View clinical trials related to Heart Valve Disease.
Filter by:This is a prospective, multi-center, randomized effectiveness trial of the CardioGard Embolic Protection Cannula in high-risk valve surgery patients.
The purpose of this study is to assess the safety and performance of the Trialign System for the treatment of symptomatic chronic functional tricuspid regurgitation (FTR) in patients with a minimum of moderate tricuspid regurgitation. The procedure will be performed with the PTVAS device using a non-surgical percutaneous approach to tricuspid valve repair in patients who have FTR with a minimum of moderate tricuspid regurgitation.
Patients undergoing Open Cardiac Surgery will be randomized into two groups. Group I will be ventilated with 40% Fio2 during induction, surgery and in Postoperative care unit. Group II will be ventilated with 100% Fio2 during induction and with 60-70% ( determined according to the arterial blood gas sample results) during surgery and in Postoperative care unit. Hemodynamic parameters ( systolic arterial pressure, diastolic arterial pressure, heart rate ), Arterial blood gas samples ( PaO2, PaCO2, pH, Oxygen saturation, Lactate), and pre and post cardiopulmonary bypass Superoxide dismutase and malonyl aldehyde levels.
To value the accuracy of the dosing algorithm published by the International Warfarin Pharmacogenetics Consortium in Chinese patients after heart valve replacement. To value the accuracy of warfarin pharmacogenomics algorithm by the algorithm calculated dose and actual dose in the Chinese patients.
Aortic stenosis (AS) is the most common valve disease among the adult population, in the majority of the cases it only requires treatment in advanced age. Transcatheter aortic valve implantation (TAVI) has become available as an alternative treatment for very high risk or even inoperative patients who are suffering from symptomatic aortic stenosis. Until now it has been learnt that there are group of patients who are in a very bad condition and who are so frail that they do not benefit from TAVI. These patients have worse survival rate and more importantly poor quality of life in spite of a successful procedure. Cardiac surgery risk scores like Society of Thoracic surgery score (STS) and EUROSCORE are less accurate in aging high risk people. In elderly it is principal to make differentiation between utility and futility. On the other hand, beside frailty status the main barrier to TAVI is the risk of neurological impairment. Neurological injury and impairment in TAVI can occur as cerebrovascular event (CVE) and/or neurocognitive dysfunction. The two neurocognitive dysfunctions - post-operative delirium (POD) and post-operative cognitive dysfunction (POCD). Most cases remain undetected although clinically could be apparent or silent. The neurological injury can be observed and/or detected by neuroimaging techniques and cognitive trajectories. A well established and validated frailty score based on relatively simple and feasible tests could help in our everyday practice to evaluate the prognosis of elderly people undergoing TAVI and to determine those patients who really benefit from the procedure.
The purpose of this study is to assess the early safety and performance of the Mitralign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS) for the treatment of symptomatic chronic functional tricuspid regurgitation (FTR). The procedure will be performed with the PTVAS device using a non-surgical percutaneous approach to tricuspid valve repair in patients who have FTR with a minimum of moderate tricuspid regurgitation.
The purpose of the study is to generate early US feasibility data of the CardiAQ™ Transcatheter Mitral Valve Implant System. The study will enroll patients with moderate to severe mitral valve regurgitation who are considered high risk for mortality and morbidity from conventional open-heart surgery.
The purpose of the study is to evaluate the initial short and long-term safety and performance of the CardiAQ™ Transcatheter Mitral Valve Implantation System using the Transapical Delivery System. The study will enroll patients with moderate to severe mitral valve regurgitation who are considered high or extreme risk for mortality and morbidity from conventional open heart surgery.
1. Title: Clinical study of the relationship between Pharmacogenomics and warfarin dose in Chinese patients 2. Drug: Warfarin 3. Design: To value the accuracy of warfarin Pharmacogenomics algorithm by the algorithm calculated dose and actual dose in the Chinese patients. 4. Hypothesis:Pharmacogenomic algorithm guided dose can help to predict warfarin dose in Chinese patients.
Statins have been used to low cholesterol to prevent and treat coronary artery diseases. It was also reported that statins could protect endothelial function and cardiac function during coronary artery bypass graft. The investigators recent found simvastatin reduced myocardial injury during noncoronary artery cardiac surgery in single medical center. The investigators further investigate that whether simvastatin can protect myocardium during noncoronary artery cardiac surgery with cardiopulmonary bypass and improve cardiac function with long term use postoperatively in two medical centers.