Comparison of the capsular bag performance of two extended depth of vision (EDOF) intraocular lenses (IOLs), the Rayone EMV and the Alcon Acrysof IQ Vivity, in a mini-monovision setting


Clinical Trial Description

Spectacle independence is a rising aim in modern cataract surgery. Although bilateral monofocal IOL implantation, aiming for emmetropia leads to high levels of patient satisfaction for distance vision, spectacle dependence for reading and intermediate vision tasks is the usual result. The option commonly used to achieve spectacle independence in all distances are multifocal intraocular lenses. One concept of multifocality is the trifocal lens. This lens provides good vision in three focal distances: far, intermediate, and near. However, one potential disadvantage of trifocal IOLs is slightly poorer near vision with need for reading gasses for prolonged fine near work and loss of contrast sensitivity in the intermediate distance. A better intermediate performance concerning contrast vision compared to trifocal IOLs can be reached using enhanced depth of focus (EDOF) lenses. These IOLs have an extended far focus area, which reaches to the intermediate distance, providing high-quality vision over a continuous range of focus, rather than distinct foci with blur in between. In the last years several technologies for EDOF IOLs appeared on the market. The disadvantage compared to monofocal lenses in all of these technologies is the potentially worse contrast sensitivity as well as dysphotopsia. A new monofocal non-diffractive lens with an extended depth of vision (Rayone EMV) promises an increased range of functional vision and less dysphotopsias. Especially in a monovision setting, where the dominant eye is set for emmetropia and the other eye for low myopia is believe dto be a promising concept for spectacle independence. Hence, the aim of this study is to compare a new monofocal IOL wit a non-diffractive extended depth of vision (Rayone EMV) with an already established non-diffractive EDOF IOL (Alcon Acrysof IQ Vivity) in a mini-monovision setting. 96 eyes of 48 patients will be included into this study. After randomization, each patient will either receive the Rayone EMV or the Alcon Acrysof IQ Vivity in both eyes. Follow-up visits will be 2 weeks and 3 months after surgery. During these visits a slitlamp examination, measurement of the intraocular pressure, visual acuity assessment, pupil size measurement, determination of the defocus curve, contrast sensitivity measurements, reading speed detection, and a flaremeter measurement will be performed. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05194150
Study type Interventional
Source Vienna Institute for Research in Ocular Surgery
Contact Johannes Zeilinger, MD
Phone 01 91021
Email office@viros.at
Status Recruiting
Phase N/A
Start date January 3, 2022
Completion date January 3, 2024

See also
  Status Clinical Trial Phase
Completed NCT04998409 - Evaluation of a Spherical Hydrophilic Acrylic Intraocular Lens
Completed NCT04252716 - VISPER: Randomised Comparison of Two OVDs in Cataract Surgery
Recruiting NCT05110222 - Cataract Lens Hardness Based on Phaco Tip Resistance
Recruiting NCT04266847 - Prospective Clinical Study of Preoperative and Postoperative Unilateral Mild Cataract Patients N/A
Recruiting NCT04175951 - Tecnis Eyhance Versus Rayner RayOne Study N/A
Recruiting NCT04572334 - Eyhance Autorefraction Study N/A
Completed NCT04140383 - Cataract Surgery In Patients With Advanced Age
Active, not recruiting NCT04570579 - Impact of a Novel Extended Depth of Focus Intraocular Lens on Visual and Lifestyle Enhancement
Completed NCT05347615 - Achieving Hybrid Monovision By Paring Monofocal And EDOF Lens Technology
Recruiting NCT05129566 - Evaluation of Axial Stability of Two Models of Intraocular Lenses in Patients With an Eye Length More Than 26 mm N/A
Recruiting NCT05148507 - Optimization of the Ocular Surface Prior to Cataract Surgery Using PROKERA N/A
Completed NCT04655274 - Comparision of Visual Outcomes and Patient Satisfaction Between Two Diffractive Trifocal Intraocular Lenses
Completed NCT04255706 - Repeatability in Measurements of Two ssOCT and One OLCR Biometer N/A
Completed NCT05287269 - Ocular Coherence Tomography During Cataract Assessment
Completed NCT04545671 - Evaluation of a Trifocal Lens
Completed NCT04580550 - Axial Length Variability N/A
Recruiting NCT04265846 - Prospective Clinical Study of Different Intraocular Lens Implantation Designed for the Correction of Presbyopia
Completed NCT03970525 - Venturi and Peristaltic Based Phacoemulsification in Femtosecond Laser Cataract Surgery
Completed NCT04333056 - Comparison Between Two Ss-OCT Biometry
Completed NCT05578339 - Predicting the Lens Capsular Bag Size Using Pre-operative Biometry N/A