View clinical trials related to Aortic Aneurysm, Thoracic.
Filter by:The goal of this observational study is to evaluate the Thoraflex Hybrid device alone and in combination with the RelayPro NBS stent-graft in the treatment of aortic disease affecting the aortic arch and descending aorta with or without involvement of the ascending aorta. Patients who undergo treatment with the Thoraflex Hybrid device with or without extension with a RelayPro NBS stent-graft will be eligible for enrolment and study activities and follow-up regime will follow standard care at each participating site. Participant involvement in the study will last for a total of 10 years from the point at which the Thoraflex Hybrid device is placed.
Post Marketing Surveillance of the Conformable GORE® TAG® Thoracic Endoprosthesis
The infection rate of thoracic endovascular aortic repair (TEVAR) is unknown due to a lack of epidemiological data. The rate currently available comes from researches conducted decades ago, when open surgery was the standard of care. Because of the potentially fatal consequences of a stent graft infection in the thoracic aorta, the investigators tend to prescribe antibiotic prophylaxis for at least three days. In this study, the investigators are going to collect data on patients receiving TEVAR in the past five years and provide the following information: a. the infection rate (MAGIC classification), b. the rate of fever, c. the results of the lab tests, such as the WBC count and C-reaction protein. d. risk factors associated with infection and fever.
Thoracic aneurysm is a silent disease with a potential mid-term high risk of death or major complications. Few data are available on the real incidence of major complications in case of small and moderate thoracic aneurysm. Different factors are supposed to increase the risk of aortic enlargement as high blood pressure and sleep disorder breathing. The modality of imaging and clinical follow-up are well defined. In this prospective observational study, the aim to assess the incidence of of major complications during follow-up in a population of patients with a small or moderate thoracic aneurysm. The study will also try to identify systemic factors influencing aneurysm evolution.
The aorta is the principal arterial vessel arising from the left heart that transfers blood to the body. Certain genetic and familial disease processes are known to weaken the aortic wall resulting in dilation and potential rupture. These aortic complications carry high mortality (>25%) and current management is orientated towards early detection and preventive treatment. Aortic dilation can also result in aortic valve dysfunction leading to heart failure. The estimated UK incidence of aortic disease per year is around 10 per 100,000 individuals, with 2000 people per year dying from aortic complications. The 2017-2020 National Adult Cardiac Surgery Audit report identified the number of people receiving surgery for aortic dissection in Scotland is per population proportionately lower compared to England (4.6 per million per year in Scotland vs. 6.6 per million per year in England). The reasons for this are unclear but may relate to the prevalence of aortic disease or a large geographic distribution with compromised access to specialized centres. Currently surgery is recommended when the aortic diameter exceeds a certain threshold. There are several types of effective surgical procedures, but there is still limited information on their long-term outcomes and the advantage of one procedure over another. The aims of the project are firstly to determine the clinical outcomes of the surgical procedures that are currently employed in Scotland to treat proximal aortic disease and secondly to describe the prevalence and distribution of proximal aortic disease within the Scottish population. The project will be hosted by the Golden Jubilee Research Institute. Contemporary and retrospective data will be collected from all the Scottish Cardiothoracic Surgery units which are based in Glasgow, Edinburgh and Aberdeen. This will be the first study to analyse surgical outcomes for ascending aortic disease in Scotland, and the first to describe the epidemiology of aortic disease within the population. It is anticipated that the results will guide current surgical practise, and provide data to inform national service provision for the management of proximal aortic disease.
The physician modified endograft is intended for treating complex, pararenal, juxtarenal and thoracoabdominal aortic aneurysms requiring coverage of renal arteries, the superior mesenteric artery or the celiac trunk in high-risk patients who do not have an option for endovascular repair with an FDA approved endograft and have an appropriate anatomy. There will be one investigational site with a total of 40 subjects to be enrolled. Time to complete enrollment will be 24 months and the subject follow-up time will be five years from last subject enrollment. The primary safety endpoint is freedom from major adverse events (MAE) at 30 days or during hospitalization if this exceeds 30 days. The primary effectiveness endpoint is the proportion of study subjects with treatment success at one year. The subjects will be followed at one month, six months, one year, and yearly thereafter for a total period of five years. Subjects will be followed up clinically for life. Clinical exam follow up may be phone or video visit with CT scan evaluation and duplex ultrasound as needed. The proportion of treatment group subjects that achieve and maintain treatment success annually to five years will be investigated.
The ENDOBARC-S post-market clinical follow-up study is undertaken to evaluate the prevention of death related to aortic arch pathologies when treated by branch stent graft systems (Nexus stent-graft system®, Relay Branch® or Zenith arch branch graft®), with proximal landing at zone 0. The secondary objective is to evaluate the safety and clinical performance of the studied devices.
The purpose of the registry is to compare the surgical and endovascular approaches to the treatment of thoracoabdominal aortic aneurysms.
Advanced Endovascular repair of aneurysms and dissections involving thoraco-abdominal (type I-IV) and complex abdominal (juxta and para-renal) aorta is a ground-gaining procedure allowing favorable results in high surgical risk patients. The availability of iliac vessels navigation and the major role of lower leg perfusion in order to decrease the risk of spinal cord ischemia during these complex procedures, led to the development of devices with lower sheaths sizes and to the improvement of the technique with preloaded devices for visceral vessels in order to navigate in hostile anatomies or when an iliac access is not available. The aim of the study is to evaluate in a prospective single center observational setting, the outcomes, safety and efficacy of the modified preloaded system for renal arteries in fenestrated endografting in the routine treatment of paravisceral and thoraco-abdominal aortic pathologies.
The primary objective is to evaluate the safety and effectiveness of surgeon modified endografts for the treatment of pararenal and thoracoabdominal aortic pathology in patients who are not candidate for traditional open repair due to comorbid issues and their anatomy is not amenable to commercially available endografts.