Inflammation at Mini-screw Insertion Site Clinical Trial
Official title:
Antibiotic Prophylaxis Prior to the Insertion of Orthodontic Mini-screw Implants: a Randomized Controlled Trial
| Verified date | November 2020 |
| Source | St. Louis University |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Interventional |
The investigators plan to use amoxicillin in capsule form, prepared by a pharmacist, for antibiotic prophylaxis to decrease the failure rate of mini-screw implants temporarily placed in the palate of patients involved in Phase II orthodontics treatments. The mini-screws will be 8 mm long 1.7 mm diameter titanium screws manufactured by Forestadent and are commercially available and currently widely used in orthodontic treatment in both private practice and educational settings. Since antibiotic prophylaxis is considered the standard of care with traditional dental implants, the investigators believe that such prophylaxis will decrease the failure rate of orthodontic mini-screw implants also.
| Status | Completed |
| Enrollment | 31 |
| Est. completion date | November 1, 2020 |
| Est. primary completion date | October 1, 2020 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 12 Years and older |
| Eligibility | Inclusion Criteria: Subjects will be selected for the study based on treatment plans for Phase II orthodontics at SLU CADE orthodontics program, which require the use of palatally placed mini-screw implants for anchorage control. Exclusion Criteria: - Patients with experience in previous MSI placements - allergy to amoxicillin - allergy to Beta-lactam based antibiotics - medical syndrome diagnoses - psychiatric disorders (ADHD, autism, manic-depressive disorder, etc.) - a compromised immune system - impaired or decreased kidney function - Type I or Type II diabetes - patients taking Probenicid or Allopurinol |
| Country | Name | City | State |
|---|---|---|---|
| United States | Saint Louis University Center for Advanced Dental Education | Saint Louis | Missouri |
| Lead Sponsor | Collaborator |
|---|---|
| St. Louis University |
United States,
Berens A, Wiechmann D & Rudiger J. "L'ancrage intra-osseux en orthodontie a' l'aide de mini et de microvis." International Orthodontics (2005) 3: 235-43.
Carano A, Melsen B. Implants in orthodontics. Interview. Prog Orthod. 2005;6(1):62-9. English, Italian. — View Citation
Cope J. "Temporary anchorage devices in orthodontics: a paradigm shift." Seminars in Orthodontics (2005)11:3-9.
Costa A, Raffainl M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg. 1998;13(3):201-9. — View Citation
Esposito M, Grusovin MG, Worthington HV. Interventions for replacing missing teeth: antibiotics at dental implant placement to prevent complications. Cochrane Database Syst Rev. 2013 Jul 31;(7):CD004152. doi: 10.1002/14651858.CD004152.pub4. Review. — View Citation
Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci. 1998 Jun;106(3):721-64. Review. — View Citation
Flemmig TF & Newman MG. "Antimicrobials in implant dentistry." In: Newman MG, Kornman K editor. Antibiotics/antimicrobial use in dental practice. Chicago: Quintessence Publishing Co, Inc,(1990):187-200.
Freudenthaler JW, Haas R, Bantleon HP. Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. Clin Oral Implants Res. 2001 Aug;12(4):358-63. English, French, German. — View Citation
Fritz U, Ehmer A, Diedrich P. Clinical suitability of titanium microscrews for orthodontic anchorage-preliminary experiences. J Orofac Orthop. 2004 Sep;65(5):410-8. English, German. — View Citation
Gray JB, Steen ME, King GJ, Clark AE. Studies on the efficacy of implants as orthodontic anchorage. Am J Orthod. 1983 Apr;83(4):311-7. — View Citation
Heymann GC, Tulloch JF. Implantable devices as orthodontic anchorage: a review of current treatment modalities. J Esthet Restor Dent. 2006;18(2):68-79; discussion 80. Review. — View Citation
Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod. 1997 Nov;31(11):763-7. — View Citation
Lee SJ, Ahn SJ, Lee JW, Kim SH, Kim TW. Survival analysis of orthodontic mini-implants. Am J Orthod Dentofacial Orthop. 2010 Feb;137(2):194-9. doi: 10.1016/j.ajodo.2008.03.031. — View Citation
Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Takano-Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop. 2003 Oct;124(4):373-8. — View Citation
Odman J, Lekholm U, Jemt T, Brånemark PI, Thilander B. Osseointegrated titanium implants--a new approach in orthodontic treatment. Eur J Orthod. 1988 May;10(2):98-105. — View Citation
Ohmae M, Saito S, Morohashi T, Seki K, Qu H, Kanomi R, Yamasaki KI, Okano T, Yamada S, Shibasaki Y. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop. 2001 May;119(5):489-97. — View Citation
Papadopoulos MA, Tarawneh F. The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 May;103(5):e6-15. Epub 2007 Feb 21. Review. — View Citation
Prophylaxis in surgery. Veterans Administration Ad Hoc Interdisciplinary Advisory Committee on Antimicrobial Drug Usage. JAMA. 1977 Mar 7;237(10):1003-8. — View Citation
Reynders R, Ronchi L, Bipat S. Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop. 2009 May;135(5):564.e1-19; discussion 564-5. doi: 10.1016/j.ajodo.2008.09.026. Review. — View Citation
Roberts WE, Helm FR, Marshall KJ, Gongloff RK. Rigid endosseous implants for orthodontic and orthopedic anchorage. Angle Orthod. 1989 Winter;59(4):247-56. — View Citation
Roberts WE, Marshall KJ, Mozsary PG. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Angle Orthod. 1990 Summer;60(2):135-52. — View Citation
Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS. Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod. 1984 Aug;86(2):95-111. — View Citation
Sharaf B, Jandali-Rifai M, Susarla SM, Dodson TB. Do perioperative antibiotics decrease implant failure? J Oral Maxillofac Surg. 2011 Sep;69(9):2345-50. doi: 10.1016/j.joms.2011.02.095. Epub 2011 Jun 15. Review. — View Citation
Wehrbein H, Merz BR. Aspects of the use of endosseous palatal implants in orthodontic therapy. J Esthet Dent. 1998;10(6):315-24. — View Citation
* Note: There are 24 references in all — Click here to view all references
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | Mini-screw implant success or failure | Participants will undergo an intra-oral exam to determine mobility of the mini-screw(s), to check for inflammation at the site of mini-screw placement. Mobility will be determined by placing a small amount of force on the mini-screw with a cotton plier. The amount of mobility will be assessed as having no mobility (Grade 0), having between 0mm and 1 mm of mobility (Grade 1), or having more than 1 mm of mobility (Grade 2). Inflammation will be assessed as having no redness or swelling at the site (Grade 0), having redness only at the site (Grade 1), or having both redness and swelling (Grade 2). Success of the mini-screw will be defined as number of survival with "Mobility Grade 0 or 1" & "No Pain" & "Inflammation Grade 0 or 1".
Failure of the mini-screw will be immediately determined as failed if the mini-screw is not present at one of the time points or upon an assessment of Grade 2 mobility. Grade 2 mobility will result in removal of the mini-screw. |
T(0) at time of insertion | |
| Primary | Mini-screw implant success or failure | Participants will undergo an intra-oral exam to determine mobility of the mini-screw(s), to check for inflammation at the site of mini-screw placement. Mobility will be determined by placing a small amount of force on the mini-screw with a cotton plier. The amount of mobility will be assessed as having no mobility (Grade 0), having between 0mm and 1 mm of mobility (Grade 1), or having more than 1 mm of mobility (Grade 2). Inflammation will be assessed as having no redness or swelling at the site (Grade 0), having redness only at the site (Grade 1), or having both redness and swelling (Grade 2). Success of the mini-screw will be defined as number of survival with "Mobility Grade 0 or 1" & "No Pain" & "Inflammation Grade 0 or 1".
Failure of the mini-screw will be immediately determined as failed if the mini-screw is not present at one of the time points or upon an assessment of Grade 2 mobility. Grade 2 mobility will result in removal of the mini-screw. |
T(1) at 1 month post-placement | |
| Primary | Mini-screw implant success or failure | Participants will undergo an intra-oral exam to determine mobility of the mini-screw(s), to check for inflammation at the site of mini-screw placement. Mobility will be determined by placing a small amount of force on the mini-screw with a cotton plier. The amount of mobility will be assessed as having no mobility (Grade 0), having between 0mm and 1 mm of mobility (Grade 1), or having more than 1 mm of mobility (Grade 2). Inflammation will be assessed as having no redness or swelling at the site (Grade 0), having redness only at the site (Grade 1), or having both redness and swelling (Grade 2). Success of the mini-screw will be defined as number of survival with "Mobility Grade 0 or 1" & "No Pain" & "Inflammation Grade 0 or 1".
Failure of the mini-screw will be immediately determined as failed if the mini-screw is not present at one of the time points or upon an assessment of Grade 2 mobility. Grade 2 mobility will result in removal of the mini-screw. |
T(2) at 3 months post-placement | |
| Primary | Mini-screw implant success or failure | Participants will undergo an intra-oral exam to determine mobility of the mini-screw(s), to check for inflammation at the site of mini-screw placement. Mobility will be determined by placing a small amount of force on the mini-screw with a cotton plier. The amount of mobility will be assessed as having no mobility (Grade 0), having between 0mm and 1 mm of mobility (Grade 1), or having more than 1 mm of mobility (Grade 2). Inflammation will be assessed as having no redness or swelling at the site (Grade 0), having redness only at the site (Grade 1), or having both redness and swelling (Grade 2). Success of the mini-screw will be defined as number of survival with "Mobility Grade 0 or 1" & "No Pain" & "Inflammation Grade 0 or 1".
Failure of the mini-screw will be immediately determined as failed if the mini-screw is not present at one of the time points or upon an assessment of Grade 2 mobility. Grade 2 mobility will result in removal of the mini-screw. |
T(3) at 6 months post-placement |