Ventricular Tachycardia Clinical Trial
Official title:
Understanding Outcomes With the EMBLEM™ S-ICD in Primary Prevention Patients With Low Ejection Fraction
This study assesses the 18-month incidence of inappropriate shocks in subjects implanted with the EMBLEM Subcutaneous Implantable Defibrillator (S-ICD) for primary prevention of sudden cardiac death. Devices are to be programmed with zone cutoffs at 200 bpm and 250 bmp in order to mimic the programming settings for transvenous ICDs in the MADIT RIT study. The incidence of inappropriate S-ICD shocks will be compared to the incidence of inappropriate shocks observed in the MADIT RIT study.
Implantable cardioverter defibrillator (ICD) therapy is highly effective for reducing mortality in patients with clinical markers for elevated risk for ventricular arrhythmias. However, inappropriate shocks and unnecessary appropriate shocks remain an important side effect that can significantly affect an ICD recipient's quality of life and may be deleterious to the myocardium. The MADIT RIT study demonstrated that the incidence of inappropriate and unnecessary appropriate ICD therapy can be reduced in primary prevention patients through two different programming strategies: 1) High Rate Zone Cutoff, i.e., raising the lowest rate detection cutoff to 200 bpm; and 2) Delayed Therapy Initiation, i.e., increasing the time to therapy initiation to 60 seconds for arrhythmias detected between 170-199 bpm and 12.5 seconds between 200-249 bpm. Both strategies effectively reduced the amount of ICD therapy delivered when compared to conventional programming, where the lowest rate detection cutoff was 170 bpm and the delay to therapy initiation was programmed to 2.5 seconds. Importantly, neither treatment arm was associated with significantly increased syncope or mortality. The results of MADIT RIT established preferred device settings for reducing shocks in transvenous ICD (TV-ICD) patients with a primary prevention indication. Preferred settings for subcutaneous ICDs, however, have not been established with data from prospective studies. The UNTOUCHED study will test a programming scheme designed to minimize inappropriate and unnecessary shocks in patients who have an indication for primary prevention of sudden cardiac death and low ejection fraction. Although S-ICD programming options do not permit exact replication of the programmed settings previously shown to reduce shocks in the MADIT RIT treatment arms, key elements are combined into the UNTOUCHED settings to be tested in this protocol. It is hypothesized that despite the lack of anti-tachycardia pacing, the EMBLEM S-ICD settings utilized in this study will result in an overall shock incidence similar to that observed in ICD patients from MADIT RIT. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT03453645 -
Modification of Rhythmic Risk Assessment by Ventricular Tachycardia Ablation
|
||
Completed |
NCT05970120 -
A Study of Intracardiac Ultrasound With the NUVISION NAV Ultrasound Catheter
|
N/A | |
Completed |
NCT05791032 -
Sub Chronic Evaluation for ATP With an Extravascular Placed ICD Lead (STEP ICD) Study
|
N/A | |
Completed |
NCT04011631 -
Evaluation of the iD-SystemTM, One-Handed Disposable Internal Defibrillation System.
|
N/A | |
Recruiting |
NCT03536052 -
Ablation at Virtual-hEart pRedicted Targets for VT
|
N/A | |
Not yet recruiting |
NCT06063811 -
Ventricular Tachycardia Ablation in LVAD Patients
|
||
Enrolling by invitation |
NCT02962076 -
Study of Cardiac PET/CT Imaging to Guide Ablation Treatment of Ventricular Tachycardia
|
Early Phase 1 | |
Not yet recruiting |
NCT02784912 -
Biomarkers in Risk Stratification of Sustainted Ventricular Tachycardia or Electrical Storm After Ablation
|
N/A | |
Completed |
NCT01791543 -
Intramural Needle Ablation for Ablation of Recurrent Ventricular Tachycardia
|
N/A | |
Terminated |
NCT02891863 -
Low Energy Therapy to Convert Ventricular Tachycardias
|
Phase 0 | |
Terminated |
NCT01546207 -
Stepwise Approach To sUbstrate Modification for Ventricular Tachycardia
|
N/A | |
Completed |
NCT01294267 -
Percutaneous Hemodynamic Support With Impella 2.5 During Scar-related Ventricular Tachycardia Ablation
|
N/A | |
Terminated |
NCT00383799 -
Iv Amiodarone Versus Iv Procainamide to Treat Haemodynamically Well Tolerated Ventricular Tachycardia
|
Phase 4 | |
Completed |
NCT04884100 -
enHEART - Exploring Full Content of Optical Signals to Enhance Cardiac Arrhythmia Screening
|
N/A | |
Completed |
NCT04642963 -
Stereotactic Management of Arrhythmia - Radiosurgery in Treatment of Ventricular Tachycardia
|
N/A | |
Recruiting |
NCT05377216 -
Characterization of Cardiac Electrophysiological Effects of Autonomic Neuromodulation
|
Early Phase 1 | |
Not yet recruiting |
NCT04990089 -
VIVO European Observational Registry
|
||
Completed |
NCT04065893 -
Impact of Catheter Ablation of Ventricular Arrhythmias on Suboptimal Biventricular Pacing in Cardiac Resynchronization Therapy
|
||
Recruiting |
NCT03631303 -
Post-Extrasystolic Potentiation as a Predictor of Ventricular Arrhythmias
|
||
Recruiting |
NCT03611465 -
Creation of a Pace-mapping Atlas on Healthy and Pathological Hearts
|
N/A |