Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to evaluate a non-ionizing electromagnetic method to align the prostate treatment site for radiation therapy and to monitor its position throughout radiation therapy delivery. The clinical study involves using an investigational device, the Calypso® 4D Localization System, and requires permanent implantation of three small sensors called Beacon® transponders in the prostate.


Clinical Trial Description

The goal for prostate radiation therapy is to give a high dose of radiation to the prostate and a minimal dose to the healthy tissue around the prostate. It is well known that the prostate moves slightly within the pelvis and that its position varies a few millimeters from day to day. There are several methods used to position the body and the prostate accurately at the beginning of each radiation therapy session.

One of the standard methods is to permanently implant small markers (gold spheres or cylinders) in the prostate and use x-rays in the radiation therapy treatment room to determine whether the markers are in the correct position. If the markers are in the correct position, then the assumption is that the prostate also is in the correct position. If the markers are not in the correct position on the x-ray, then the table that the patient lies on can be shifted so that the markers are in the right place.

In this study the Beacon® transponder will be used in place of the standard gold marker. During the radiation therapy visits, the patient position in the treatment room will be corrected using the Beacon transponder with an investigational system, called the Calypso® 4D Localization System. The Calypso system consists of a flat panel, placed over the pelvis and connected to a computer, which monitors the position of the Beacon transponders within the prostate. During five radiation therapy appointments and one extra visit, the position of the markers in the prostate will be confirmed with x-rays.

The Beacon transponder is a small glass cylinder that contains a tiny electrical circuit. The glass vial is completely sealed and separates the internal components (i.e., the electrical circuit) from the rest of the body. The glass vial is approximately one-third of one inch long and one-tenth of one inch in diameter. Three Beacon transponders will be implanted in the prostate. They will be permanently implanted. ;


Study Design

Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00123838
Study type Interventional
Source Varian Medical
Contact
Status Completed
Phase N/A
Start date July 2005
Completion date September 2008

See also
  Status Clinical Trial Phase
Recruiting NCT05613023 - A Trial of 5 Fraction Prostate SBRT Versus 5 Fraction Prostate and Pelvic Nodal SBRT Phase 3
Recruiting NCT05540392 - An Acupuncture Study for Prostate Cancer Survivors With Urinary Issues Phase 1/Phase 2
Recruiting NCT05156424 - A Comparison of Aerobic and Resistance Exercise to Counteract Treatment Side Effects in Men With Prostate Cancer Phase 1/Phase 2
Completed NCT03177759 - Living With Prostate Cancer (LPC)
Completed NCT01331083 - A Phase II Study of PX-866 in Patients With Recurrent or Metastatic Castration Resistant Prostate Cancer Phase 2
Recruiting NCT05540782 - A Study of Cognitive Health in Survivors of Prostate Cancer
Active, not recruiting NCT04742361 - Efficacy of [18F]PSMA-1007 PET/CT in Patients With Biochemial Recurrent Prostate Cancer Phase 3
Completed NCT04400656 - PROState Pathway Embedded Comparative Trial
Completed NCT02282644 - Individual Phenotype Analysis in Patients With Castration-Resistant Prostate Cancer With CellSearch® and Flow Cytometry N/A
Recruiting NCT06305832 - Salvage Radiotherapy Combined With Androgen Deprivation Therapy (ADT) With or Without Rezvilutamide in the Treatment of Biochemical Recurrence After Radical Prostatectomy for Prostate Cancer Phase 2
Recruiting NCT06037954 - A Study of Mental Health Care in People With Cancer N/A
Recruiting NCT05761093 - Patient and Physician Benefit/ Risk Preferences for Treatment of mPC in Hong Kong: a Discrete Choice Experiment
Completed NCT04838626 - Study of Diagnostic Performance of [18F]CTT1057 for PSMA-positive Tumors Detection Phase 2/Phase 3
Recruiting NCT03101176 - Multiparametric Ultrasound Imaging in Prostate Cancer N/A
Completed NCT03290417 - Correlative Analysis of the Genomics of Vitamin D and Omega-3 Fatty Acid Intake in Prostate Cancer N/A
Completed NCT00341939 - Retrospective Analysis of a Drug-Metabolizing Genotype in Cancer Patients and Correlation With Pharmacokinetic and Pharmacodynamics Data
Completed NCT01497925 - Ph 1 Trial of ADI-PEG 20 Plus Docetaxel in Solid Tumors With Emphasis on Prostate Cancer and Non-Small Cell Lung Cancer Phase 1
Recruiting NCT03679819 - Single-center Trial for the Validation of High-resolution Transrectal Ultrasound (Exact Imaging Scanner ExactVu) for the Detection of Prostate Cancer
Completed NCT03554317 - COMbination of Bipolar Androgen Therapy and Nivolumab Phase 2
Completed NCT03271502 - Effect of Anesthesia on Optic Nerve Sheath Diameter in Patients Undergoing Robot-assisted Laparoscopic Prostatectomy N/A