Hallux Valgus Clinical Trial
Official title:
The Performance and Safety Evaluation of Bioabsorbable Headless Inion CompressOn Screws in Selected Fracture, Osteotomy and Artrodesis Surgeries of the Foot and Ankle
The study in question is a post market clinical follow up (PMCF) study to evaluate the safety and performance of bioabsorbable headless compression screw Inion CompressOn in selected fracture, osteotomy and arthrodeses operations of the foot and ankle. The study recruits 125 adult patients who meet the acceptance criteria. The follow-up time for each study patient is 4 years. The study is a single center single group study which is conducted in Tampere University Hospital (TAYS) in Finland. The main focus of the study in terms of performance is to evaluate the bone healing/ossification of operated areas. The main focus of the study in terms of safety is to evaluate the occurrence of adverse events and required revision surgeries that are or might be related to the study device.
The study in question is a post market clinical follow-up study to evaluate the safety and performance of bioabsorbable headless compression screw Inion CompressOn in selected fracture, osteotomy and arthrodeses operations of the foot and ankle. The main focus of the study in terms of performance is to evaluate the bone healing/ossification of operated areas. The main focus of the study in terms of safety is to evaluate the occurrence of adverse events and required revision surgeries that are or might be related to the study device. The Inion CompressOn™ screws are cannulated headless compression screws made of degradable co-polymers composed of L-lactic acid and D-lactic acid. These polymers have a long history of safe medical use and they degrade in vivo by hydrolysis into alpha-hydroxy acids that are metabolised by the body. The screws retain their initial strength up to 12 weeks after implantation and gradually lose their strength thereafter. Bioabsorption takes place within two to four years. The Inion CompressOn™ products are intended for maintenance of alignment and fixation of bone fractures, comminuted fractures, osteotomies, arthrodeses or bone grafts (i.e., autografts or allografts) in the presence of appropriate additional immobilization (e.g., rigid fixation implants, cast or brace). In the field of foot and ankle traumatology the surgical indications of this study include medial malleolar fractures, Lisfranc injuries, talus fractures, calcaneal fractures and navicular bone fractures. In the field of foot and ankle orthopaedics the surgical indications of the study include arthrodesis of the talonavicular joint, calcaneacuboideal joint, tarsometatarsal joint and first metatarsophalangeal (MTP1) joint, and osteotomies of the first metatarsal bone, second metatarsal bone (weil) and calcaneal bone. The clinical data collection acquired from this study is a requirement of the EU Notified Body as part of the admitted CE mark certification, in cases when the device is initially approved based on the clinical data of an equivalent device. In this case, the equivalent device has been Inion FreedomScrew, which is made of the same material composition and has the same indications for use. Inion CompressOn Screw has new design features such as headless design, and threading which allows compression to the fracture line. Also new sizes are introduced. The study recruits 125 adult patients who meet the acceptance criteria and have signed the informed consent. The follow-up time for each study patient is 4 years. Each patient has 6 follow-up time points related to the study. These time points consist of: 1. screening visit (-180-0 days before operation), 2. operation (day 0), 3. post-operative follow-up 1 (6 weeks after operation +/- 1 week), 4. post-operative follow-up 2 (3 months after operation +/- 2 weeks), 5. post-operative follow-up 3 (2 years after operation +/- 2 months) 6. post-operative follow-up 4 (4 years after operation +/- 4 months) The first 4 time points are within standard care, the last 2 time points (post-operative follow-up 3 and post-operative follow-up 4) are scheduled for study purposes only to be able to gain performance and safety data based on adequate follow-up time. The study is a single center single group study which is conducted in Tampere University Hospital (TAYS) in Finland. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT04473196 -
The Effect of Weight Bearing on Patient Outcomes Following 1st MTP Joint Fusion
|
N/A | |
Recruiting |
NCT05587569 -
Outcomes Following Combined Adductoplasty™ and Lapiplasty® (MTA3D)
|
N/A | |
Completed |
NCT02121119 -
Lidocaine Versus Bupivacaine in Ambulatory Continuous Block With Elastomeric Pump
|
Phase 4 | |
Enrolling by invitation |
NCT00600899 -
Home Infusors for Analgesia After Foot Surgery
|
Phase 4 | |
Completed |
NCT05579054 -
Translation, Validity, and Reliability of the Foot Posture Index (FPI-6) - Turkish Version
|
||
Terminated |
NCT05082012 -
Early Weight-Bearing After the Lapiplasty Mini-Incision Procedure (Mini3D)
|
N/A | |
Recruiting |
NCT05051709 -
Can Hypermobility of First Ray Affect Surgical Treatment of Hallux Valgus
|
N/A | |
Recruiting |
NCT04716140 -
Prospective Study: The Effect on Clinical Outcome After Treatment of MTP Cartilage Lesions in Hallux Valgus Surgery
|
N/A | |
Active, not recruiting |
NCT04145882 -
Efficacy of Additional Osteotomies to Correct Hallux Valgus
|
N/A | |
Completed |
NCT04468555 -
Hallux Valgus Manual Therapy Based on Global Postural Reeducation.
|
N/A | |
Terminated |
NCT03257540 -
Early Weight-Bearing After Lapidus Arthrodesis
|
||
Completed |
NCT03846687 -
Validation of Patient Reported Outcome Measures for Use in Hallux Valgus
|
||
Completed |
NCT04365712 -
Osteotomy of the 1st Metatarsal for Hallux Valgus Using Pneumatic Oscillating Saw or Piezoelectric Scalpel
|
N/A | |
Recruiting |
NCT02282956 -
Ultrasound Guided Single Shot Block of Posterior Tibial Nerve for Postoperative Pain Relief After Hallux Valgus Surgery
|
Phase 4 | |
Withdrawn |
NCT01555216 -
Continuous Tibial Nerve Block Versus Single Shot Tibial Nerve Block
|
N/A | |
Completed |
NCT00683137 -
Analgesic Efficacy And Safety of Valdecoxib For Treatment Of Post-Surgical Pain From Bunionectomy Surgery
|
Phase 3 | |
Terminated |
NCT04103814 -
Effect of Topical CBD Cream for Degenerative Hallux Disorders
|
Phase 2/Phase 3 | |
Completed |
NCT03423498 -
The Toe-spread-out Exercise in Patients With Hallux Valgus and Without the Deformity
|
N/A | |
Not yet recruiting |
NCT06076655 -
Hallux Valgus Treatment Developed for Children With Cerebral Palsy
|
N/A | |
Recruiting |
NCT02915822 -
COSMIC Study - Comparing Open Scarf/Akin Osteotomy and Minimally Invasive Chevron/Akin. A Feasibility Study
|
N/A |