Clinical Trials Logo

Clinical Trial Summary

This study will compare two methods of vacuum (peristaltic or venturi) commonly used during the removal of a femtosecond treated cataract. The investigators will observe which method uses less energy, is gentler on the eye, reduces corneal swelling and if the vision recovers faster with one method compared to the other.


Clinical Trial Description

This is an open, prospective, randomized study to evaluate efficiency and outcomes of femtosecond laser cataract surgery with phacoemulsification performed with one of two standard vacuum systems. It is estimated that the duration of study participation will be up to 24 months. There will be randomization to 1 of 2 groups. Both eyes of each subject will be enrolled in the study. The first eye will be randomized to either the Venturi or peristaltic-based vacuum pump. The second eye will then receive the other type of vacuum pump for that procedure. Study Phases: Pre-operative Visit Procedure Post-operative Follow up The subject will be seen 1 day, 5-10 days, and 90 days following the procedure. Surgical Procedure - The cataract removal procedure will be performed under sterile technique and according to standard procedures. The femtosecond laser treatment will be followed by phacoemulsification removal of the cataract and implantation of an intraocular lens. - Peri-operatively, subjects will be treated with a regimen of antibiotic, steroid and nonsteroidal anti-inflammatory eye drops per standard of care. - All surgeries will be performed by the same experienced surgeon/principal investigator using the Catalys® SYSTEM femtosecond laser platform and WHITESTAR SIGNATURE® PRO Phacoemulsification System. - Phacoemulsification Settings: - For Venturi pump: 600 mmHg vacuum - For Peristaltic-based pump: 600 mmHg vacuum and aspiration flow of 50 mL/min - Other settings: ultrasound energy application parameters will be the same for the two groups Study Procedures - The study will include routine cataract pre-operative testing with Nidek OPD, Galilei G4, and IOLMaster, and repeated at the post-op visits. An endothelial cell count of the cornea will be performed at the pre-operative visit and at the 90 day follow up visit. - Subjects will be randomized to phacoemulsification settings of Venturi vacuum of 600 mmHg or peristaltic vacuum of 600 mmHg and aspiration flow of 50 mL/min. All other phacoemulsification settings will be identical. The laser settings will be based on the grade of cataract only and will not be altered for this study. - The phacoemulsification time, energy Ellips FX EFX, and average phacoemulsification energy will be recorded. The laser procedure time and total procedure time will be recorded. Complications will be recorded. Additional patient characteristics will also be recorded. - Pre-Operative Visit: - Nidek Refractive Power/Corneal Analyzer OPD-Scan, Galilei G4 Corneal Topography, IOLMaster 700 keratometry (standard of care) - Complete eye examination (standard of care) - Brightness Acuity Test (BAT) (standard of care) - Review and confirm eligibility (research) - Informed Consent for study (research) - Randomization (research) - Endothelial Cell Count (research) - Medical Record Review (research) - Surgical Procedure (Day 0) (standard of care) - Medical Record Review (research) - Adverse Event Assessment (research) - Post-operative Visit 1 (Day 1): - Eye exam to include uncorrected and pinhole visual acuity, Intraocular pressure (IOP) and slit-lamp exam (standard of care) - Galilei G4 Corneal Topography, IOLMaster 700 keratometry (standard of care) - Medical Record Review (research) - Adverse Event Assessment (research) - Post-operative Visit 2 (Day 5-10): - Eye exam to include uncorrected and best corrected visual acuity, Pinhole visual acuity, IOP, and slit-lamp exam (standard of care) - Nidek Refractive Power/Corneal Analyzer OPD-Scan, Galilei G4 Corneal Topography, IOLMaster 700 keratometry (standard of care) - Medical Record Review (research) - Adverse Event Assessment (research) - Post-operative Visit 3 (Day 60-90 days): - Eye exam to include uncorrected and best corrected visual acuity, Pinhole visual acuity, IOP, and slit-lamp exam (research) - Nidek Refractive Power/Corneal Analyzer OPD-Scan, Galilei G4 Corneal Topography, IOLMaster 700 keratometry (research) - Endothelial Cell Count (research) - Medical Record Review (research) - Adverse Event Assessment (research) - Unscheduled Visit: - A medical record review and an adverse event assessment will be performed at any unscheduled visit. - Additional evaluations will be completed at the discretion of the Principal Investigator based on the subject's presenting complaint. Statistical Analysis Sample Size and Power: · The study aims to enroll 250 study subjects for a total of 500 eyes with bilateral grade 1-3 nuclear sclerotic cataracts who will be undergoing planned femtosecond laser cataract surgery. Statistical Methods: · The statistical analysis plan will include use of descriptive statistics and statistical tests including unpaired t-tests. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03970525
Study type Observational
Source Mercy Research
Contact
Status Completed
Phase
Start date May 16, 2019
Completion date March 29, 2023

See also
  Status Clinical Trial Phase
Completed NCT04998409 - Evaluation of a Spherical Hydrophilic Acrylic Intraocular Lens
Completed NCT04252716 - VISPER: Randomised Comparison of Two OVDs in Cataract Surgery
Recruiting NCT05110222 - Cataract Lens Hardness Based on Phaco Tip Resistance
Recruiting NCT04266847 - Prospective Clinical Study of Preoperative and Postoperative Unilateral Mild Cataract Patients N/A
Recruiting NCT04175951 - Tecnis Eyhance Versus Rayner RayOne Study N/A
Recruiting NCT04572334 - Eyhance Autorefraction Study N/A
Completed NCT04140383 - Cataract Surgery In Patients With Advanced Age
Active, not recruiting NCT04570579 - Impact of a Novel Extended Depth of Focus Intraocular Lens on Visual and Lifestyle Enhancement
Completed NCT05347615 - Achieving Hybrid Monovision By Paring Monofocal And EDOF Lens Technology
Completed NCT05129566 - Evaluation of Axial Stability of Two Models of Intraocular Lenses in Patients With an Eye Length More Than 26 mm N/A
Recruiting NCT05148507 - Optimization of the Ocular Surface Prior to Cataract Surgery Using PROKERA N/A
Completed NCT04655274 - Comparision of Visual Outcomes and Patient Satisfaction Between Two Diffractive Trifocal Intraocular Lenses
Completed NCT04255706 - Repeatability in Measurements of Two ssOCT and One OLCR Biometer N/A
Completed NCT05287269 - Ocular Coherence Tomography During Cataract Assessment
Completed NCT04545671 - Evaluation of a Trifocal Lens
Completed NCT04580550 - Axial Length Variability N/A
Recruiting NCT04265846 - Prospective Clinical Study of Different Intraocular Lens Implantation Designed for the Correction of Presbyopia
Completed NCT04333056 - Comparison Between Two Ss-OCT Biometry
Completed NCT05578339 - Predicting the Lens Capsular Bag Size Using Pre-operative Biometry N/A
Completed NCT03162471 - How Astigmatism Influences Corneal Biomechanics and Intraocular Pressure N/A