Acute Respiratory Distress Syndrome Clinical Trial
Official title:
Closed-loop syncHronization vErsuS convenTional Synchronization in sPontaneously Breathing Adult Nonivasive Ventilation Patients (CHEST-SPAN) - a Randomized Cross-over Trial
The study is a multicentric prospective randomised cross-over study. It evaluates the compatibility of patients with the device without altering the routine treatment applied. During this evaluation, either the clinician-adjusted values on the device or the standard pre-set values are used to obtain hourly and 30-minute PVA (Patient Ventilator Asynchrony) recordings. These recordings will be analysed offline to identify the settings used and to compare the hourly and 30-minute PVA (Patient Ventilator Asynchrony) values when synchronisation is automatically set. The relationships and differences between these values will be analysed. For this purpose, the IntelliSync+ option, already available on the device, will be used. This software continuously analyses waveform signals at least a hundred times per second. This allows for the immediate detection of patient efforts and the initiation of inspiration and expiration in real time, thereby replacing traditional trigger settings for inspiration and expiration. If the patient is already synchronised with this option, it will then be possible to switch to traditional synchronisation settings for comparison. Statistical analyses will be conducted using SPSS 24.0, JASP (Just Another Statistical Programme), Jamovi ( fork of JASP), or R software. Initially, all numerical and categorical data will be evaluated using descriptive statistical methods. The distributions of numerical variables will be examined using visual (histograms and probability plots) and analytical methods (Kolmogorov-Smirnov/Shapiro-Wilk tests). Mean/SD (standard deviation) or median/interquartile range (IQR) will be used as measures of distribution. For comparing numerical data that follows a normal distribution, the Student-t test will be used, and for non-normally distributed data, the Mann-Whitney U or Wilcoxon signed-rank tests will be employed. PVA (Patient Ventilator Asynchrony) values will be statistically compared. For the analysis of categorical data, the Chi-Square test will be applied. Bayesian analysis may also be used as necessary during the writing of the study. The results obtained will be interpreted and reported by the researchers. Results with a "p" value below 0.05 will be considered statistically significant.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04384445 -
Zofin (Organicell Flow) for Patients With COVID-19
|
Phase 1/Phase 2 | |
Recruiting |
NCT05535543 -
Change in the Phase III Slope of the Volumetric Capnography by Prone Positioning in Acute Respiratory Distress Syndrome
|
||
Completed |
NCT04695392 -
Restore Resilience in Critically Ill Children
|
N/A | |
Terminated |
NCT04972318 -
Two Different Ventilatory Strategies in Acute Respiratory Distress Syndrome Due to Community-acquired Pneumonia
|
N/A | |
Completed |
NCT04534569 -
Expert Panel Statement for the Respiratory Management of COVID-19 Related Acute Respiratory Failure (C-ARF)
|
||
Completed |
NCT04078984 -
Driving Pressure as a Predictor of Mechanical Ventilation Weaning Time on Post-ARDS Patients in Pressure Support Ventilation.
|
||
Completed |
NCT04451291 -
Study of Decidual Stromal Cells to Treat COVID-19 Respiratory Failure
|
N/A | |
Not yet recruiting |
NCT06254313 -
The Role of Cxcr4Hi neutrOPhils in InflueNza
|
||
Not yet recruiting |
NCT04798716 -
The Use of Exosomes for the Treatment of Acute Respiratory Distress Syndrome or Novel Coronavirus Pneumonia Caused by COVID-19
|
Phase 1/Phase 2 | |
Withdrawn |
NCT04909879 -
Study of Allogeneic Adipose-Derived Mesenchymal Stem Cells for Non-COVID-19 Acute Respiratory Distress Syndrome
|
Phase 2 | |
Not yet recruiting |
NCT02881385 -
Effects on Respiratory Patterns and Patient-ventilator Synchrony Using Pressure Support Ventilation
|
N/A | |
Terminated |
NCT02867228 -
Noninvasive Estimation of Work of Breathing
|
N/A | |
Completed |
NCT02545621 -
A Role for RAGE/TXNIP/Inflammasome Axis in Alveolar Macrophage Activation During ARDS (RIAMA): a Proof-of-concept Clinical Study
|
||
Completed |
NCT02232841 -
Electrical Impedance Imaging of Patients on Mechanical Ventilation
|
N/A | |
Withdrawn |
NCT02253667 -
Palliative Use of High-flow Oxygen Nasal Cannula in End-of-life Lung Disease Patients
|
N/A | |
Completed |
NCT01504893 -
Very Low Tidal Volume vs Conventional Ventilatory Strategy for One-lung Ventilation in Thoracic Anesthesia
|
N/A | |
Completed |
NCT02889770 -
Dead Space Monitoring With Volumetric Capnography in ARDS Patients
|
N/A | |
Withdrawn |
NCT01927237 -
Pulmonary Vascular Effects of Respiratory Rate & Carbon Dioxide
|
N/A | |
Completed |
NCT02814994 -
Respiratory System Compliance Guided VT in Moderate to Severe ARDS Patients
|
N/A | |
Completed |
NCT01680783 -
Non-Invasive Ventilation Via a Helmet Device for Patients Respiratory Failure
|
N/A |