Clinical Trials Logo

Clinical Trial Summary

For the first time in Russia, it is planned to introduce and study primary knee arthroplasty using an active robotic system. The aim is to increase the efficiency of primary total knee arthroplasty using an active robotic surgical system. Traditional endoprosthetics of the knee joint (TKA) has now reached its maximum manufacturability and efficiency, but the accuracy of the performance depends on the skill and experience of the surgeon, as well as the efficiency of the cutting instrument (oscillator saw) when performing bone resection, the condition of the instrument and on the density of bone tissue fabric, which is highly variable. Modern RSS used in orthopedics include a robotic arm, robotic cutting devices with a computer navigation system, which are in active, semi-automatic or passive control mode. The main advantage of robotic systems is accurate preliminary planning using 3D modeling, use individual implant selection and virtual positioning.The active robotic surgical system TSolution-One allows participants to level the error in the positioning of the implant. The active robotic surgical system (ARSS) allows to correctly install the implant, which affects its service life, reduces the risks of postoperative complications, quickly returns to the usual way of life and forgets about the technical negative sensations and limitations that existed before the operation.It is planned to conduct an open-label retrospective and prospective clinical study in parallel observations.The study is planned to include 300 patients with osteoarthritis of the knee joint stage 3-4 (according to Kellgren-Lawrence). Investigators took three groups of patients, 100 patients each, and offered different options for total knee arthroplasty techniques.According to the research:-A clinical active robotic system for primary total knee arthroplasty will be introduced in Russia-There will be recommended indications and contraindications for this system in patients with gonarthrosis-The methodology of preoperative planning will be improved-The results of primary knee arthroplasty with an active robotic system will be evaluated in comparison with standard techniques and computer navigation-The methodology developed and improved in the dissertation will be introduced into the work of the clinical departments of traumatology, orthopedics and disaster surgery, studying the learning curve.


Clinical Trial Description

Relevance: Robotic technologies were first introduced into medicine in the 1950s. The use of robotic systems in surgery begins with the use in neurosurgery. In 1985, the Programmable Universal Manipulation Arm (PUMA) 560 was introduced to perform CT-guided brain biopsy. In 1992, the Robodoc system (IBM) became the first orthopedic robotic system used in orthopedics for hip replacement, which subsequently improved the ability to automatically perform the stages of prosthetics. (Caspar system, Acrobot). Around the same time, the development of a robot for performing total knee arthroplasty began. A distinctive feature of total knee arthroplasty (TKA) is the manufacturability of the stages and the high accuracy of surgical manipulations, which attracts the attention of many robotic surgical systems (RSS). Traditional total knee arthroplasty (TKA) has now reached its maximum manufacturability and efficiency, but the accuracy of the performance depends on the skill and experience of the surgeon, as well as the accuracy of the cutting instrument (oscillator saw) when performing bone resection, the condition of the instrument and the density of the bone fabric, which is highly variable. The use of intramedullary guides during conventional surgery increases the risk of thromboembolic and cardiorespiratory complications. Computer navigation partially solves the problem of resection accuracy, infrared cameras read information from sensors and display a model with anatomical and kinematic features of the knee joint, which helps the surgeon to more accurately determine the level and direction of resection, but cannot ensure the accuracy of this manipulation and compliance with the preoperative plan. Modern RSS used in orthopedics include a robotic arm, robotic cutting devices with a computer navigation system that operate in an active, semi-automatic, or passive control mode. The main advantage of robotic systems is accurate preoperative planning using 3D modeling, the possibility of individual selection of the implant and virtual positioning. Another advantage is the ability to accurately reproduce the preoperative plan during orthopedic surgery. Today, active robotic surgical systems (ARSS) are used in clinical practice. ROBODOC / TSolution One. Robotic Surgical System (Curexo Technology, Fremont, Calif.), And Navio PFS (Blue Belt Technologies, Plymouth, Minnesota) Semi-Active Surgical Systems, OMNI Robotic System (OMNIlife Science, East Taunton, MA), RIO Robotic Arm Interactive Orthopedic System (Mako Surgical Corporation, Fort Lauderdale, Florida), ROSA Knee (Zimmer Zimmer Biomet, Montreal (Quebec), Canada). The active robotic surgical system TSolution-One allows participants to level the error in the positioning of the implant. The accuracy of the filing is not affected by the manual skills of the surgeon, and does not depend on the density of bone tissue. Significant advantages of the system are: 1) precise preoperative breading; 2) rigid fixation of the limb, hip and tibia displacement sensors; 3) active autonomous milling without the participation of a surgeon; 4) accuracy of resection according to the preoperative plan; 5) rotation of the tibial component as in the preoperative plan; 6) no manual tools required; 7) postoperative control of the results of the operation. The active robotic surgical system (ARSS) allows participants to correctly install the implant, which affects its service life, reduces the risks of postoperative complications, the patient quickly returns to his usual way of life and forgets about those negative feelings and limitations that were before the operation. The novelty of the proposed topic: For the first time in Russia, it is planned to introduce and study total knee arthroplasty using an active robotic system. Apply the use of a 3D patient model and the creation of an individual personalized preoperative plan using a robotic system for knee arthroplasty. Aim and objectives of the research: aim: To increase the efficiency of primary total knee arthroplasty using an active robotic surgical system. objectives: 1. To study the possibilities of an active robotic system for primary arthroplasty of the knee joint, to determine indications and contraindications for use in endoprosthetics of the knee joint in patients with primary arthrosis. 2. To evaluate the technique of preoperative planning for total knee arthroplasty using an active robotic system in patients with arthrosis. 3. To work out the technique of total knee arthroplasty using an active robotic system, compare with computer navigation and the traditional method. 4. To evaluate the results of total knee arthroplasty using an active robotic system in comparison with the use of standard techniques and computer navigation. 5. Examine complications 6. Determine the place of the active robotic surgical unit in the total knee arthroplasty system. Type of new research: an open-label, retrospective and prospective observational clinical study in parallel groups. Research object and number of observations: the study is planned to include 300 patients with osteoarthritis of the knee joint of stage 3-4 (according to Kellgren-Lawrence). Methods of the research: 1. General clinical examination of patients (collection of complaints, examination, assessment of physical findings and local status); 2. Assessment of the range of motion in the knee joint before and after surgery; 3. Performing X-ray images and CT of the knee joint before and after surgery, with the determination of the angles: LDFA, MPTA, Q, MAD; 4. Preoperative 3D planning on the TPLAN workstation; 5. Surgical treatment. 1) Primary total knee arthroplasty using the active robotic surgical system TSolution One, TCAT 2) Primary total knee arthroplasty using computer navigation 3) Primary total knee arthroplasty using the standard recommended set of instruments. 6. Evaluation of patient treatment results according to scales: VAS, KSS, OKS, WOMAC, SF-36, ASA, FJS-12, Spielberger test. 7. Methods of statistical processing of the material: statistical processing of data is planned to be carried out on a personal computer using Excel software packages and using standard methods of variation statistics using SPSS 16 statistical software packages. Estimated research result: 1. For the first time in Russia, an active robotic system for primary total knee arthroplasty will be introduced into clinical practice. 2. Indications and contraindications for the use of this system in patients with gonarthrosis will be determined. 3. The methodology of preoperative planning will be improved. 4. The results of primary total knee arthroplasty using an active robotic system will be evaluated in comparison with the use of standard techniques and computer navigation. 5. The methodology developed and improved in the dissertation will be introduced into the work of the clinical bases of the Department of Traumatology, Orthopedics and Disaster Surgery, the study of the learning curve. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04667390
Study type Interventional
Source I.M. Sechenov First Moscow State Medical University
Contact
Status Active, not recruiting
Phase N/A
Start date September 1, 2018
Completion date August 2025

See also
  Status Clinical Trial Phase
Recruiting NCT04651673 - Prescribed Knee Brace Treatments for Osteoarthritis of the Knee (Knee OA)
Completed NCT05677399 - Knee Osteoarthritis Treatment With Peloidotherapy and Aquatic Exercise. N/A
Active, not recruiting NCT04043819 - Evaluation of Safety and Exploratory Efficacy of an Autologous Adipose-derived Cell Therapy Product for Treatment of Single Knee Osteoarthritis Phase 1
Recruiting NCT06000410 - A Study to Evaluate the Efficacy of Amniotic Suspension Allograft in Patients With Osteoarthritis of the Knee Phase 3
Completed NCT05014542 - Needling Techniques for Knee Osteoarthritis N/A
Recruiting NCT05892133 - Prehabilitation Effect on Function and Patient Satisfaction Following Total Knee Arthroplasty N/A
Recruiting NCT05528965 - Parallel Versus Perpendicular Technique for Genicular Radiofrequency N/A
Active, not recruiting NCT03472300 - Prevalence of Self-disclosed Knee Trouble and Use of Treatments Among Elderly Individuals
Active, not recruiting NCT02003976 - A Randomized Trial Comparing High Tibial Osteotomy Plus Non-Surgical Treatment and Non-Surgical Treatment Alone N/A
Active, not recruiting NCT04017533 - Stability of Uncemented Medially Stabilized TKA N/A
Completed NCT04779164 - The Relation Between Abdominal Obesity, Type 2 Diabetes Mellitus and Knee Osteoarthritis N/A
Recruiting NCT04006314 - Platelet Rich Plasma and Neural Prolotherapy Injections in Treating Knee Osteoarthritis N/A
Recruiting NCT05423587 - Genicular Artery Embolisation for Knee Osteoarthritis II N/A
Enrolling by invitation NCT04145401 - Post Market Clinical Follow-Up Study- EVOLUTION® Revision CCK
Active, not recruiting NCT03781843 - Effects of Genicular Nerve Block in Knee Osteoarthritis N/A
Completed NCT05974501 - Pre vs Post Block in Total Knee Arthroplasty (TKA) Phase 4
Completed NCT05324163 - Evaluate Efficacy and Safety of X0002 in Treatment of Knee Osteoarthritis Phase 3
Completed NCT05529914 - Effects of Myofascial Release and Neuromuscular Training for Pes Anserine Syndrome Associated With Knee Osteoarthritis N/A
Recruiting NCT05693493 - Can Proprioceptive Knee Brace Improve Functional Outcome Following TKA? N/A
Not yet recruiting NCT05510648 - Evaluation of the Effect of High-intensity Laser Therapy in Knee Osteoarthritis N/A