Clinical Trials Logo

Clinical Trial Details — Status: Withdrawn

Administrative data

NCT number NCT03827434
Other study ID # HP-00084458
Secondary ID
Status Withdrawn
Phase N/A
First received
Last updated
Start date December 1, 2018
Est. completion date October 31, 2019

Study information

Verified date September 2023
Source University of Maryland, Baltimore
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The prevalence of Diabetes Mellitus (DM) is rising and more than 30 million of Americans or 9.4% of the US population has DM. Several large scale randomized clinical trials have found that improved glycemic control reduces the development of complications in patients with DM. However intensive glucose management carries an increased risk of hypoglycemia, a condition that may lead to neurological damage and is associated with increased incidence of cardiovascular events and mortality. Reducing uncontrolled hyperglycemia and hypoglycemia represents therefore an important objective, as may decrease the direct and indirect impact that diabetes has in our health care system. Achieving optimal glycemic control requires frequent blood glucose monitoring by the patients and recurrent clinic visits,which is often difficult to achieve, as access to typical DM clinic is at least sub optimal. m-Health and telemedicine health solutions represent alternative ways to manage patients in the outpatient setting and have been applied in different medical areas, among them in diabetes. However, almost all the telemedicine studies that have been previously performed and recruited DM patients used telemedicine solutions which were based on point of care (POC) finger-stick glucose testing, which are checked infrequently , usually 4-6 times/day. Continuous glucose monitoring (CGM) devices offer additional ways to monitor blood glucose values and can provide numerous glucose measurements (as frequent as every 5 min). By using software applications, such as the Clarity (Dexcom), which highlights glucose patterns, trends and statistics in standardized reports, providers can make safe recommendations of adjusting DM medications, especially insulin titration. In this randomized clinical trial investigators propose to use CGM devices and Clarity software as a telemedicine platform in order to improve glycemic control and improve health outcomes.


Recruitment information / eligibility

Status Withdrawn
Enrollment 0
Est. completion date October 31, 2019
Est. primary completion date October 31, 2019
Accepts healthy volunteers No
Gender All
Age group 21 Years and older
Eligibility Inclusion Criteria: - History of Diabetes Mellitus type 2 (DM2) on insulin - Uncontrolled glycemic control [hyperglycemia defined as Hba1c=9% in the last 3 months or clinically important hypoglycemia (any reported glucose values less than 54 mg/dl) or severe hypoglycemia (low glucose value that led to a severe event characterized by altered mental status and or physical status requiring assistance)] Exclusion Criteria: - Subjects that have a history of type 1 DM - History of type 2 DM, not treated or required to be treated with basal/bolus insulin (i.e diet only, any combination of non insulin antidiabetic drugs only, basal only insulin or bolus/short acting only insulin, or pre-mixed insulins) as these patients are less likely to benefit from CGM use. - Pregnant patients - Use of Clarity/ Share or follow applications as telehealth/telemedicine to improve DM management during the last 3 months prior to study entry. - Extensive skin changes/disease or allergies that preclude wearing the CGM sensor - Significant psychiatric illness or any mental condition rendering the subject incapable of understanding the objectives and potential consequences of the study. - Subjects without personal computer and internet network access.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Continuous glucose Monitoring Devices and Clarity Software
Patients with DM2 at the intervention group will be managed by Continuous glucose Monitoring and Clarity software
Other:
Point of Care (POC) blood glucose
Testing Blood Glucose levels with Point of Care (POC) blood glucose

Locations

Country Name City State
United States Baltimore VA Medical Center Baltimore Maryland

Sponsors (2)

Lead Sponsor Collaborator
University of Maryland, Baltimore Baltimore VA Medical Center

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Change in Hemoglobin A1c (HbA1c) among participants who are managed with Continuous Glucose Monitoring Devices and Clarity versus participants who are managed with Point of Care glucose testing (standard of care) Through study completion, 6 months after randomization
Primary Change in the number of hypoglycemic episodes among participants who are managed with Continuous Glucose Monitoring Devices and Clarity versus participants who are managed with Point of Care glucose testing (standard of care) Through study completion, 6 months after randomization
Primary Change in the number of hospitalizations among participants who are managed with Continuous Glucose Monitoring Devices and Clarity versus participants who are managed with Point of Care glucose testing (standard of care) Through study completion, 6 months after randomization
Primary Change in the number of ED visits among participants who are managed with Continuous Glucose Monitoring Devices and Clarity versus participants who are managed with Point of Care glucose testing (standard of care) Through study completion, 6 months after randomization
Primary Change in mortality among participants who are managed with Continuous Glucose Monitoring Devices and Clarity versus participants who are managed with Point of Care glucose testing (standard of care) Through study completion, 6 months after randomization
See also
  Status Clinical Trial Phase
Completed NCT03743779 - Mastering Diabetes Pilot Study
Completed NCT03786978 - Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus N/A
Completed NCT01804803 - DIgital Assisted MONitoring for DiabeteS - I N/A
Completed NCT05039970 - A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program N/A
Completed NCT04507867 - Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III N/A
Completed NCT04068272 - Safety of Bosentan in Type II Diabetic Patients Phase 1
Completed NCT03243383 - Readmission Prevention Pilot Trial in Diabetes Patients N/A
Completed NCT03730480 - User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS) N/A
Recruiting NCT02690467 - Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm. N/A
Completed NCT02229383 - Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus Phase 3
Completed NCT06181721 - Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes N/A
Completed NCT05799976 - Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure N/A
Recruiting NCT04489043 - Exercise, Prediabetes and Diabetes After Renal Transplantation. N/A
Withdrawn NCT03319784 - Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients Phase 4
Completed NCT03542084 - Endocrinology Auto-Triggered e-Consults N/A
Completed NCT02229396 - Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo Phase 3
Recruiting NCT05544266 - Rare and Atypical Diabetes Network
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Completed NCT05031000 - Blood Glucose Monitoring Systems: Discounter Versus Brand N/A
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A