Clinical Trials Logo

Clinical Trial Summary

Mechanical power (MP) and ventilatory ratio (VR) are variables associated with outcomes in patients with acute respiratory distress syndrome (ARDS). In respiratory setting, the optimization of MP should lead to an increase in VR. Therefore, the objectives of this study are: to assess the relationship between MP and VR and to compare the components of MP (ventilatory variables) according to a level of MP (17 J/minute) considered harmful.


Clinical Trial Description

In patients with acute respiratory distress syndrome (ARDS), mechanical ventilation is a life support therapy; however, its use is associated with ventilator-induced lung injury (VILI). VILI is the final manifestation of changes in lung mechanics that occurs in each ventilatory cycle in a damaged lung parenchyma. In each respiratory cycle, a certain amount of mechanical energy is transferred to the lung, which is used primarily to overcome airway resistance and expand the chest wall.This mechanical energy multiplied by the respiratory rate (RR) is what is known as mechanical power (MP), which reflects the amount of energy applied to the respiratory system per minute during mechanical ventilation (MV). The amount of energy transferred from the ventilator to the patient is measured in joules (J), while MP is defined as the amount of energy transferred per unit of time (J/minute). MP is a summary variable that includes: tidal volume (TV), RR, flow, positive end-expiratory pressure (PEEP) and driving pressure (difference between plateau pressure and PEEP). An experimental study showed that the increase in MP, through the increase in RR, was associated with VILI. There is also evidence that MP can predict the risk of mortality in mechanically ventilated patients with and without ARDS. In addition, a constant increase in the risk of death has been found with MP greater than 17.0 J/min. In turn, since this value could vary according to lung size, it has been proposed that MP normalized to lung size (assessed through lung compliance) may have better performance. One way to optimize the MP would be to limit the RR and TV. However, the decrease in any of these ventilatory variables can lead to inefficient ventilation and an increase in the arterial pressure of carbon dioxide (PaCO2). In recent years, the ventilatory ratio (VR) has been assessed. VR is a unitless ratio that it can be easily calculated using routine bedside variables. Its value reflects the ability of the lungs to excrete CO2 adequately. Higher values of VR were associated with higher pulmonary dead space and with mortality. In the ventilatory setting, the optimization of MP would lead to an increase in VR.In addition, and since the components of MP contribute unequally to its value, it would be important to be able to establish the variables that could be decisive in the ventilatory setting. For this reason, the primary outcome is to assess the relationship between PM and VR. The secondary outcomes are: to estimate the relationship between PM in relation to static compliance (PM/C) and VR, and to assess the differences in respiratory variables considering a MP of 17 J/min as cut-off point. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05761626
Study type Observational
Source Ramos Mejía Hospital
Contact
Status Completed
Phase
Start date March 1, 2016
Completion date February 10, 2023

See also
  Status Clinical Trial Phase
Completed NCT04384445 - Zofin (Organicell Flow) for Patients With COVID-19 Phase 1/Phase 2
Recruiting NCT05535543 - Change in the Phase III Slope of the Volumetric Capnography by Prone Positioning in Acute Respiratory Distress Syndrome
Completed NCT04695392 - Restore Resilience in Critically Ill Children N/A
Terminated NCT04972318 - Two Different Ventilatory Strategies in Acute Respiratory Distress Syndrome Due to Community-acquired Pneumonia N/A
Completed NCT04534569 - Expert Panel Statement for the Respiratory Management of COVID-19 Related Acute Respiratory Failure (C-ARF)
Completed NCT04078984 - Driving Pressure as a Predictor of Mechanical Ventilation Weaning Time on Post-ARDS Patients in Pressure Support Ventilation.
Completed NCT04451291 - Study of Decidual Stromal Cells to Treat COVID-19 Respiratory Failure N/A
Not yet recruiting NCT06254313 - The Role of Cxcr4Hi neutrOPhils in InflueNza
Not yet recruiting NCT04798716 - The Use of Exosomes for the Treatment of Acute Respiratory Distress Syndrome or Novel Coronavirus Pneumonia Caused by COVID-19 Phase 1/Phase 2
Withdrawn NCT04909879 - Study of Allogeneic Adipose-Derived Mesenchymal Stem Cells for Non-COVID-19 Acute Respiratory Distress Syndrome Phase 2
Not yet recruiting NCT02881385 - Effects on Respiratory Patterns and Patient-ventilator Synchrony Using Pressure Support Ventilation N/A
Terminated NCT02867228 - Noninvasive Estimation of Work of Breathing N/A
Completed NCT02545621 - A Role for RAGE/TXNIP/Inflammasome Axis in Alveolar Macrophage Activation During ARDS (RIAMA): a Proof-of-concept Clinical Study
Withdrawn NCT02253667 - Palliative Use of High-flow Oxygen Nasal Cannula in End-of-life Lung Disease Patients N/A
Completed NCT02232841 - Electrical Impedance Imaging of Patients on Mechanical Ventilation N/A
Completed NCT01504893 - Very Low Tidal Volume vs Conventional Ventilatory Strategy for One-lung Ventilation in Thoracic Anesthesia N/A
Withdrawn NCT01927237 - Pulmonary Vascular Effects of Respiratory Rate & Carbon Dioxide N/A
Completed NCT02889770 - Dead Space Monitoring With Volumetric Capnography in ARDS Patients N/A
Completed NCT02814994 - Respiratory System Compliance Guided VT in Moderate to Severe ARDS Patients N/A
Completed NCT01680783 - Non-Invasive Ventilation Via a Helmet Device for Patients Respiratory Failure N/A