Clinical Trials Logo

Clinical Trial Summary

New-generation metallic drug-eluting stents represent the standard of care among patients undergoing percutaneous coronary intervention (PCI). Currently, few data are available as regards to the safety and efficacy of the Cre8 amphilimus-eluting stent (Cre8 AES, Alvimedica, Instanbul, Turkey) in comparison with the biodegradable polymer everolimus-eluting stent (Synergy EES, Boston Scientific, Marlborough, MA, USA). Results from randomized trials and meta-analyses consistently indicate that prolonged dual antiplatelet therapy (DAPT) after PCI reduces ischemic events, but invariably conveys an excess of clinically relevant bleeding, which is proportional to the duration of treatment. It has been estimated, indeed, that for every non-fatal ischemic event avoided with prolonged DAPT, two or more clinically relevant bleeding events have to be expected. Given the trade-off between benefits and risks and the lack of mortality benefit in favor of prolonged DAPT, expert consensus suggests that DAPT duration should be individualized based on ischemic versus bleeding risks. At this regard, the DAPT score has been recently proposed as standardized tool to identify patients who derive benefit or lack from a prolonged course of DAPT. However, a prospective assessment of the DAPT score is lacking and whether a personalized duration of DAPT based on the DAPT score improves the net clinical benefit remains unknown. The objective of the study is to compared the safety and the efficacy of the Cre8 AES with the Synergy EES and a personalized DAPT duration based on the DAPT score with a standard DAPT duration among patients undergoing PCI.


Clinical Trial Description

The objective of the trial is: i) to evaluate the efficacy and safety of the Cre8 AES vs. the Synergy EES in a broadly unselected patient population with coronary artery disease undergoing PCI; ii) to compare the safety and efficacy of a personalized DAPT duration (3-, 6-, or 24-month) guided by the application of the DAPT score with a standard DAPT duration (12-month) after PCI. In particular, the objectives of the trial are to test the following hypothesis: - The Cre8 AES is non-inferior to the Synergy EES with regards to a device-oriented composite endpoint (DOCE) at 1-year follow-up. - A personalized DAPT duration based on the DAPT score is superior to a standard DAPT duration with regards to a net adverse clinical endpoint (NACE) at 2-year follow-up. This is a prospective, randomized, multicenter, investigator-initiated, assessor-blind trial to be conducted at interventional cardiology centers in Italy. Patients undergoing PCI will be randomized in a 2-by-2 randomization fashion to undergo PCI with the Cre8 AES or Synergy EES and to receive a personalized or standard DAPT duration. All patients will be followed at 3-, 6-, 12- and 24-month after PCI for clinical endpoints. Use of experimental and control DES: Both the study stent (Cre8 AES) and the control stent (Synergy EES) will be used according to their indications for use. The randomly assigned stent is not expected to have an influence on the conduct of the procedure that will take place according to the routine practice. Eligible patients will undergo PCI as per local protocol, according to current guidelines of the European Society of Cardiology on myocardial revascularization. The technique of PCI (vascular access route, choice of the vascular sheath diameter, choice of the diagnostic and guiding catheters sizes and shapes, choice of the coronary guidewire) will be left to the discretion of the operator as per standard individual and local practice. The operator will choose the appropriate length and diameter of the stents to be implanted by visual estimate or quantitative coronary angiography as per local practice. The Cre8 AES and the Synergy EES systems are commercially available and all sizes may be used for the study. DAPT duration according to randomization: DAPT duration in patients randomized to personalized DAPT regimen: In patients that are randomized to a personalized DAPT and have a low DAPT score (<2), DAPT duration is recommended for 3 months in case of stable coronary artery disease at the time of the index procedure or for 6 months in case of acute coronary syndrome at the time of the index procedure. A low dose of aspirin (75 to 162 mg daily) will be administered throughout the course of the study. In patients that are randomized to a personalized DAPT and have a high DAPT score (≥2), DAPT duration is recommended for 24 months. Changes in the dose or in the type of P2Y12 receptor inhibitor (clopidogrel, prasugrel, or ticagrelor) are allowed during the course of the study. A low dose of aspirin (75 to 162 mg daily) will be administered throughout the course of the study. At 12-month, patients on treatment with prasugrel or ticagrelor should continue the same P2Y12 receptor inhibitor. In this specific scenario, it is preferable to continue with the same P2Y12 receptor inhibitor (prasugrel 10 mg daily or ticagrelor 90 mg daily) or to switch to a low-dose regimen of ticagrelor (60 mg twice daily) if clinically indicated or to switch to clopidogrel (75 mg daily). DAPT regimen in patients in patients randomized to a standard DAPT duration: In patients that are randomized to a standard DAPT duration, oral P2Y12 inhibitors (clopidogrel, prasugrel, or ticagrelor) should be administered for 12-month. A low dose of aspirin (75 to 162 mg daily) will be administered throughout the course of the study. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04135989
Study type Interventional
Source Federico II University
Contact
Status Active, not recruiting
Phase Phase 4
Start date January 1, 2020
Completion date October 24, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Coronary De Novo Lesions N/A