (SAVEBRAINPWI)

SAVEBRAINPWI
Start date: March 1, 2022
Phase:
Study type: Observational

The study is an observational prospective evaluation of an approved and unchanged clinical management, evaluating different diagnosis methods to assess brain perfusion in patients with an aneurysmal or AVM-related intracranial hemorrhage

NCT ID: NCT05275296 Recruiting - Clinical trials for Cardiovascular Diseases

Registration Trial of the Intracranial Visualized Stent for the Wide-necked Intracranial Aneurysms

PROMISE
Start date: January 24, 2022
Phase: N/A
Study type: Interventional

A registration trial of the Intracranial Visualized stent in the treatment of wide-necked intracranial aneurysms

NCT ID: NCT05269498 Completed - Cranial Aneurysm Clinical Trials

Navigation Support With Mixed Reality With CORTEXPLORER MED

CXmed
Start date: June 8, 2022
Phase: N/A
Study type: Interventional

During the last 15 years, neuronavigation has become an essential neurosurgical tool for pursuing minimal invasiveness and safety. One drawback of such devices is the fact, that the neurosurgeon has to look away from the surgical field onto a dedicated workstation screen. Additionally, the operator is required to transfer this information from the "virtual" environment of the navigation system to the real surgical field - whereas the real patient may be fixated and positioned differently compared to the visualization on the screen. Mixed-reality may have the potential to support this, by merging data from the real environment with virtual information and vice-versa. In the context of surgical navigation, the main goal of mixed reality systems is to provide a real-time updated 3D virtual model of anatomical details, overlaid on the real surgical field. In this sense, the mixed reality is the process of enrichment of reality with additional virtual contents. This clinical investigation aims at the collecting of clinical data about the mixed-reality supported planning, the registration accuracy and overall precision of the navigation system and the clinical outcome.

NCT ID: NCT05266781 Completed - Clinical trials for Thoracoabdominal Aortic Aneurysms

A PROpensity Score Matching Analysis on ENDovascular vs Open Thoraco-Abdominal Aortic Aneurysm Repair (PRO-ENDO TAAA Study)

PRO-ENDO TAAA
Start date: April 1, 2022
Phase:
Study type: Observational

The purpose of the registry is to compare the surgical and endovascular approaches to the treatment of thoracoabdominal aortic aneurysms.

NCT ID: NCT05257824 Recruiting - Clinical trials for Endovascular Procedures

Optimal Duration of Dual Antiplatelet Therapy After Stent-assisted Coiling

Start date: June 23, 2022
Phase: Phase 4
Study type: Interventional

Comparison of duration of dual antiplatelet therapy after stent-assisted coiling of unruptured intracranial aneurysms