Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05134051
Other study ID # 2020/066
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date October 6, 2020
Est. completion date December 31, 2021

Study information

Verified date July 2022
Source Cardiac Research Institute BV
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Due to differences in the mechanism of action, intravascular lithotripsy is likely to cause less distal embolization and microcirculatory dysfunction during plaque preparation. This may also translate into lower periprocedural myocardial infarction rates. Thus, this exploratory study aims to evaluate the microcirculatory function after the use of Shockwave® intravascular lithotripsy.


Description:

Patients with stable coronary artery disease or stabilized acute coronary syndromes with severely calcified de novo coronary stenoses with indication of plaque modification technique during PCI. Due to differences in the mechanism of action, intravascular lithotripsy is likely to cause less distal embolization and microcirculatory dysfunction during plaque preparation. This may also translate into lower periprocedural myocardial infarction rates. To perform the invasive physiology assessment an intracoronary pressure and temperature sensor-tipped guidewire is used to measure distal coronary pressure and to derive thermodilution curves. For the calculation of IMR three thermodilution curves can be obtained from a hand-held, 3-ml rapid (<0.25s) injection of room temperature saline at baseline and during maximal hyperemia. Mean transit time (Tmn) at baseline and during maximal hyperemia is derived from the thermodilution curves. Simultaneous recordings of mean aortic pressure (guiding catheter, Pa) and mean distal coronary pressure (distal pressure sensor, Pd) is also obtained at baseline and during maximal hyperemia. The IMR is then calculated using the following equation: IMR = PaxTmn[(Pd-Pw)/(Pa-Pw)], where Pw is the coronary wedge pressure. Pw will be measured as the distal coronary pressure (from the distal pressure and temperature sensor) during complete balloon occlusion of the vessel obtained during PCI. The aim of the present study is to investigate the protective effect of IVL (Shockwave© Medical) on the coronary microcirculatory during PCI in calcific coronary stenosis, compared to RA.


Recruitment information / eligibility

Status Completed
Enrollment 20
Est. completion date December 31, 2021
Est. primary completion date December 1, 2021
Accepts healthy volunteers No
Gender All
Age group N/A and older
Eligibility Inclusion Criteria: - Angiographic inclusion criteria - Severely calcified stenoses - Vessels with RVD between 2.5 - 4.0 mm - TIMI flow 3 Exclusion Criteria: - Angiographic exclusion criteria - Concomitant use of rotational atherectomy - Severe vessel tortuosity - Stenosis un-crossable with a balloon/guidewire - Concomitant conditions - Contraindication for adenosine administration. - Hemodynamic or electrical instability. - Active liver disease or hepatic dysfunction, defined as AST or ALT > 3 times the ULN. - Severe renal dysfunction, defined as an eGFR <30 mL/min/1.73 m2, unless the patient is in renal support therapy. - Other exclusion criteria - Unable to provide written informed consent (IC) - Known pregnancy or breast-feeding at time of inclusion; pre-menopausal women, unless sterilized, must take an effective method of birth control up to 15 weeks after the end of treatment with IP - Prior myocardial infarction subtended to the PCI target vessel. - Akinesia or dyskinesia in myocardial segments in the distribution area of the PCI target vessel. - Severe systolic dysfunction defined as left ventricular ejection fraction < 35%. - Patent arterial or venous surgical graft supplying the PCI target vessel. - Previous TIMI flow < 1 before guidewire crossing. - Patient not eligible for drug-eluting stent treatment.

Study Design


Intervention

Device:
Shockwave® Intravascular Lithotripsy System (Shockwave Medical Inc)
IVL is a novel balloon catheter-based device that utilises pulsatile mechanical energy to disrupt calcified lesions. IVL differs from other types of lithotripsy with respect to depth of penetration. It is a single-use, sterile, disposable balloon catheter. The emitters convert electrical energy into transient acoustic circumferential pressure pulses that disrupt both superficial and deep calcium within plaque. The balloon catheter is connected to the generator, which is programmed to deliver the specified dosage of pulses. The IVL balloon, sized 1:1 to the reference artery ratio, is inflated low pressure (4 atm) with 10 pulses of ultrasound energy of 10s delivered per balloon. The procedure is repeated to provide a minimum of 20 pulses in the target lesion, with interval deflation to allow distal perfusion. Each catheter can emit a max of 80 pulses at a rate of one pulse per second. If the lesion exceeds the 12mm balloon length, the balloon can be repositioned and the IVL repeated.

Locations

Country Name City State
Spain Hospital San Carlos Madrid

Sponsors (1)

Lead Sponsor Collaborator
Cardiac Research Institute BV

Country where clinical trial is conducted

Spain, 

Outcome

Type Measure Description Time frame Safety issue
Primary Index of Microcirculatory Resistance (IMR) after IVL through study completion, an average of 1 year
Secondary Post-PCI FFR after IVL through study completion, an average of 1 year
Secondary Rate of periprocedural myocardial infarction through study completion, an average of 1 year
See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A