Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT01314456
Other study ID # NaviGo- 01
Secondary ID 3D TRUS Bx recor
Status Not yet recruiting
Phase N/A
First received March 11, 2011
Last updated March 14, 2011
Start date March 2011
Est. completion date December 2011

Study information

Verified date March 2011
Source HaEmek Medical Center, Israel
Contact Michael mo Cohen, MD
Phone +972-544-764444
Email dr.m.cohen@gmail.com
Is FDA regulated No
Health authority Israel: Ethics Commission
Study type Interventional

Clinical Trial Summary

Prostate biopsy is performed by multiple consecutive biopsy needle insertion into the prostate gland under a trans-rectal ultrasound probe guidance.

Today, the performing physician navigates the needle using a momentary 2D ultrasound image (longitudinal and transverse B mode) without any record of the full prostate boundaries or previous biopsies' location.

This study's Objectives are to record the trans-rectal biopsy procedure including the initial scan and the needle biopsy location and to modulate a 3D model of the prostate with accurate display the locations of the various biopsies taken during the procedure.


Description:

3D record of a trans-rectal prostate biopsy

Clinical Study Protocol Study no: NaviGo -01

Sponsor: UC-CARE. Apollo Bld. 3rd fl. Hi-Tech Park P.O.Box 67 Yokneam 20692 Israel Tel: 972-4-9097427 Fax:972-4-9937323

Feb. 2011 Version: 02

ABBREVIATIONS:

3D: 3 Dimensional 2D: 2 Dimensional TR: Trans-Rectal

1. PROTOCOL SUMMARY Title: 3D recording of a trans-rectal prostate biopsy Device: Navigo™

Study Objectives: 1) To record the trans-rectal biopsy procedure including the initial scan and the needle biopsy location 2) To modulate a 3D model of the prostate and accurately display the locations of the various biopsies taken during the procedure

Study Design: Open prospective study. Recruitment target: 50 patients

Study Population: Patients undergoing trans-rectal prostate biopsy

Study endpoint:

Accurate 3D modelling of the prostate and the biopsy procedure

Principal Investigator

Co-operating Company and Sponsor: Dr. Michael Cohen

UC-CARE. Yokneam, Israel

2. INTRODUCTION Prostate biopsy is performed by multiple consecutive biopsy needle insertion into the prostate gland under the trans-rectal ultrasound probe guidance. The needle is inserted through a designated needle guide on the ultrasound probe, through the rectum wall and into the prostate gland.

Today, the performing physician navigates the needle using a momentary 2D ultrasound image (longitudinal and transverse B mode) without any record of the full prostate boundaries or previous biopsies' location. By recording the procedure the Navigo™ system will generate and display in off-line an accurate 3D model of the prostate and position the biopsies taken in the prostatic volume.

3. OBJECTIVES AND RATIONALE 3.1 Study objectives

1) To record the trans-rectal biopsy procedure including the initial scan and the needle biopsy location 2) To modulate a 3D model of the prostate and accurately display the locations of the various biopsies taken during the procedure

3.2 Rationale

The Navigo™ system is a noninvasive system that allows the physician to accurately record the biopsy procedure without changing the imaging system, the biopsy routine or the techniques used today to scan and guide the biopsy needle insertion. The ability to create an accurate 3D model of the prostate and accurately position the biopsy needle location will allow the performing physician a more precise navigation and easier and more accurate biopsy within the prostate volume and enable a better analysis of the procedure and the pathological results, hence improved clinical outcomes with intended therapy or surveillance ( i.e.- prepare for follow-up biopsy procedure if needed).

4. DEVICE DESCRIPTION AND INTENDED USE The Navigo™ system is comprised of two main elements: a standard laptop computer with a digitizer input to record incoming video input (from the ultrasound system), and an electro-magnetic 3D tracking system. The 3D tracking system is connected via USB to the laptop computer, the transmitter is placed beneath the patient's mattress and two sensors are attached,- one to the ultrasound probe (at the base/ non invasive part of the probe) and the other to the patient's back.

The Navigo™ system tracks and records the location of the ultrasound probe and the incoming video from the ultrasound system. The patient's movement is recorded and compensated when the ultrasound images are placed with reference to each other. In post procedure, the physician defines the boundaries of the prostate on selected ultrasound images and a 3D model of the prostate is displayed with all recorded biopsy specimens' locations displayed in the prostatic volume. The physician will be able to examine in post analysis the scattering quality of the biopsy specimens in the prostatic volume and update the pathology results. The 3D model can be rotated, manipulated and displayed in the physician's preferable choice.

The Navigo™ system is intended to record and display in 3D the biopsy procedure of any patient undergoing a prostate trans-rectal biopsy. The Navigo™ system is intended to record all the data from the initial scan, the volume measurements, and the biopsy needle insertion. All the images are saved and can be reviewed in post analysis, the needle location can be updated according to the physician's marking on the recorded ultrasound image and the pathology results will be displayed in color on the 3D model.

5. METHODS AND PROCEDURES 5.1 Study Design

The study is an open prospective study

- Examination procedure:

o The trans-rectal ultrasound guided prostate biopsy procedure will be conducted with no change what so ever from the currently conducted procedure.

o The exceptions to the normal procedure is the addition of the flat transmitter under the patients mattress, the 2 external attached sensors and the recording of the procedure via the video-out put of the ultrasound using the Navigo™ system.

o The 3D model will be compared with the recorded ultrasound images by the physician

- The recorded data will be processed off-line (post biopsy /off-line analysis).

- The analysis of the results will be completed in post procedure by the physician.

5.2 Trial Procedure

- A short one-time calibration of the Navigo™ system with the ultrasound system will be completed by a trained technician (UC-CARE's technician)

- The transmitter will be placed beneath the patient's mattress and the body sensor will be attached to the patients' back using a regular disposable medical sticker.

- The trans-rectal ultrasound probe will be held by the physician and controlled throughout the procedure according to the existing current biopsy protocol, without any alterations.

- The common ultrasound video output will be connected to the video input of the Navigo™ system

- Patient's identifications will be filled to allow proper post examination analysis

- Following the initial scan of the prostate and the volume measurements the Navigo™ system will record the data and store it for post analysis

- In the 3D biopsy screen a 3D model of the prostate will be displayed with record of all needle biopsy locations as recorded during the procedure.

- The pathology results can be loaded to the Navigo™ system and displayed on the 3D model

6. SUBJECT POPULATION SELECTION 6.1 Inclusion Criteria

• Eligibility -

- Age 18 years or older

- Planned for trans-rectal prostate biopsy

- Signed informed consent

6.2 Exclusion criteria

- Patient's unwilling to participate

- Patients with metal prosthetics

7. POTENTIAL BENEFITS TO SUBJECTS No immediate benefits are expected to be gained by the subjects participating in the study as the 3D modeling and the display is completed post procedure. The procedure will be carried out exactly as it would have been without the Navigo™ system participating in the biopsy procedure. The post procedure 3D model display with the biopsy specimen's location may enable better data analysis.

8. POTENTIAL RISKS TO SUBJECTS The Navigo™ system is a passive system that does not require any change in the procedure performed today. The various components do not come in direct contact with the patient or the physician and the computer and 3D tracking system are well within the required safety protocols.

The Navigo system has been approved by the CE. The 3D tracking system is approved by the FDA for medical use and is classified as Type CF which is the most stringent classification, being required for those applications where the applied part is in direct conductive contact with the heart or other applications as considered necessary. The 3D tracking system is also part of an approved Helsinki trial in Bnei-zion hospital (monitoring of the birth progress, trial initiated by Dr. Yoav Paltieli) Adverse effects are not expected according to the accumulated experience with the 3D tracking system. Similarly, the Navigo™ system is not expected to add to the procedure any pain or discomfort to the patients.

9. SUBJECT RECUITMENT Study population will be recruited from the pool of patients who are scheduled for trans-rectal biopsy procedure

10. DATA ANALYSIS

The data analysis will include the following steps:

• Post procedure display of the prostate's 3D model and the location of the various biopsy specimens taken during the procedure in the prostatic volume

• Comparison of the results with the physician analysis of the specimens location as derived from the images themselves

11. REFERENCE

1. Ultrasonography and biopsy of the prostate. Ramey et al., Chapter 92. Campbell-Walsh Urology. Elsevier 2007.

2. Prostate biopsies guided by three-dimensional real-time (4-D) transrectal ultrasonography on a phantom: comparative study versus two-dimensional transrectal ultrasound-guided biopsies. Long, Eur.Urol, 2007 Oct;52(4):1097-104.

3. Extended and saturation prostatic biopsy in the diagnosis and characterisation of prostate cancer: a critical analysis of the literature. Scattoni , Eur Urol. 2007 Nov;52(5):1309-22 .

4. Appropriate Patient Selection in the Focal Treatment of Prostate Cancer: The Role of Transperineal 3-Dimensional Pathologic Mapping of the Prostate—A 4-Year Experience. Barzell. Urology 70 ( suppl. 6a) dec. 2007

5. The lottery of conventional prostate biopsy. Andriole. Nat. Rev. urol. P-189 , V-6, Apr. 2009

6. Will focal therapy become a standard of care for men with localized prostate cacner? Ahmed. Nat. Clin.Pract. Oncol. 4(11)


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 50
Est. completion date December 2011
Est. primary completion date December 2011
Accepts healthy volunteers No
Gender Male
Age group 18 Years and older
Eligibility Inclusion Criteria:

- Age 18 years or older

- Planned for trans-rectal prostate biopsy

- Signed informed consent

Exclusion Criteria:

- Patient's unwilling to participate

- Patients with metal prosthetics

Study Design

Allocation: Non-Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Intervention

Device:
NaviGo
Video recording of a normal TRUS guided prostate biopsy with additional 2 , non invasive,electromagnetic sensors attached to the TRUS probe and the patient's back,- to allow for a 3D modeling of the prostate.

Locations

Country Name City State
Israel Dept. of urology , HaEmek medical center Afula

Sponsors (4)

Lead Sponsor Collaborator
HaEmek Medical Center, Israel Barzilai Medical Center, Bnai Zion Medical Center, Meir Medical Center

Country where clinical trial is conducted

Israel, 

Outcome

Type Measure Description Time frame Safety issue
Primary Create 3D model of the prostate and accurately display the locations of the various biopsies taken during the procedure Post procedure ( off-line ) within a 3-5 working days No
See also
  Status Clinical Trial Phase
Recruiting NCT05540392 - An Acupuncture Study for Prostate Cancer Survivors With Urinary Issues Phase 1/Phase 2
Recruiting NCT05613023 - A Trial of 5 Fraction Prostate SBRT Versus 5 Fraction Prostate and Pelvic Nodal SBRT Phase 3
Recruiting NCT05156424 - A Comparison of Aerobic and Resistance Exercise to Counteract Treatment Side Effects in Men With Prostate Cancer Phase 1/Phase 2
Completed NCT03177759 - Living With Prostate Cancer (LPC)
Completed NCT01331083 - A Phase II Study of PX-866 in Patients With Recurrent or Metastatic Castration Resistant Prostate Cancer Phase 2
Recruiting NCT05540782 - A Study of Cognitive Health in Survivors of Prostate Cancer
Active, not recruiting NCT04742361 - Efficacy of [18F]PSMA-1007 PET/CT in Patients With Biochemial Recurrent Prostate Cancer Phase 3
Completed NCT04400656 - PROState Pathway Embedded Comparative Trial
Completed NCT02282644 - Individual Phenotype Analysis in Patients With Castration-Resistant Prostate Cancer With CellSearch® and Flow Cytometry N/A
Recruiting NCT06305832 - Salvage Radiotherapy Combined With Androgen Deprivation Therapy (ADT) With or Without Rezvilutamide in the Treatment of Biochemical Recurrence After Radical Prostatectomy for Prostate Cancer Phase 2
Recruiting NCT06037954 - A Study of Mental Health Care in People With Cancer N/A
Recruiting NCT05761093 - Patient and Physician Benefit/ Risk Preferences for Treatment of mPC in Hong Kong: a Discrete Choice Experiment
Completed NCT04838626 - Study of Diagnostic Performance of [18F]CTT1057 for PSMA-positive Tumors Detection Phase 2/Phase 3
Recruiting NCT03101176 - Multiparametric Ultrasound Imaging in Prostate Cancer N/A
Completed NCT03290417 - Correlative Analysis of the Genomics of Vitamin D and Omega-3 Fatty Acid Intake in Prostate Cancer N/A
Completed NCT00341939 - Retrospective Analysis of a Drug-Metabolizing Genotype in Cancer Patients and Correlation With Pharmacokinetic and Pharmacodynamics Data
Completed NCT01497925 - Ph 1 Trial of ADI-PEG 20 Plus Docetaxel in Solid Tumors With Emphasis on Prostate Cancer and Non-Small Cell Lung Cancer Phase 1
Recruiting NCT03679819 - Single-center Trial for the Validation of High-resolution Transrectal Ultrasound (Exact Imaging Scanner ExactVu) for the Detection of Prostate Cancer
Completed NCT03554317 - COMbination of Bipolar Androgen Therapy and Nivolumab Phase 2
Completed NCT03271502 - Effect of Anesthesia on Optic Nerve Sheath Diameter in Patients Undergoing Robot-assisted Laparoscopic Prostatectomy N/A