Acute Respiratory Failure Clinical Trial
Official title:
Low-Flow (LF) Oxygen Versus Heated Humidified High-Flow (HF) Therapy Following Tracheostomy
Respiratory failure patients sometimes receive tracheostomy due to difficulty weaning from mechanical ventilation. Efforts to wean patients with a tracheostomy usually involve the administration of oxygen via High Humidity device. There are two major ways of administering oxygen to patients which include low flow delivered at less than 10Liters per minute (LPM) and high-flow delivered at greater than 10LPM. There is not a currently accepted standard of care practice for how to administer oxygen therapy to these patients. Both Low and High Flow are accepted practices in the US.
Many patients with Respiratory Failure undergo tracheostomy due to difficulty weaning from mechanical ventilation. A component of weaning a patient with tracheostomy usually involves the administration of oxygen via High Humidity device. There are two major ways of administering oxygen via High Humidity to patients. They include low flow high humidity; delivered at less than or equal to 10LPM or high-flow humidity, delivered at greater than 10LPM. There is not a currently accepted standard of practice for how to administer oxygen high humidity to patients who receive a tracheostomy due to respiratory failure. Both Low and High Flow high humidity devices are used routinely by health care facilities nationwide. Therefore, the investigators plan to perform a crossover study in both a medicine and surgical Intensive Care Unit to determine which type of oxygen High Humidity therapy should be preferentially utilized. Patients in one Intensive Care Unit will start off with Low Flow high humidity while the alternate unit will start with Hi Flow high humidity. After one half of the required sample size is accrued the investigators will cross over the two ICUs to the alternate type of oxygen High Humidity device. No other respiratory practices will change during the conduct of this trial. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05144633 -
Blue Protocol and Eko Artificial Intelligence Are Best (BEA-BEST)
|
||
Completed |
NCT04534569 -
Expert Panel Statement for the Respiratory Management of COVID-19 Related Acute Respiratory Failure (C-ARF)
|
||
Recruiting |
NCT03021902 -
Nutrition and Exercise in Critical Illness
|
Phase 2 | |
Completed |
NCT02902146 -
Bougie Use in Emergency Airway Management
|
N/A | |
Completed |
NCT02901158 -
Esophageal Manometry in Mechanically Ventilated Patients
|
||
Completed |
NCT02236559 -
High Flow Therapy for the Treatment of Respiratory Failure in the ED
|
N/A | |
Recruiting |
NCT02056093 -
Comparison of Proportional Assist Ventilation And Neurally Adjusted Ventilator Assist
|
N/A | |
Not yet recruiting |
NCT01668368 -
Goal Directed Mechanical Ventilation Aimed at Optimal Lung Compliance
|
N/A | |
Terminated |
NCT01083277 -
Variable Ventilation During Acute Respiratory Failure
|
N/A | |
Completed |
NCT01462279 -
Effect of Thiamine on Oxygen Utilization (VO2) in Critical Illness
|
N/A | |
Completed |
NCT01114022 -
Prevention Inhalation of Bacterial by Using Endotracheal Tube Balloon Polyvinyl Chloride or Polyurethane
|
N/A | |
Active, not recruiting |
NCT01058421 -
Treatment of Critical Illness Polyneuromyopathy
|
Phase 2 | |
Completed |
NCT00252616 -
Timing of Target Enteral Feeding in the Mechanically Ventilated Patient
|
Phase 2/Phase 3 | |
Recruiting |
NCT04098094 -
Outcomes of RV Dysfunction in Acute Exacerbation of Chronic Respiratory Diseases
|
||
Recruiting |
NCT06051292 -
Decremental Esophageal Catheter Filling Volume Titration For Transpulmonary Pressure Measurement
|
N/A | |
Completed |
NCT04601090 -
Survival Rates and Longterm Outcomes After COVID-19
|
||
Recruiting |
NCT05423301 -
Global Physiotherapy in ICU Patients With High Risk Extubation Failure
|
N/A | |
Completed |
NCT02447692 -
Proportional Assist Ventilation for Minimizing the Duration of Mechanical Ventilation: The PROMIZING Study
|
N/A | |
Completed |
NCT04016480 -
HFNC During Bronchoscopy for Bronchoalveolar Lavage
|
N/A | |
Completed |
NCT04507425 -
High Flow Nasal Cannula With Noninvasive Ventilation
|
N/A |