View clinical trials related to Aortic Aneurysm, Thoracic.
Filter by:The goal of the prospective observational study is to evaluate the immunological background of inflammatory response often seen after open thoracic aortic surgery. Patients scheduled for this type of procedure will undergo a series of blood testing (preoperatively, and several times postoperatively). The blood samples will be used for a wide scale of immunological tests to better evaluate potential differential markers against infection. A control group will include patients with active infective endocarditis (preoperatively). The main question is if there is a biomarker able to determine a difference between sterile systemic inflammation and infection after thoracic aortic surgery. The second question is if there is a difference in dynamics of evaluated biomarkers between sterile postoperative inflammation and active endocarditis.
Ruptured thoracoabdominal aortic aneurysm (TAAA) represents an emergency medical challenge that needs to be treated promptly. Over the past years different endovascular techniques have emerged such as fenestrated or branched endovascular aortic repair (FB-EVAR). However, FB-EVAR is a technique that uses a custom-made device which needs to be manufactured and this process take months, therefore, it could not be used in urgent settings. Off-the-shelf graft stents are pre-made graft stents, which can be used in urgent cases. A retrospective, multicenter cohort study was planned to include patients who underwent endovascular procedures between January 2015 and January 2022 (85 months) to evaluate the technical and survival outcomes of the use of off-the-shelf stent graft, physician-modified endograft and parallel graft technique in endovascular aortic repair of free and contained ruptured TAAA. Data will be collected anonymously and retrospectively, including patient demographics, risk factors, diagnosis and anatomical details, procedure details and post-operative outcomes.
The INNER-B-APAC post-market clinical follow-up study is undertaken to demonstrate the safety and clinical performance of the E-nside TAAA Multibranch Stent Graft System used in endovascular treatment of patients with thoracoabdominal aortic aneurysms.
The primary objective of ARISE II is to assess the safety and effectiveness of the GORE® Ascending Stent Graft device in the treatment of lesions involving the ascending aorta and aortic arch.
This study aims to evaluate mid- and long-term outcomes after Thoracic endovascular aortic repair (TEVAR) with custom-made devices.
To assess safety and feasebility of the "safe-line" technique in a multicenter international collaboration.
The goal of this observational cross-sectional study is to learn about vagal features in patients with syndromic and non-syndromic TAA. The main question it aims to answer is to highlight a functional condition that could help stratify patients with TAA on the risk of aortic complications. Participant will take part by standing in supine position for 10 minutes and during active standing for 10 minutes. In this period of time, it will be possible to acquire the signals continuously and non invasively through recorded non-invasive blood pressure and piezoelectric sensor breathing belt.
Rationale: Aortic diameter is currently used as a gold standard in international guidelines for prediction of aorta pathology (aortic aneurysm and aortic dissection). However, aortic diameter has proven to be insufficiently accurate for making decisions about well-timed preventive interventions. The LANDMARC study will take place in line with the FIBAA-bank ('Correlatie tussen cardiovasculaire FIBroseringsgraad en Aorta elongatie, dilatatie en Atria dilatatie (FIBAA-bank): een biobank & databank onderzoek met focus op aorta en atria' (METC-number 2022-3164)), and aims to reveal the undiscovered relationship between WSS (wall shear stress) values and aortic strain. In combination with data from the FIBAA-bank, the LANDMARC study will provide more accurate information for future risk stratification models for cardiovascular pathology (with focus on aortic disease). Objectives: Primary objective: indication of the association between WSS (peak WSS and WSS gradient) (through 4D-flow MR and CT) and aortic strain. Secondary objective: indication of the association between (hemo)dynamic processes within the body (aortic elongation/aortic strain) and (patho-)physiological changes (degree of cardiovascular tissue fibrosis).
Thoracic aortic aneurysms (TAA) result from progressive dilatation of the thoracic aorta and confer a risk for aortic dissection or rupture, which is associated with significant morbidity and mortality. In the Netherlands there are an estimated 200.000 adults with TAA, and annually 600 deaths after aortic dissection or rupture. There are clear differences in the incidence of TAA between men and women, with a higher incidence in men. Little is known on possible differences in outcome between male and female patients with Thoracic Aortic Aneurysm (TAA). Aortic disease is thought to affect men more frequently than women, and aortic growth is different between men and women. Current data suggest that women are at an increased risk of both dying from aortic dissection and having aorta-related complications compared to men (1). The mechanisms for these male-female difference in TAA outcome remain, however, unclear. The timing of preventive surgery is now not different for men and women, but gender-based cut-off values for maximal aortic diameter based on differences in vessel wall composition might be needed.
The purpose of this study is to collect clinical data on patient outcomes, evaluate the safety and performance of Ankura TAA Stent Graft System and Surpass Super Stiff Guidewire, and build clinical evidence for patients with Descending Thoracic Aneurysm (DTA) or Type B Aortic Dissection (TBAD).