Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03545737
Other study ID # 98776
Secondary ID
Status Completed
Phase
First received
Last updated
Start date June 15, 2018
Est. completion date December 13, 2018

Study information

Verified date February 2023
Source The First Hospital of Qinhuangdao
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

One-lung ventilation (OLV) is required for the most of thoracic surgery to facilitate surgical visualization by collapsing the lung. The double-lumen tube (DLT) is the commonly used device for OLV. The objective of this study was to compare the accuracy of the distances between vocal cords to carina of trachea and formula base on patient's height as a guide for the intubation of a Left-sided Double-lumen tube


Description:

In previous study, investigators found that the distances between vocal cords to carina of trachea was a useful predictive method for the intubation of a Left-sided Double-lumen tube. However in some hospitals preoperative chest CT scans not contain the vocal cords slice. So in this study investigators will compare the accuracy of the distances between the midpoint of the thyroid cartilage to suprasternal notch base on body surface measurement add the distance between suprasternal notch to carina of trachea according to chest CT and formula base on patient's height as a guide for the intubation of a Left-sided Double-lumen tube.


Recruitment information / eligibility

Status Completed
Enrollment 60
Est. completion date December 13, 2018
Est. primary completion date November 21, 2018
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years to 70 Years
Eligibility Inclusion Criteria: 1. Adult patients undergoing elective left side thoracic surgery 2. Requiring a Uniblocker or DLT for one-lung ventilation

Study Design


Related Conditions & MeSH terms

  • Therapeutic Procedural Complication

Intervention

Other:
Measurement
The distances between the midpoint of the thyroid cartilage to suprasternal notch base on body surface measurement add the distance between suprasternal notch to carina of trachea according to chest CT
Formula
The formula base on patient's height as a guide for the intubation of a Left-sided Double-lumen tube

Locations

Country Name City State
China ?? Qinhuangdao Hebei

Sponsors (1)

Lead Sponsor Collaborator
The First Hospital of Qinhuangdao

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Primary The incidence of the injuries of bronchi and carina The degree of bronchi and carina injuries: 1 clear; 2 a few petechiae; 3coalesced petechiae, hemorrhage, or ecchymosis; 4 erosion 1-3days
Secondary The incidence of dislodgement The incidence of dislodgement after repositioning 1 day
Secondary The intubation time The intubation time (IT) was defined as the time from the anesthesiologist inserted the video laryngoscope between the teeth of patients until the double lumen-tube at the optimal position checked by Fiberoptic bronchoscopy 1-5min
See also
  Status Clinical Trial Phase
Completed NCT02943928 - Placement of the Double-Lumen Tube Without Fiberoptic Bronchoscope Assistance N/A
Completed NCT02922270 - Outcome and Risk Factors For Mortality in Peritoneal Dialysis Patients: 20 Years Experience in a Single Turkish Center N/A
Completed NCT04127903 - The Length of the Right Main Stem Bronchus as a Guide to Right-sided Double-lumen Tube Use N/A
Completed NCT02792855 - Comparing the "sniffing Position" , "Simple Head Extension" and "Neutral Position" N/A
Completed NCT02816918 - Extraluminal Use of the Bronchial Blocker of Univent Tube Phase 1
Completed NCT02669550 - Comparison of Disposcope Endoscope and Fiberoptic Bronchoscope N/A
Recruiting NCT03392818 - An Innovative Approach for Uniblocker Intubation N/A
Completed NCT03392922 - A Comparison the Intubation of a Left Sided Double Lumen Tube and Uniblocker N/A
Completed NCT03008473 - Chest CT for the Placement of the Uniblocker N/A
Completed NCT05739318 - the Diameter of Double-lumen Tube Measured by Different Methods N/A
Completed NCT05331287 - Comparing the "Snifing Position" , "Simple Head Extension" and "Neutral Position" N/A