Clinical Trials Logo

Clinical Trial Summary

This is a multicentre, prospective, randomized controlled trial that will investigate the role and performance of the 3rd generation resorbable magnesium scaffolds "DREAMS 3G" labeled under the name "Freesolve" vs contemporary biodegradable polymer scaffolds in non ST-segment elevation acute coronary syndromes. Patients fulfilling the eligibility criteria will be enrolled and undergo PCI with either Freesolve or Orsiro platforms for the culprit lesion only. They will be followed-up for 12 months (1, 6 and 12 months). The primary endopoint will be Target Lesion Failure as defined by ARC definitions.


Clinical Trial Description

INTRODUCTION AND RATIONALE Scaffolding the coronary vessels while maintaining the physiological and rheological properties was an appealing idea resulting in the development of the bioresorbable scaffolds (BRS). The most thoroughly studied BRS - the poly-L-lactide acid based BRS ABSORB™ - evidenced increased rates of device-related adverse events in the randomized controlled trials (RCT) and was removed from market in 2017. ABSORB was an everolimus eluting BRS, characterized by limited radial force, thicker and wider struts, unfavorable crossing profile and unpredictable resorption. In an effort to overcome these obstacles, metallic resorbable scaffolds were developed - with the main representative being the resorbable magnesium scaffolds (RMS). The absorbable metal stent (AMS) (BIOTRONIK AG, Bülach, Switzerland). was the first device tested in the PROGRESS-AMS trial showing feasibility but necessity for improvement. DREAMS 1G (BIOTRONIK AG, Bülach, Switzerland) was the first generation of the improved RMS, designed to improve radial force and coated with a paclitaxel-polymer matrix. It was studied in the BIOSOLVE-I and showed improved performance compared to the AMS with no probable or definite scaffold thrombosis, however late-lumen-loss (LLL) was relatively high compared to ABSORB scaffolds and contemporary drug eluting stents (DES). The second generation was the DREAMS 2G (BIOTRONIK AG, Bülach, Switzerland), gaining CE-Mark in 2016 and marketed as Magmaris™. It is designed with more flexible and stronger scaffold backbone targeting in improved radial force with 150x140μm strut thickness. The drug-polymer coating was substituted by the sirolimus BIOlute™ matrix of the Orsiro™ DES, to decrease more effectively neointimal formation. Also, radiopaque markers were added for enhanced x-ray visibility. The outcomes of Magmaris™ have been investigated in the BIOSOLVE II, III, IV trials. In summary, BIOSOLVE II and III demonstrated no scaffold thrombosis with improved LLL improved to its precursor and BIOSOLVE IV exhibited low event rates in a large single-arm study. The concept of protecting the vulnerable, eroded or ruptured plaque without a permanent metallic endoprosthesis finds ideal application in the acute coronary syndromes. Culprit lesions present as a ruptured plaque, plaque erosion or less frequently as a calcific nodule complicated by thrombotic burden and implantation of a BRS may adequately revascularize the vessel, protect the lesion and be resorbed after vessel healing restoring its elastic and hydraulic properties. However, the high thrombotic status of an acute coronary syndrome (ACS) was preventing BRS of being utilized in such situations. The TROFI-II RCT compared the ABSORB scaffold with DES in ST-segment elevation myocardial infarction (STEMI) and 6-month results were comparable. The Magmaris™ was tested in STEMI patients in the MAGSTEMI RCT and showed significantly higher vasodilatory response at 1-year compared to Orsiro™. Furthermore, Magmaris™ did not raise thrombotic concerns, but resulted in higher target lesion revascularization (TLR) rates although not powered for those endpoints. The BESTMAG trial was a small propensity-matching study providing hypothesis generating outcomes of numerically higher TLR rates with Magmaris™ compared to contemporary biodegradable polymer (BP) or durable polymer (DP)-DES in STEMI presentations. The BIOSOLVE IV registry (n=206) underwent PCI because of non ST-segment elevation (NSTE) myocardial infarction and target vessel failure (TVL) was calculated at 6.1% in 12 months. One death (0.5%) and 2 thrombotic complications were reported (1%). Smaller registries that included NSTE/ACS patients treated with Magmaris™ RMS demonstrated zero deaths and scaffold thrombosis, albeit these are hypothesis generating results limited by the small sample. The BIOMAG-I first-in-human study investigated the third generation Freesolve™ RMS. The main characteristics are a refined magnesium alloy to enhance scaffolding properties, increased scaffold marker x-ray visibility, larger size range, thinner strut thickness and predictable full resorption in about 12 months. The 1-year results of the BIOMAG-I showed lower LLL (38% lower) than the BIOSOLVE II, low target lesion failure (TLF) rates and no death, target vessel myocardial infarction (MI) or scaffold thrombosis. Of note no struts ware visible in the 1-year optical coherence tomography (OCT). 20.7% of the patients presented with NSTE myocardial infarction lesions and were treated accordingly. The current guidelines of the European Society of Cardiology recommend use of the BRS only in the context of clinical trials. However, more data and devices are available to hypothesize that RMS may provide a potentially reliable and safe alternative to DES. This trial will further investigate and evaluate the safety and efficacy of the 3rd generation Freesolve™ RMS in NSTE/ACS patients. STUDY PROCEDURES Screening Patients who will undergo coronary angiography because of NSTE/ACS will be screened for eligibility criteria after signing the informed consent. Demographics, medical history, clinical examination, 12-lead electrocardiogram and per local practice blood laboratory tests will be performed. For women of child-bearing potential, a blood pregnancy test must be performed. Randomization - enrolment Patients screened and fulfilling eligibility criteria will be enrolled after signing the informed consent form as per RESORB-ACS enrolment and follow-up algorithms (Figure 1). They will be randomly assigned in 1:1 ratio to receive either the Freesolve™ RMS or the BP DES Orsiro® for the PCI of the index NSTE/ACS culprit vessel. The Intention to Treat (ITT) and the Per Protocol (PP) population will only be based on enrolled subjects. Index PCI All patients enrolled will undergo PCI of the culprit lesion according on the local practice. The instruction for use (IFU) will be followed for every scaffold implantation. In the BP DES arm, the standard DES PCI procedure per local practice will be followed. Post-procedural care Patients enrolled that have undergone PCI will receive standard NSTE/ACS and post-PCI care in each centre. Double antiplatelet treatment is recommended for at least 12 months. Follow-up Follow-up will be performed at 1, 6, 12 months and annually up to 36 months follow-up. (visit window ± 10 days). In case that there is no adverse event or complaint from the patient that requires physical examination, the follow-up visits may be conducted through telephone or video call with the investigators. Study exit Screen failure, withdrawal of the informed consent, lost to follow-up and PCI without scaffold implantation will result in early termination. Study completion Subject who completes all protocol-required study procedures and follow-ups will complete the trial. Examinations Clinical examination including angina status or myocardial ischemia, 12-lead electrocardiogram and per local practice blood laboratory tests including will be performed at screening, and during hospitalization post-PCI. Follow-ups will be clinically driven with thorough history primarily focused on any possible myocardial ischemia symptoms. Based on the investigators' - treating physicians' clinical suspicion more examination may be performed to investigate the existence of adverse events/endpoints. PROCEDURAL DETAILS The device The Freesolve™ scaffold is a Magnesium alloy fully resorbable scaffold developed by BIOTRONIC and represents the 3rd generation of RMS (DREAMS 3G). It is indicated for improving the luminal diameter for treatment of de novo coronary artery lesions by PCI. Freesolve™ is a scaffold system consisting of a balloon-expandable bioabsorbable scaffold pre-mounted on the balloon of a rapid-exchange PTCA catheter. The scaffold backbone is made from bioabsorbable Magnesium and contains two permanent x-ray markers made from Tantalum on the distal and on the proximal scaffold end, respectively. The surface of the scaffold backbone is completely coated with bioresorbable PLLA (Poly-L-Lactidic Acid) which incorporates Sirolimus. Sirolimus load is 1.4 ± 0.3 μg per mm2 scaffold surface. The DREAMS 3G scaffold system is packaged in a dispenser. The dispenser is placed in an aluminium Tyvek pouch. The device is sterilized using ethylene oxide sterilization. In vivo investigations using a porcine model show that DREAMS 3G provides vessel support for about 3-6 months and releases around 70% Sirolimus from the PLLA carrier during a period of 3 months after implantation. The drug coating is based on the BIOlute® platform. Training The operators and the operating teams that are going to participate in this protocol and implant the RMS have to be trained on the consensus paper by Fajadet et al. and follow the "4P" principles. Device implantation - procedure The RMS Freesolve™ is available in 2.5mm, 3mm, 3.5mm and 4mm diameter and in 13mm, 22mm length for all diameters and 26mm/30mm length for the 3mm, 3.5 mm and 4mm diameters. It can be expander after post-dilatation up to 0.6mm in diameter. Nominal pressure for implantation inflation is 10atm and rated burst pressure 16atm. It is delivered through 6Fr guiding catheter and over angioplasty 0.014'' wires. Following intracoronary injection of nitroglycerin or isosorbide dinitrate, a baseline angiography of the target vessel must be performed in at least 2 orthogonal views, presenting the target lesion free of foreshortening or vessel overlap. In addition to the clinical routine, OCT and intravascular ultrasound (IVUS) documentation may be done pre-PCI per operator's discretion. By intravascular imaging, detailed examination of the lesion as well as accurate length and reference diameter can be performed. Lesion access is up to the discretion of the investigator. Pre-dilatation of the target lesion is mandatory. The use of intravascular lithotripsy, drug coated balloons or rotational/orbital atherectomy device is not allowed. Pre-dilatation with a non-compliant balloon with a 1:1 balloon-to-artery ratio is mandatory. The balloon should expand fully with no "waist" at full expansion. Non-compliant balloons are more predictable and are recommended. The residual stenosis before the RMS implantation is required to be ≤ 20%, confirmed by any method and TIMI flow should be III. The scaffold length should cover the target lesion from normal reference vessel diameter proximally to normal vessel distally to assure full coverage of the lesion. The diameter of the RMS should be chosen as following: 2.5mm for 2.5-2.7mm distal reference diameter (DRD), 3.0mm for 2.7-3.2mm DRD, 3.5mm for 3.2-3.7mm DRD, 4.0mm for 3.7-4.2 DRD. The length should be chosen based on the lesion length by angiography or IVUS, OCT. Only one clinical investigation scaffold should be used per lesion. After scaffold implantation an angiography must be performed following intracoronary injection of nitroglycerine or isosorbide dinitrate. Post-dilatation with a non-compliant balloon of up to 0.5 mm larger than the nominal scaffold size and at high pressure (>16 atm) is mandatory. The use of cutting/scoring or drug coated balloons after RMS implantation is not allowed. After post-dilatation, all subjects will undergo the routine angiography and possibly OCT/IVUS. Intravascular imaging may evaluate expansion, apposition and any possible edge or in-scaffold complication. Culprit lesion In NSTE/ACS identification of the culprit lesion might be challenging. Investigational data with cardiac magnetic resonance imaging identification has showed that in up to 27% of the NSTE/ACS patients' revascularization has been performed in non-culprit lesions. Moreover, electrocardiographic identification is neither sensitive nor specific and recent data demonstrated that in 14% of the studied patients, conventional angiography failed to identify the culprit lesion. In those ambiguous cases, intravascular imaging with IVUS or OCT plays a critical role in the characterization and identification of the culprit lesion. In the RESORB-ACS trial, operators will decide about the possible culprit lesion and that decision may be assisted and guided by intravascular imaging in case it is needed. Multivessel disease Multivessel disease is not an exclusion criterion except for the cases that CABG is programmed. Enrolled subjects may undergo PCI with RMS only for the culprit lesion during the index procedure. However, in cases that multivessel disease amenable to PCI is present, operators can proceed to full revascularization with conservative DES or Freesolve™ RMS. Treatment failure and bailout situation For dissections occurring during, or immediately after implantation of RMS, a second RMS may be used, not overlapping with initial one but implanted end-to- end. If another stent needs to be implanted in the immediate vicinity of an already implanted RMS only a Freesolve™ coronary scaffold system should be used. Contact of the Freesolve™ with an uncoated or polymer coated stent up to 120 days may result in accelerated resorption of the DREAMS 3G and undesired local and downstream effects. After 120 days any other stent type may be used. In case of bailout, If a Freesolve™ is not possible to be used, an Orsiro® DES with its proBIO® passive coating and BIOlute® active coating is recommended to be implanted directly adjacent or minimally overlapping based on the consensus recommendations. Medication Every patient included in this trial must be able to receive 12-month DAPT with aspirin and clopidogrel or ticagrelor or prasugrel. The timing and necessity (in case the patient was already under antiplatelet treatment) will be at the discretion of the treating physician. At all cases DAPT must be present at the time of the implantation based on the ESC guidelines doses for the management of ACS. The use of anticoagulation during PCI (heparin or enoxaparine) at therapeutic dose for PCI will be chosen by the operators. IIb/IIIa glycoprotein inhibitors as well as vasomotor medications will be left at operators' discretion. After the PCI, all patients must receive at least 12-month DAPT. After 12 months, DAPT may be changed to single treatment with aspirin/clopidogrel/ticagrelor/prasugrel or prolonged based on the balance of ischemic/hemorrhagic risk of the patient. Regarding patients receiving oral anticoagulation (eg atrial fibrillation, prosthetic valve, thrombophilia) we recommend that DAPT should be maintained until 1-month follow-up. Afterwards DAPT can be downsized to either aspirin or clopidogrel alone combined with oral anticoagulant for the remaining time period up to 12 months. After 12 months, monotherapy with oral anticoagulant may be prescribed and continued indefinitely. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06409117
Study type Interventional
Source National and Kapodistrian University of Athens
Contact Leonidas Koliastasis, MD, PhD
Phone 6974270752
Email lkoliastasis@gmail.com
Status Not yet recruiting
Phase Phase 4
Start date October 1, 2024
Completion date December 31, 2027

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A