Clinical Trials Logo

Clinical Trial Summary

The introduction of drug-eluting stents (DES) in the treatment of coronary artery disease has led to a significant reduction in morbidity. However, the first generation of these devices had no positive impact on the mortality after PCI (compared to bare metal stents), which was greatly attributed to a somewhat increased incidence of late and very late stent thrombosis. Concerns about the role of durable polymers as a potential trigger of inflammation and finally adverse events also led to the development of DES with bioresorbable coatings, which leave after degradation of the coating only a bare metal stent in the vessel wall that does not induce an inflammatory response. While such bioresorbable polymer DES are increasingly used in clinical practice, data from head-to-head comparisons between bioresorbable polymer DES with a contemporary highly flexible new generation permanent polymer coated DES.


Clinical Trial Description

rationale: The introduction of drug-eluting stents (DES) in the treatment of coronary artery disease has led to a significant reduction in morbidity. However, the first generation of these devices had no positive impact on the mortality after PCI (compared to bare metal stents), which was greatly attributed to a somewhat increased incidence of late and very late stent thrombosis. Concerns about the role of durable polymers as a potential trigger of inflammation and finally adverse events also led to the development of DES with bioresorbable coatings, which leave after degradation of the coating only a bare metal stent in the vessel wall that does not induce an inflammatory response. While such bioresorbable polymer DES are increasingly used in clinical practice, data from head-to-head comparisons between bioresorbable polymer DES with a contemporary highly flexible new generation permanent polymer coated DES.

Aim:

The aim of the study is to compare the outcome of the bioresorbable polymer coated stent (ORSIRO) and a new generation permanent polymer coated stent (RESOLUTE ONYX) in an all-comers patient population and non-inferiority setting.

Study design:

The study is a prospective, randomized, single-blinded, multicentre trial with 1:1 randomization for drug-eluting stent type, stratified for gender and the presence of diabetes mellitus.

Study population:

Patients who require percutaneous coronary intervention (PCI) for the treatment of coronary stenoses with an indication for DES use, according to current guidelines and/or the operators clinical judgement. All clinical syndromes will be included. A total of 2,470 patients will be included.

Intervention:

One group will receive the ORSIRO stent, the other group will receive the RESOLUTE ONYX stent. All other intervention and procedural characteristics are similar.

Primary study outcome:

Incidence of target vessel failure (TVF) at 1 year follow-up (according to ARC definitions). Components of the primary endpoint in hierarchical order: - Cardiac death: all deaths are considered cardiac, unless an unequivocal non-cardiac cause can be established. - Target vessel related myocardial infarction (MI) that is Q-wave or non-Q-wave, that can be related to the target vessel or cannot be related to another vessel. - Clinically driven repeated target vessel revascularization by means of PCI or coronary artery bypass grafting (CABG). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02508714
Study type Interventional
Source Thorax Centrum Twente
Contact
Status Active, not recruiting
Phase N/A
Start date October 7, 2016
Completion date March 2019

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A