View clinical trials related to Osteoarthritis.
Filter by:This is an international, single arm, multicenter, prospective, non-significant risk, Post-Market Clinical Follow-up (PMCF) study. Data will be collected for the commercially available AEQUALIS FLEX REVIVE shoulder system in both the anatomic and reversed configurations. The purpose of this study is to collect data needed to satisfy the European Union (EU) Medical Device Regulation (MDR) clinical post-market surveillance (PMS) and reporting requirements, and to support future regulatory submissions and peer-reviewed publications on device performance and safety.
The purpose of this study is to evaluate the effect of a 12 week digital treatment program for patients with hand osteoarthritis. The treatment consisted of exercises and educational sessions with respect to the disease, its natural course and recommended treatment strategies. Design: An observational longitudinal cohort study. The investigators will include participants who participated in the digital treatment of Joint Academy® for 3 months. Outcomes: Investigators will analyze pain with Numeric Rating Scale (NRS) 0-10 (best to worst), function with the Functional Index for Hand OsteoArthritis (FIHOA) and HRQL with EQ-5D-5L at baseline and at 3 months. Main outcome will be change in pain. The investigators will also analyze minimally clinical important changes (improved or not) and mean changes in EQ-5D-5L index score, pain and function.
The aim of the study is to examine the effectiveness of arthrocentesis plus tenoxicam injection and to compare it with arthrocentesis alone in patients with TMJ-OA. Thirty patients with TMJ-OA who were treated randomly with either arthrocentesis plus tenoxicam injection (TX group) or arthrocentesis alone (control group) were examined. Maximum mouth opening (MMO), visual analog scale (VAS) pain values, and joint sounds were the outcome variables, which were evaluated at pre-treatment and at 1, 4, 12, and 24 weeks after treatment.
The aim of the study is to compare the efficacy up to 12 months of two different types of PRP (PRP with leukocytes vs PRP depleted of leukocytes) in the echo-guided infiltrative treatment of hip OA by including 230 patients in the study and evaluating them through subjective (using the WOMAC score as the primary outcome) and objective clinical scores.
A First-in-Human, Double-blind, Randomized, Placebo-controlled, Single Ascending Dose Study to Evaluate Safety, Tolerability, Pharmacokinetics/Pharmacodynamics of iN1011-N17 after Oral Administration in Healthy Volunteers.
The registry will capture prospective data on patients receiving pain management for chronic pain due to knee osteoarthritis (OA) or pain optimization for knee arthroplasty due to knee OA. The OA pain therapies may include cryo nerve block, radiofrequency ablation (RFA), intra-articular (IA) corticosteroids, viscosupplementation, opioids, and others (e.g., non-steroidal anti-inflammatory drugs [NSAIDs]).
This study is a 3-arm, double-blind, randomized trial comparing the clinical outcomes of Zilretta, Synvisc One, and Monovisc for knee OA.
The purpose of this trial is to determine if radiofrequency ablation plus steroid perineural injections at the knee or hip provide longer pain relief and better function to patients than the current standard of care, perineural steroid injections alone. This pilot study is a prospective two arm randomized trail, all participants will be recruited from the University of Texas Southwestern Medical Center (UTSW) outpatient orthopedic clinic. 40 participants (20 hip and 20 knee OA) will be enrolled into the standard of care arm (treated with steroid injections alone) and 40 participants (20 hip and 20 knee OA) will be enrolled into the investigational arm (treatment with a combination of radiofrequency ablation (RFA) plus steroid injections) for a total of 80 enrolled participants. All subjects will complete a function and pain assessment at the time of injection and three additional time points: 2 weeks, 3 months, and 6 months post injection. This study will use the same knee function questionnaire and frequency currently used in clinic per standard of care. In addition, all participant's surgical history and prior injection history will be reviewed via the Electronic Medical Record (EMR).
There are many factors that can influence patient satisfaction and patient related outcomes following total knee replacement including the surgical alignment of the joint components. Historically, total knee replacements have been performed with an aim aiming to achieve neutral alignment or a mechanical weight axis in the lower extremity . However, only 0.1 % of the population have a pre-surgical anatomical neutral alignment, and therefore the constitutional anatomy of the patient is neglected. There is a growing trend to return patients back their anatomical constitutional alignment after a knee replacement, referred to as Kinematic Alignment using robotics. The aim of this randomized controlled trial is to examine how mechanical alignment and kinematic alignment impacts function, pain, mood and fatigue following TKR for the treatment of osteoarthritis. Outcomes will be measured at 6 week, 6 months, 1 year and 2 years after surgery.
Osteoarthritis (OA) is the most common joint disease. It is characterized by a progressive destruction of all the components of the joint, especially the cartilage. This leads to pain, loss of mobility and can be a major handicap for some patients. Gonarthrosis, or osteoarthritis of the knee, affects 30% of people between the ages of 65 and 75 and is one of the most disabling conditions. In the final stage, the only therapeutic option to relieve patients is to replace the joint with a total knee prosthesis. Thanks to the contribution of an evaluation technique based on inertial sensors (X-SENS device), our objective is to better evaluate and understand the movement deficit in knee OA subjects. The hypothesis is that, thanks to the contribution of a technique based on inertial sensors (X-SENS), the investigators can better evaluate the movement deficit of knee OA subjects. The goal is to propose specific, rapid telekinetic biomarkers, allowing a better evaluation of functional improvements following therapeutic interventions, such as a total knee replacement.