Some parameters, such as a change in the optic tilt and axial decentration, can affect the optical characteristics of intraocular lenses (IOLs) in postoperative period, which leads to residual refractive errors and other complications. The stability of the intraocular lens in the eye is largely dependent on the mechanical design of its haptic support elements. Thus, the new Clareon IOL has a flat haptic with a flexible design that minimizes axial changes and allows the IOL to maintain a stable position in a given plane during compression. Currently there is no published data of the stability for Clareon AutonoMe IOL for long eyes. The purpose of the current study is to evaluate and compare the axis displacement and stability of optical tilt, visual and refractive results in patients after implantation of two different models of intraocular lenses: Clareon AutonoMe (Alcon, USA) and Hoya iSert 251 (Japan) in the long-term postoperative period (after cataract surgery).


Clinical Trial Description

The optical performance of intraocular lenses (IOLs) can be affected by changes in optic tilt and decentration that occur after implantation, resulting in residual refractive errors and other complications. Intraocular lens stability is largely dependent on the mechanical design of the haptics. Clareon IOL has a flat haptic with a flexible design that minimizes axial changes and allows the IOL to maintain a stable position in a given plane during compression. Based on our knowledge, nobody has compared Clareon AutonoMe and Hoya iSert 251 IOLs in clinical setting. Scientific Rationale: This study investigates the stability of IOLs in patients with long axial length. IOL stability on long eyes has a limited clinical data, no in Vivo research has been done. It is known that eyes with long axial length have a large capsule bag. With such eyes, it is difficult to predict the effective lens position. Each 0,5 mm axial displacement lead to approximately 0,5 D of the refractive error. For long eyes, it is important to use the latest generation of multi-component IOL calculation formulas for accurately prediction of effective lens position. The mail purpose of the study is to evaluate and compare the axis displacement and stability of optical tilt, visual and refractive results in patients after implantation of two different models of intraocular lenses: Clareon AutonoMe (Alcon, USA) and Hoya iSert 251 (Japan) in the long-term postoperative period (after cataract surgery). The research purpose is to evaluate the prediction error for each IOL calculation formula (Barrett Universal II, Kane, EVO, Holladay I with Van Koch correction) ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05129566
Study type Interventional
Source The S.N. Fyodorov Eye Microsurgery State Institution
Contact Olga V Fomina, MD, PhD
Phone +79855172351
Email fomina.ov.ophthalmologist@mail.ru
Status Recruiting
Phase N/A
Start date October 1, 2021
Completion date November 2022

See also
  Status Clinical Trial Phase
Completed NCT04998409 - Evaluation of a Spherical Hydrophilic Acrylic Intraocular Lens
Completed NCT04252716 - VISPER: Randomised Comparison of Two OVDs in Cataract Surgery
Recruiting NCT05110222 - Cataract Lens Hardness Based on Phaco Tip Resistance
Recruiting NCT04266847 - Prospective Clinical Study of Preoperative and Postoperative Unilateral Mild Cataract Patients N/A
Recruiting NCT04175951 - Tecnis Eyhance Versus Rayner RayOne Study N/A
Recruiting NCT04572334 - Eyhance Autorefraction Study N/A
Completed NCT04140383 - Cataract Surgery In Patients With Advanced Age
Active, not recruiting NCT04570579 - Impact of a Novel Extended Depth of Focus Intraocular Lens on Visual and Lifestyle Enhancement
Completed NCT05347615 - Achieving Hybrid Monovision By Paring Monofocal And EDOF Lens Technology
Recruiting NCT05148507 - Optimization of the Ocular Surface Prior to Cataract Surgery Using PROKERA N/A
Completed NCT04655274 - Comparision of Visual Outcomes and Patient Satisfaction Between Two Diffractive Trifocal Intraocular Lenses
Completed NCT04255706 - Repeatability in Measurements of Two ssOCT and One OLCR Biometer N/A
Completed NCT05287269 - Ocular Coherence Tomography During Cataract Assessment
Completed NCT04545671 - Evaluation of a Trifocal Lens
Completed NCT04580550 - Axial Length Variability N/A
Recruiting NCT04265846 - Prospective Clinical Study of Different Intraocular Lens Implantation Designed for the Correction of Presbyopia
Completed NCT03970525 - Venturi and Peristaltic Based Phacoemulsification in Femtosecond Laser Cataract Surgery
Completed NCT04333056 - Comparison Between Two Ss-OCT Biometry
Completed NCT05578339 - Predicting the Lens Capsular Bag Size Using Pre-operative Biometry N/A
Completed NCT03162471 - How Astigmatism Influences Corneal Biomechanics and Intraocular Pressure N/A