Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT06359938
Other study ID # Cer22/01
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date June 1, 2024
Est. completion date April 1, 2025

Study information

Verified date April 2024
Source Ceryx Medical Ltd
Contact Susan Peirce, PhD
Phone +44 (0)29 218 44771
Email susan.peirce@wales.nhs.uk
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The goal of this clinical trial is to test a new type of pacemaker in heart failure patients following a heart bypass operation. The new pacemaker restores respiratory sinus arrhythmia which is a natural pattern where the heart rate increases when the participants breathe in and slows down when participants breathe out. The main questions the trial aims to answer are: - Is the new type of pacemaker safe? - Does the new type of pacemaker improve how patients' hearts work (also known as cardiac output)? Participants will have a range of tests before their operation and during their recovery in hospital while participants have the new type of pacemaker in place, and will be monitored very closely. Participants will also receive a phone call 1 month after their surgery. Researchers will compare the new type of heart pacing against standard treatment to see if it is as safe, and if it is any better for patients.


Description:

This is a first-in-human (FIH) clinical investigation of a modification of an existing medical device. It will be a comparative, multicentre, randomised controlled trial (RCT) design. RSA modulated atrial pacing will be compared against monotonic atrial pacing in patients with HFrEF who have had CABG surgery. The purpose of this clinical investigation is to explore the risk/benefit profile of the use of RSA pacing in patients with HFrEF following CABG. Based on the prior animal models the investigators hypothesise an improvement in cardiac function over several days of RSA pacing, with no increase in risk compared to typical pacemaker use. Primary hypothesis - Atrial pacing with additional RSA variability (for up to 10 days) is feasible and safe in patients with heart failure and reduced ejection fraction. The primary outcome is measuring arrhythmia episodes. Secondary hypothesis - Atrial pacing with additional RSA variability improves cardiac function in patients with heart failure and reduced ejection fraction following CABG surgery. The secondary outcomes is measuring cardiac function, cardiac output, apnoea episodes. Respiratory sinus arrhythmia is part of normal physiology and RSA pacing is looking to restore this. In heart failure, RSA is severely reduced. Therefore the investigators have identified that, post-CABG surgery patients with heart failure and reduced ejection fraction are the ideal candidates for this study. Following surgery it is standard of care for a surgeon to leave temporary pacing wires attached to the heart as a precaution and it is not uncommon to leave them in for 10 days or longer. Hence, these temporary wires can be used to deliver RSA pacing. Adjusting pacing rates is common in both implanted or temporary pacemakers. Potential patients awaiting CABG surgery with heart failure with reduced ejection fraction will be identified using two routes - inpatients and outpatients. The investigators would randomly allocate patients to either the RSA external pacemaker box or the normal external pacemaker for a maximum of 10 days. Patients will be connected to nasal prongs to monitor their respiration and in the RSA group, this signal will be fed to the external pacemaker to deliver RSA pacing.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 54
Est. completion date April 1, 2025
Est. primary completion date March 1, 2025
Accepts healthy volunteers No
Gender All
Age group 22 Years and older
Eligibility Inclusion Criteria: - Adult patients (= 22 years) selected for isolated, on-pump coronary artery bypass graft (CABG) - Established diagnosis of heart failure with reduced ejection fraction (HFrEF). - Elective or urgent admission routes - Echocardiography assessment of left ventricular ejection fraction (EF) of 20%-40% (within 1 month of planned surgery) - Sinus rhythm - Any number of coronary vessels replaced. Must include left anterior descending artery. - Able to provide written informed consent Exclusion Criteria: - Requirement for concurrent valve replacement surgery. - Off-pump CABG. - Emergency CABG - History of paroxysmal or permanent atrial fibrillation or flutter - History of atrioventricular-node dependent tachycardia - Patients lacking capacity to consent - Patient testing positive for Covid-19 within 14 days of intended CABG (PCR or lateral flow test) - Intrinsic resting heart rate > 100bpm - Pregnancy - Implanted pacemaker or defibrillator - Failure to obtain Uscom signals

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Atrial pacing with respiratory sinus arrhythmia (RSA) variability
The intervention in this study is a modification of the pacing output from a standard external pacemaker such that it will approximate the RSA variation found in healthy subjects. A pacemaker (PACE204, Osypka Medical AG), similar to those currently in common use in post-CABG patients, will be adapted to receive an additional input signal based on the respiratory signal (Ceryx device). The respiration signal will be combined with the ECG signal to determine the appropriate pacing interval. The pacing impulse will be delivered by the pacemaker unit.
Monotonic right atrial overdrive pacing
Pacing is delivered by a PACE204 pacemaker (Osypka Medical AG) delivering standard monotonic right atrial pacing

Locations

Country Name City State
United Kingdom Cardiff & Vale University Health Board Cardiff

Sponsors (2)

Lead Sponsor Collaborator
Ceryx Medical Ltd Cardiff and Vale University Health Board

Country where clinical trial is conducted

United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary Number of arrhythmia episodes per patient during pacing Any episode of arrhythmia, captured on an ECG between the initiation of pacing (Pacing Day 1) and the post-pacing visit (Day 7 - Post-discharge form hospital ), and lasting 30 seconds or longer, will be recorded. Anonymised ECG extracts will be reviewed by two cardiologists to identify the type of arrhythmia. From start of pacing to end of pacing
See also
  Status Clinical Trial Phase
Completed NCT05077293 - Building Electronic Tools To Enhance and Reinforce Cardiovascular Recommendations - Heart Failure
Completed NCT03614169 - Direct HIS-pacing as an Alternative to BiV-pacing in Symptomatic HFrEF Patients With True LBBB N/A
Recruiting NCT05278962 - HF Patients With LVADs Being Treated With SGLT2i Phase 4
Completed NCT04210375 - Study of JK07 in Subjects With Heart Failure With Reduced Ejection Fraction (HFrEF) Phase 1
Not yet recruiting NCT06433687 - Evaluation of the HekaHeart Platform in Medication Management for Heart Failure Patients
Completed NCT05001165 - Dashboard Activated Services and Tele-Health for Heart Failure N/A
Active, not recruiting NCT03701880 - Early Use of Ivabradine in Heart Failure N/A
Recruiting NCT05650658 - Left vs Left Randomized Clinical Trial N/A
Not yet recruiting NCT06299436 - Hemodynamic Assessment of underLying myocyTe Function in Right Heart Failure
Recruiting NCT05992116 - Iron Deficiency in Patients With Heart Failure and Reduced and Mildly Reduced Ejection Fraction
Recruiting NCT05365568 - Left Bundle Branch Area Pacing for Cardiac Resynchronization Therapy: A Randomized Study N/A
Active, not recruiting NCT05204238 - Follow Up of acuTe Heart failUre: a pRospective Echocardiographic and Clinical Study (FUTURE)
Not yet recruiting NCT04420065 - Effects of Preferential Left Ventricular Pacing on Ventriculoarterial Coupling and Clinical Course of Heart Failure N/A
Terminated NCT03479424 - Home Outpatient Monitoring and Engagement to Predict HF Exacerbation
Completed NCT02113033 - VAgal Nerve Stimulation: safeGUARDing Heart Failure Patients Phase 2
Recruiting NCT03209180 - Immediate Release Versus Slow Release Carvedilol in Heart Failure Phase 4
Recruiting NCT05299879 - Screening for Advanced Heart Failure IN Stable ouTpatientS - The SAINTS Study
Recruiting NCT05637853 - Telemonitored Fast Track Medical Sequencing for Heart Failure With Reduced Ejection Fraction
Completed NCT03870074 - CPET Predicts Long-term Survival and Positive Response to CRT
Recruiting NCT04590001 - Effect of the MobiusHD® in Patients With Heart Failure N/A