View clinical trials related to Cardiac Output, Low.
Filter by:A single-center feasibility study in patients undergoing cardiac catheterization, to investigate the acute hemodynamic effects of transvenous cardiac autonomic nerve stimulation.
Changes in volumetric hemodynamic parameters and fluid overload (Cardiac Index,Stroke Volume, Thoracic Fluid Content, Systemic Vascular Resistance) were measured using a impedance cardiography (ICG) (CardioScreen 1000 - Haemodynamic Measurement System, Medis. Ilmenau) in stable renal transplant recipients Nutritional status was measured by Tanita 418 Monitor.
Monitoring the bispectral index (BIS) as a peri-operative hemodynamic tool appears to be justified by the agreement between various clinical situations in which BIS monitoring appears to be of value: the prognosis in traumatic head injury, the diagnosis of brain death , and the diagnosis of amniotic fluid embolism. The current controversy concerning the "triple low" state reinforces the need for an accurate study in this field. Furthermore, the recent review by Bidd argues in this sense.
This is a retrospective observational study to assess the relationship between peak systolic global longitudinal strain measured on pre-cardiopulmonary bypass trans-esophageal echo images predicts post-operative low cardiac output syndrome defined as the need for an inotropic support during 24 hours or longer.
Obesity has become one of the most common risk factors in obstetric practice with serious anaesthetic implications. Obese pregnants have limited physiological reserves and cardiovascular co- morbidities when compared to non-obese pregnant women. Spinal anaesthesia is the anaesthetic technique of choice for caesarean section. The haemodynamic changes associated with spinal anaesthesia pose the greatest hazard to the mother and the foetus and are exaggerated in obese pregnant women. However differences in the changes in haemodynamic variables such as cardiac output (CO), stroke volume (SV) and systemic vascular resistance (SVR) between obese and non-obese pregnant women having caesarean section (CS) under spinal anaesthesia have not been studied before. This study compares the haemodynamic changes after spinal anaesthesia for CS in non-obese and obese parturients in a single centre, prospective case control study, using LiDCOrapidV2. This LiDCOrapidV2 device is a noninvasive method of measuring haemodynamic variables. It is a single centre, prospective, case control study. The primary outcome compares the differences and variability in CO, SV and SVR between obese and non-obese parturients. The secondary outcomes include comparison of the correlation between changes in blood pressure (BP) and CO in each patient and the difference in BP between conventional intermittent oscillometric device and continuous LiDCORapidV2in each patient with a view to assess the need for measurement of cardiac output in obstetric anaesthesia
The purpose of this study is to find out the Lidco Rapid ( monitoring tool gives cardiac output) is as equivalent in determining the hemodynamic assessment in cardiac surgical scenarios as the most often used pulmonary artery catheter, which is much more invasive than the Lidco Rapid. This will be accomplished through online surveys which have different cardiac surgery scenarios and will be distributed to cardiac fellowship trained anesthesiologists. The online based survey will include a specific scenario and details on the scenario represented in image format and a brief description of the patient to aid with their analysis of the situation.
Measurement of the cardiac output is one of the important hemodynamic monitoring tools in cardiac surgery. It helps determine the type of medications needed to maintain optimal hemodynamic status in the entire perioperative period. Thermodilution method using pulmonary artery catheter is considered has the gold standard for the measurement of cardiac output. Investigators would like to compare the most popular minimally-invasive devices used to measure cardiac output using arterial waveform: LiDCO Rapid and TEE with the thermodilution method at various phases of the cardiac surgery.
Changes in volumetric hemodynamic parameters and fluid overload (Cardiac Index,Stroke Volume, Thoracic Fluid Content, Systemic Vascular Resistance) were measured using a impedance cardiography (ICG) (CardioScreen 1000 - Haemodynamic Measurement System, Medis. GmbH Ilmenau) beginning 15 min prior to midweek dialysis session and continuous measurement thereafter, with a 15-min period after the termination of hemodialysis. Fluid overload were measured by BCM Monitor Fresenius before hemodialysis.
This study assesses the 18-month incidence of inappropriate shocks in subjects implanted with the EMBLEM Subcutaneous Implantable Defibrillator (S-ICD) for primary prevention of sudden cardiac death. Devices are to be programmed with zone cutoffs at 200 bpm and 250 bmp in order to mimic the programming settings for transvenous ICDs in the MADIT RIT study. The incidence of inappropriate S-ICD shocks will be compared to the incidence of inappropriate shocks observed in the MADIT RIT study.
Inotropic agents are usually administered in the postoperative period after cardiac surgery. In most cases, dobutamine is administered routinely, for the probable occurrence of myocardial dysfunction after cardiopulmonary bypass or a low cardiac output with minimal evidence of altered tissue perfusion. Recent data show that inotropic agents are used in 35-52% of cardiac surgeries in the perioperative period. However, the use of inotropic agents may be associated with adverse events, including myocardial ischemia, by elevation in myocardial oxygen consumption and the imbalance between supply and consumption, and tachyarrhythmias (atrial fibrillation, sinus tachycardia, ventricular tachyarrhythmias), primarily due to the β1-adrenergic effect. This study is a non-inferiority clinical randomized study aiming to compare the use of dobutamine in a liberal strategy (in all patients at the time of withdrawal of CPB) with a restrictive strategy (based on clinical and hemodynamic evidence of low cardiac output syndrome associated with altered tissue perfusion). Our primary hypothesis is that the restrictive use of dobutamine is as safe and effective as the liberal one.