View clinical trials related to Tachycardia, Ventricular.
Filter by:The study evaluates 3 different populations: It is an open, randomized, parallel-group study comparing the effectiveness of intravenous (iv) ajmaline with currently used antiarrhythmic drugs in the acute treatment of : 1. recent-onset atrial fibrillation versus iv flecainide 2. sustained monomorphous ventricular tachycardia versus iv procainamide The study also evaluates in an open, randomized, crossover study, the use of iv ajmaline versus iv flecainide in the diagnosis of Brugada syndrome
To investigate changes in HRV during the time before a spontaneous episode of ventricular tachyarrhythmia.
The MADIT-II trial has shown that patients with severely reduced left ventricular ejection fraction (LVEF) post myocardial infarction benefit from the implantable cardioverter-defibrillator (ICD). However, retrospective analyses of the MADIT-II data have revealed a significantly increased morbidity and mortality in patients with appropriate ICD therapy: Appropriate ICD therapy is associated with 3.3-fold increased all-cause mortality, and the risk of a first heart failure hospitalization is 90% higher after 1st appropriate ICD therapy. Hence, the 1st appropriate therapy might indicate the necessity and utility of further clinical diagnostics and therapy in these patients. This trial is designed to (i) improve the knowledge of the group characteristics of patients suffering from 1st appropriate ICD therapy, (ii) but moreover to take additional therapeutic steps to reduce the mortality of this patient population.
Many arrhythmias detected in the ventricular fibrillation (VF)-zone picture monomorphic ventricular tachycardia (VT) and, hence, could be terminated by antitachycardia pacing (ATP) treatment. Advantages of successful ATP are the painlessness termination and the shortened duration of arrhythmia. The ATP One Shot algorithm is integrated in the latest family of implantable cardioverter defibrillators (ICDs) from BIOTRONIK (Lumax). It allows a single delivery of ATP before charging capacitors to terminate lethal arrhythmia by painful shock. The present study evaluates the efficacy of the ATP One Shot algorithm for the termination of fast VT episodes. 200 patients with secondary prophylactic ICD indication will be followed for 18 months. Spontaneous episodes detected in the VF-zone of the ICD will be evaluated with regard to cycle length, episode duration and course of device therapy.
The COGENT-4 Field Following Study will evaluate the clinical performance of the Boston Scientific TELIGEN 100 HE Implantable Cardioverter Defibrillator (ICD), the COGNIS 100 HE Cardiac Resynchronization Therapy ICD (CRT-D) systems and the RELIANCE 4-SITE defibrillation lead (when available). An optional sub-study will also evaluate the clinical performance of the Reverse Mode Switch (RMS) feature in the TELIGEN 100 HE DR ICD.
The purpose of this study is to determine if remote monitoring of implantable cardioverter defibrillators (ICD), compared with quarterly device interrogations in clinic, will improve patients' outcomes and satisfaction and will reduce health care costs.
The ABCD clinical study (ClinicalTrials.gov Identifier NCT00187291) was designed to determine if a T-Wave Alternans (TWA) test is equivalent to an Electrophysiology Study (EPS) in predicting life-threatening heart rhythms in patients with ischemic heart disease, left ventricular dysfunction, and non-sustained tachycardia. The purpose of the ABCD Genetic sub-study is to identify genetic markers that predict TWA status and arrhythmia risk in this same population.
This study is intended to look at the effect of the SJM vibrating Patient Notifier™ system, which will warn the patient of possible failures of the implanted system, on reducing patient device related anxiety
Re-hospitalizations or deaths by worsening heart failure are often preceded by distinct trends of clinical parameters such as atrial or ventricular arrhythmia, activity, heart rate variability, or ventricular ectopy. The Home Monitoring™ capability offered by BIOTRONIK active implants has the potential to detect some of these trends early and thus to offer the possibility to intervene in time for prevention of fatal worsening of heart failure. To investigate the predictive value of Home Monitoring parameters, patients with symptomatic heart failure and reduced ejection fraction receiving an implantable cardioverter-defibrillator (ICD) or an ICD in combination with cardiac resynchronization therapy (CRT-D) will be randomized between prospective patient management by Home Monitoring analysis or standard care. The influence of Home Monitoring on the clinical status of heart failure patients will be assessed.
The long-chain n-3 polyunsaturated fatty acids (PUFA), eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), appear to offer protection against sudden cardiac death and ventricular arrhythmias. EPA and DHA are essential fatty acids which are incorporated into cellular membranes after regular ingestion of fatty fish or fish oil. This study investigates a possible acute effect of intravenous infusion of n-3 PUFA on inducibility of ventricular tachycardia (VT) in patients with an ICD-pacemaker. The hypothesis is that an acute rise in the concentration of n-3 PUFA in plasma will increase the electric stability of the myocardial cells, so that VT is more difficult to induce. In a randomized, placebo-controlled, double-blind, crossover study, a lipid emulsion with a high content of n-3 PUFA (or placebo: isotonic saline) will be administered intravenously before a non-invasive electrophysiologic examination performed via the ICD and following a predefined protocol. The main outcome is inducibility of VT. If sustained VT is induced in a patient after both n-3 PUFA and placebo, the strength of the required stimulus after n-3 PUFA and after placebo is compared.