Clinical Trials Logo

Clinical Trial Summary

Rationale: Breast cancer patients are increasingly treated with neoadjuvant chemotherapy for various reasons. These women receive chemotherapy before any surgery is performed. Many of these tumors need preoperative seed localization to help guide the surgeons to the site of the tumor within the breast. The interest is shifting towards to use of non-radioactive seeds, such as the magnetic seeds used in this study. A drawback of these seeds is the fact that they cause large susceptibility artifacts on (magnetic!) MRI of the breast. Breast MRI is the most accurate modality to monitor response to therapy of these women. CEM, an emerging breast imaging technique, has shown to achieve comparable results with regard to response monitoring but uses no magnetic fields. Hence, CEM might be an attractive alternative response monitoring tool in patients treated with neoadjuvant chemotherapy and having a magnetic seed a surgical marker. To this point, however, no study in humans has confirmed that this is indeed the case. Objective: To test whether the use of magnetic localization seeds causes image artifacts on CEM. Study design: Observational feasibility study. Study population: Women (>18 years) able to provide written informed consent and recently diagnosed with (non-palpable) breast cancer or ductal carcinoma in situ (DCIS), who are primarily treated with surgery. Intervention (if applicable): Image-guided placement of a magnetic seed (Sirius Pintuition) prior to surgery, including control imaging to confirm the correct location of the seed relative to the breast abnormality. In usual patient care this is performed with full-field digital mammography (FFDM), but in this study this control image will be performed with the system in 'contrast-enhanced mammography' or CEM mode, but without using intravenous administration of iodinated contrast agent because the purpose is not repetition of diagnostic imaging, but to rule out any artifacts caused by the seed on CEM. The investigators estimate to include twenty patients to confidently test the hypothesis that magnetic seeds do not cause disturbing artifacts on CEM examinations. Main study parameters/endpoints: The primary study aim will be to test whether the magnetic seeds caused any disturbing artifacts on CEM images. As secondary study, the investigators will document technical success rate of seed deployment and retrieval during surgery, including the assessment of the surgical margins (positive or negative).


Clinical Trial Description

Rationale: Breast cancer patients are increasingly treated with neoadjuvant chemotherapy for various reasons. These women receive chemotherapy before any surgery is performed. Many of these tumors need preoperative seed localization to help guide the surgeons to the site of the tumor within the breast. In many hospitals, a radioactive I-125 seed is used for this purpose, which has several disadvantages, such as a slight increase in radiation dose and extensive administrative regulations to monitor the location of the seed at any time (required by law). This administrative work is time consuming, elaborate and prone to errors. Therefore, interest is shifting towards to use of non-radioactive seeds, such as the magnetic seeds used in this study. A drawback of these seeds is the fact that they cause large susceptibility artifacts on (magnetic!) MRI of the breast. Breast MRI is the most accurate modality to monitor response to therapy of these women. CEM, an emerging breast imaging technique, has shown to achieve comparable results with regard to response monitoring but uses no magnetic fields. Hence, CEM might be an attractive alternative response monitoring tool in patients treated with neoadjuvant chemotherapy and having a magnetic seed a surgical marker. To this point, however, no study in humans has confirmed that this is indeed the case. Objective: To test whether the use of magnetic localization seeds causes image artifacts on CEM. Study design: Observational feasibility study. Study population: Women (>18 years) able to provide written informed consent and recently diagnosed with (non-palpable) breast cancer or ductal carcinoma in situ (DCIS), who are primarily treated with surgery. Intervention (if applicable): Image-guided placement of a magnetic seed (Sirius Pintuition) prior to surgery, including control imaging to confirm the correct location of the seed relative to the breast abnormality. In usual patient care this is performed with full-field digital mammography (FFDM), but in this study this control image will be performed with the system in 'contrast-enhanced mammography' or CEM mode, but without using intravenous administration of iodinated contrast agent because the purpose is not repetition of diagnostic imaging, but to rule out any artifacts caused by the seed on CEM. The investigators estimate to include twenty patients to confidently test the hypothesis that magnetic seeds do not cause disturbing artifacts on CEM examinations. Main study parameters/endpoints: The primary study aim will be to test whether the magnetic seeds caused any disturbing artifacts on CEM images. For this purpose, two radiologists will score the images for the presence of any artifacts and if present, if these are to such an extent that they would hamper diagnostic evaluation of the images. The radiologists will assess the images independently first, and consensus opinion is formed should any discrepancies occur in their judgement. As secondary study, the investigators will document technical success rate of seed deployment and retrieval during surgery, including the assessment of the surgical margins (positive or negative). Nature and extent of the burden and risks associated with participation, benefit, and group relatedness: The burden and risk for participating subjects are very small. In regular care, a radioactive I-125 seed is placed in the breasts of these women, checking the position with (conventional) FFDM. For this purpose, the iodine seed is replaced with a (radioactive-free) magnetic seed (Sirius Pintuition). The latter did not show any relevant imaging artifacts prior to this study in imaging phantoms (i.e., chicken breasts containing magnetic seeds). Therefore, the investigators feel confident that these seeds will not show artifacts on clinical CEM image, but this needs to be confirmed before additional studies regarding the clinical application of CEM and magnetic seeds combined can be safely performed. The only additional disadvantage for participants is the slight increased radiation dose of the (extra) high-energy image CEM image, which is an increased radiation dose to the breasts of 50-80%. However, these women are all diagnosed with breast cancer requiring adjuvant radiotherapy, which uses radiation doses much, much higher than a single mammographic exposure. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06049446
Study type Observational [Patient Registry]
Source Zuyderland Medisch Centrum
Contact
Status Completed
Phase
Start date September 8, 2023
Completion date June 10, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT04681911 - Inetetamab Combined With Pyrotinib and Chemotherapy in the Treatment of HER2 Positive Metastatic Breast Cancer Phase 2
Completed NCT04890327 - Web-based Family History Tool N/A
Terminated NCT04066790 - Pyrotinib or Trastuzumab Plus Nab-paclitaxel as Neoadjuvant Therapy in HER2-positive Breast Cancer Phase 2
Completed NCT03591848 - Pilot Study of a Web-based Decision Aid for Young Women With Breast Cancer, During the Proposal for Preservation of Fertility N/A
Recruiting NCT03954197 - Evaluation of Priming Before in Vitro Maturation for Fertility Preservation in Breast Cancer Patients N/A
Terminated NCT02202746 - A Study to Assess the Safety and Efficacy of the VEGFR-FGFR-PDGFR Inhibitor, Lucitanib, Given to Patients With Metastatic Breast Cancer Phase 2
Active, not recruiting NCT01472094 - The Hurria Older PatiEnts (HOPE) With Breast Cancer Study
Withdrawn NCT06057636 - Hypnosis for Pain in Black Women With Advanced Breast Cancer: A Feasibility Study N/A
Recruiting NCT05560334 - A Single-Arm, Open, Exploratory Clinical Study of Pemigatinib in the Treatment of HER2-negative Advanced Breast Cancer Patients With FGFR Alterations Phase 2
Active, not recruiting NCT05501769 - ARV-471 in Combination With Everolimus for the Treatment of Advanced or Metastatic ER+, HER2- Breast Cancer Phase 1
Recruiting NCT04631835 - Phase I Study of the HS-10352 in Patients With Advanced Breast Cancer Phase 1
Completed NCT04307407 - Exercise in Breast Cancer Survivors N/A
Recruiting NCT03544762 - Correlation of 16α-[18F]Fluoro-17β-estradiol PET Imaging With ESR1 Mutation Phase 3
Terminated NCT02482389 - Study of Preoperative Boost Radiotherapy N/A
Enrolling by invitation NCT00068003 - Harvesting Cells for Experimental Cancer Treatments
Completed NCT00226967 - Stress, Diurnal Cortisol, and Breast Cancer Survival
Recruiting NCT06037954 - A Study of Mental Health Care in People With Cancer N/A
Recruiting NCT06006390 - CEA Targeting Chimeric Antigen Receptor T Lymphocytes (CAR-T) in the Treatment of CEA Positive Advanced Solid Tumors Phase 1/Phase 2
Recruiting NCT06019325 - Rhomboid Intercostal Plane Block on Chronic Pain Incidence and Acute Pain Scores After Mastectomy N/A
Recruiting NCT05622240 - 99mTc-MIRC213 SPECT/CT for the Detection of HER2-positive Breast Cancer Early Phase 1