Therapeutic Procedural Complication Clinical Trial
Official title:
A Comparison of Disposcope Endoscope and Fiberoptic Bronchoscope During Awake Orotracheal Intubation in Obese Patients With Anticipated Difficult Airway : A Prospective, Randomised and Controlled Clinical Trial
The fiberoptic bronchoscope (FOB) has been the preferred instrument for many years in the management of difficult tracheal intubation, and it is considered as a gold standard. The disposcope endoscope (DE) is a medical device for endotracheal intubation used in clinical practice recently.This study compares FOB and DE for awake orotracheal intubation in obese patients with anticipated difficult airway.
Forty obese patients with anticipated difficult airways were randomised to undergo awake orotracheal intubation by FOB(group F) or DE(group D) after conscious sedation. The conditions of orotracheal intubation, the time needed to view the vocal cords and to complete the orotracheal intubation, the hemodynamic changes and the adverse events including bradycardia, respiratory depression during orotracheal intubation, throat pain, hoarseness and memory after surgery were recorded. The ease of view the vocal cords and passing the tracheal tube through the glottis were also evaluated by using a visual analogue scale (VAS) by operator. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02943928 -
Placement of the Double-Lumen Tube Without Fiberoptic Bronchoscope Assistance
|
N/A | |
Completed |
NCT02922270 -
Outcome and Risk Factors For Mortality in Peritoneal Dialysis Patients: 20 Years Experience in a Single Turkish Center
|
N/A | |
Completed |
NCT04127903 -
The Length of the Right Main Stem Bronchus as a Guide to Right-sided Double-lumen Tube Use
|
N/A | |
Completed |
NCT03545737 -
Compare a New Method and Formula as a Guide for the Intubation of a Left-sided Double-lumen Tube
|
||
Completed |
NCT02792855 -
Comparing the "sniffing Position" , "Simple Head Extension" and "Neutral Position"
|
N/A | |
Completed |
NCT02816918 -
Extraluminal Use of the Bronchial Blocker of Univent Tube
|
Phase 1 | |
Recruiting |
NCT03392818 -
An Innovative Approach for Uniblocker Intubation
|
N/A | |
Completed |
NCT03392922 -
A Comparison the Intubation of a Left Sided Double Lumen Tube and Uniblocker
|
N/A | |
Completed |
NCT03008473 -
Chest CT for the Placement of the Uniblocker
|
N/A | |
Not yet recruiting |
NCT05739318 -
the Diameter of Double-lumen Tube Measured by Different Methods
|
N/A | |
Completed |
NCT05331287 -
Comparing the "Snifing Position" , "Simple Head Extension" and "Neutral Position"
|
N/A |