View clinical trials related to Osteoarthritis, Knee.
Filter by:Crepitus causing unsatisfied result to patients after posterior stabilized total knee arthroplasty. Recent retrospective study demonstrated removal of hyperplastic synovium in distal quadriceps caused reduce of crepitus. However, this study has limitation of time gap exist between arms, different in observation time and bias caused by retrospective review. Thus aim of this study is that by randomized trial, verified hyperplastic synovium in distal quadriceps causing crepitus. Target enrolled patients in this study are scheduled to perform both total knee arthroplasty. Experimental group is randomized side (right or left) of knee, and control group is other side of knee. Both arms decided by randomized number table. Crepitus measured after 3mo, 6mo, 1year after surgical treatment
The goal of this randomized, double blind, placebo-controlled clinical trial is to learn about, the effect of metformin compared with placebo-controlled group on disease activity and interleukin-6 level in patients with knee osteoarthritis.The main question it aims to answer is:Is Metformin as add-on therapy more effective in reducing disease activity in Ibuprofen-treated patients with grade II-III knee osteoarthritis? Half of Participants will receive metformin with standard of care(ibuprofen and rabeprazole) while other half placebo and standard of care (ibuprofen and rabeprazole).
Total knee arthroplasty (TKA) is the most common surgery in North America and the second most common in Europe. One of the most critical issues for stability and durability of the interventional is the prosthesis-bone geometric fit, where a required a perfect match; the recent availability of custom 3D implants can overcome this problem. In order to further improve a TKA surgery, it is in fact, it is possible today to completely customize the procedure for each individual patient, with cost and time now accessible. This intervention can be performed with the use of instrumentation specific to the patient (so-called resin 'cutting templates' referred to as PSI, "Patient Specific Instrumentation") to make cuts accurate bone cuts in accordance with a specific 3D preoperative plan . Also the design and fabrication in of the components prosthetic components themselves, in metal and polyethylene, is done by means of 3D printing. Based on the unique anatomy of each patient, the precise sagittal orientation and axial rotation of the components of the prosthesis customized for the surgeon, it is possible to plan and perform the surgery quickly and in accordance with the exact specifications of the individual patient. These procedures should also make it possible to greatly reduce the instrumentation and the sizes that need to be available in the operating room, reducing time and costs associated with transportation and storage . The objective of this study is to compare primary TKAs performed with a customized procedure (prostheses customized for each patient based on his or her reconstructed knee morphology by tomographic scans, and implanted via cutting guides customized for the patient) with standard primary TKAs, considering: the objective radiological results, the subjective results of the patients and the costs of both procedures.
This research assesses the effects that Photobiomodulation Therapy (PBMT) has on Intra-articular administered Plasma-Rich Platelet (PRP) injections for Knee Osteoarthritis (KOA) treatment through evaluations of synovial and serum inflammatory and reparative biomarkers. A comparison of Physical Therapy (PT) vs PT + PRP vs PT + PBMT vs PT + PRP + PBMT for KOA treatment is made. The relationship between self-reported pain and functionality and treatment mechanisms is analyzed along with an analysis of the intersectionality between participant self-reported pain and functionality and medicine markers across treatment groups. These aims seek to inform current treatment practices in treating KOA and returning Active-Duty Service Members to duty readiness.
The goal of this clinical trial is to examine the effect of a single autologous, intra-articular injection of MFat versus saline injection for the treatment of pain and function associated with K/L grade 2/3 knee Osteoarthritis. Participants will receive an injection of MFat or saline.
Knee Osteoarthritis is a chronic degenerative joint disease with complex etiology that results in loss of normal joint function due to damage to the articular cartilage. It is characterized by pain, swelling, inflammation and narrowing in articular cartilage. Hip muscle weakness has been observed in persons with knee OA and poor core stability may be one of the other contributing factors that lead to knee OA development as well as its progression. Core stabilization and muscular synergism of the trunk and hip work is an effective way to improve lower limb strength balance and prevent injury. So the lumbopelvic stability is vital to support loads on the knee joint.
Prospective evaluation of the safety and effectiveness of the MISHA Knee System. The study will collect data on the procedural and long-term adverse events, WOMAC pain and function scores, KSS satisfaction, subsequent surgical interventions, BMI levels, range of motion, UCLA activity level of the subjects, and perform radiographic/x-ray evaluations at clinical visits through 5 years post-procedure. The primary analysis of this study is freedom from device- and procedure-related SSIs at five (5) years post-implantation. This study will also assess device performance in subjects with intact and retained devices and subjects with devices removed prior to study termination and freedom from conversion to arthroplasty through 5 years. Study subjects will be followed over a five-year post-implant period.
The purpose of this study is to evaluate the effect of one single intra-articular (IA) injection of HYALUBRIX 60® plus physical exercise program (PEP) in terms of pain reduction, compared to PEP alone, in patients with knee osteoarthritis (OA).
The aim is to demonstrate that preoperative exercises (prehabilitation) using blood-flow restriction training (BFRT) is safe, well tolerated, improves muscle function, decreases functional limitation, and increases physical activity in older adults awaiting total knee replacement (TKR).
The purpose of this study was to analyze and study the efficacy and safety of autologous adipose-derived vascular matrix components (SVF) in patients with knee osteoarthritis before and after treatment through clinical evaluation, radiation index, and metabolic index comparison between plasma and irrigation solution before and after SVF injection.