Cataract Senile Clinical Trial
Official title:
Comparison of Two Swept-Source Optical Coherence Tomography-based Biometry Devices
Since recently a second swept-source optical coherence tomography (ss-OCT) optical biometry
device was launched (Anterion, Heidelberg Engineering). Aim of this study is a retrospective
data collection of patients who were measured with both ss-OCT optical biometry devices and
to assess the limits of agreement of the two devices.
Retrospective comparison of two ss-OCT biometry devices concerning comparability of
measurements of axial eye length, anterior chamber depth, lens thickness and keratometry.
This a retrospective study including data acquired from patients that attended pre-surgical
examination as it is the standard in the investigator's hospital.
The IOL Master 700 (Carl Zeiss Meditec AG, Jena) and the Heidelberg Anterion (Heidelberg
Engineering, Germany) are biometry devices that use swept-source optical coherence tomography
technology in combination with a multidot-keratometer, that obtain two-dimensional images of
ocular structures.
The difference between the two devices resides in the wavelength of the infrared laser:
1200-1400nm for the Anterion and 1050nm for the IOL Master 700.
The SS-OCT devices provide a scan depth of 44mm and a resolution in tissue of 22 μm for the
IOL Master 700 and of 14x16.5 mm and 30 μm for the Heidelberg Anterion.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04998409 -
Evaluation of a Spherical Hydrophilic Acrylic Intraocular Lens
|
||
Completed |
NCT04252716 -
VISPER: Randomised Comparison of Two OVDs in Cataract Surgery
|
||
Recruiting |
NCT05110222 -
Cataract Lens Hardness Based on Phaco Tip Resistance
|
||
Recruiting |
NCT04266847 -
Prospective Clinical Study of Preoperative and Postoperative Unilateral Mild Cataract Patients
|
N/A | |
Recruiting |
NCT04175951 -
Tecnis Eyhance Versus Rayner RayOne Study
|
N/A | |
Recruiting |
NCT04572334 -
Eyhance Autorefraction Study
|
N/A | |
Completed |
NCT04140383 -
Cataract Surgery In Patients With Advanced Age
|
||
Active, not recruiting |
NCT04570579 -
Impact of a Novel Extended Depth of Focus Intraocular Lens on Visual and Lifestyle Enhancement
|
||
Completed |
NCT05347615 -
Achieving Hybrid Monovision By Paring Monofocal And EDOF Lens Technology
|
||
Completed |
NCT05129566 -
Evaluation of Axial Stability of Two Models of Intraocular Lenses in Patients With an Eye Length More Than 26 mm
|
N/A | |
Recruiting |
NCT05148507 -
Optimization of the Ocular Surface Prior to Cataract Surgery Using PROKERA
|
N/A | |
Completed |
NCT04655274 -
Comparision of Visual Outcomes and Patient Satisfaction Between Two Diffractive Trifocal Intraocular Lenses
|
||
Completed |
NCT04255706 -
Repeatability in Measurements of Two ssOCT and One OLCR Biometer
|
N/A | |
Completed |
NCT05287269 -
Ocular Coherence Tomography During Cataract Assessment
|
||
Completed |
NCT04545671 -
Evaluation of a Trifocal Lens
|
||
Completed |
NCT04580550 -
Axial Length Variability
|
N/A | |
Recruiting |
NCT04265846 -
Prospective Clinical Study of Different Intraocular Lens Implantation Designed for the Correction of Presbyopia
|
||
Not yet recruiting |
NCT06429527 -
Vision Test App and Questionnaire for 1-Week Post-Cataract Surgery Follow-Up: A Multi-Center Randomized Controlled Trial
|
N/A | |
Completed |
NCT03970525 -
Venturi and Peristaltic Based Phacoemulsification in Femtosecond Laser Cataract Surgery
|
||
Completed |
NCT05578339 -
Predicting the Lens Capsular Bag Size Using Pre-operative Biometry
|
N/A |